34-163-20851

Well Details

Well ID: 34-163-20851
Loading map...
Country: United States
State: Ohio
County: Vinton
Municipality: Knox Township
Operator Name: BANCEQUITY PETROLEUM CORPORATI
Well Pad ID:
Farm/Lease Name: STANEART CECIL
License Status: Active Injection
License Date: 1995-08-08
Spud Date: 1984-10-05
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1984-10-13
Well Total Depth: 1500.00 ft
Configuration: Vertical
Latitude: 39.210000
Longitude: -82.290000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-08-23 Issued Date 8/23/84 Expired Date 12/28/85 Acres 0172000 Tool Type CRF Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1984-10-05 CONVERT 7-6-85, RI 9-6-86, RI 8-12-95, LOG TYPE =SB PERMIT EXPIRED.
Completed 1984-10-13 CONVERT 7-6-85, RI 9-6-86, RI 8-12-95, LOG TYPE =SB PERMIT EXPIRED.
Reached Total Depth 1984-10-13 CONVERT 7-6-85, RI 9-6-86, RI 8-12-95, LOG TYPE =SB PERMIT EXPIRED.
CO 1984-12-07 566 GRIM PAUL A GeoDate 8/23/84
First Injection 1984-12-07 CONVERT 7-6-85, RI 9-6-86, RI 8-12-95, LOG TYPE =SB PERMIT EXPIRED.
Completion Report Received 1985-03-26 CONVERT 7-6-85, RI 9-6-86, RI 8-12-95, LOG TYPE =SB PERMIT EXPIRED.
CO 1985-07-02 566 GRIM PAUL A GeoDate 7/2/85
Enhanced Recovery 1985-07-02 Issued Date 7/2/85 Expired Date 12/28/85 Acres 0172000 Tool Type NT Proposed Formation BEREA Proposed Depth 01500 Proposed Drill Depth 01500
CO 1986-09-03 566 GRIM PAUL A GeoDate 9/3/86
Enhanced Recovery 1986-09-03 Issued Date 9/3/86 Expired Date 9/3/87 Acres 0172000 Tool Type NT Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
CO 1995-08-08 566 GRIM PAUL A GeoDate 8/8/95
Enhanced Recovery 1995-08-08 Issued Date 8/8/95 Expired Date 8/7/96 Acres 0172000 Tool Type RTAF Proposed Formation BEREA Proposed Depth Proposed Drill Depth
Annulus Pressure Monitoring Approved 1996-07-05 CONVERT 7-6-85, RI 9-6-86, RI 8-12-95, LOG TYPE =SB PERMIT EXPIRED.
Construction Permit Expires 1996-08-07 CONVERT 7-6-85, RI 9-6-86, RI 8-12-95, LOG TYPE =SB PERMIT EXPIRED.
Change of Owner 2001-11-21 Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP.
Change of Owner 2008-04-24 Operator changed from 5755, CHIEFTAIN ENERGY CORP to 566, GRIM PAUL A. THE TRANSFER OF THIS WELL IS PURSUANT TO JUDGEMENT ENTRY CASE # 04-CV06-062, VINTON COUNTY COURT OF COMMON PLEAS.
Change of Owner 2009-11-17 Operator changed from 566, GRIM PAUL A to 4801, BANCEQUITY PETROLEUM CORP
Change of Owner 2009-11-18 Operator changed from 4801, BANCEQUITY PETROLEUM CORP to 566, GRIM PAUL A
Change of Owner 2009-12-22 Operator changed from 566, GRIM PAUL A to 4801, BANCEQUITY PETROLEUM CORP
Last Compliance Report 2016-12-27 CONVERT 7-6-85, RI 9-6-86, RI 8-12-95, LOG TYPE =SB PERMIT EXPIRED.
Record Last Modified 2017-02-15 CONVERT 7-6-85, RI 9-6-86, RI 8-12-95, LOG TYPE =SB PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-04-21 1273 1275 1
2000-04-21 1265 1267 1
1287 1289 1
1295 1297 1
1265 1267 1
1273 1275 1
1265 1267 1
2000-04-21 1295 1297 1
2000-04-21 1287 1289 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 900 Bbl 0 ALSO FRAC WITH 15,000 LBS OF 20/50 SAND
H2O 0 0 0 & SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 GRIM PAUL A 0.00 2757.00 365
1986 GRIM PAUL A 0.00 1079.00 365
1987 GRIM PAUL A 0.00 742.00 365
1988 GRIM PAUL A 0.00 415.00 365
1989 GRIM PAUL A 0.00 364.00 365
1990 GRIM PAUL A 0.00 489.00 365
1991 GRIM PAUL A 0.00 506.00 365
1992 GRIM PAUL A 0.00 289.00 365
1993 GRIM PAUL A 0.00 328.00 365
1994 GRIM PAUL A 0.00 0.00 365
1995 GRIM PAUL A 0.00 26.00 365
1996 GRIM PAUL A 0.00 5.00 365
1997 GRIM PAUL A 0.00 0.00 365
1998 GRIM PAUL A 0.00 0.00 365
1999 GRIM PAUL A 0.00 0.00 365
2000 GRIM PAUL A 0.00 0.00 365
2001 GRIM PAUL A 0.00 0.00 365
2010 BANCEQUITY PETROLEUM CORPORATI 300.00 180.00 276

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 GRIM PAUL A Brine 9246 365
1986 GRIM PAUL A Brine 7338 365
1987 GRIM PAUL A Brine 6972 365
1988 GRIM PAUL A Brine 3952 365
1989 GRIM PAUL A Brine 4260 365
1990 GRIM PAUL A Brine 1552 365
1991 GRIM PAUL A Brine 5949 365
1992 GRIM PAUL A Brine 1464 365
1993 GRIM PAUL A Brine 2058 365
1994 GRIM PAUL A Brine 0 365
1995 GRIM PAUL A Brine 120 365
1996 GRIM PAUL A Brine 22 365
1997 GRIM PAUL A Brine 0 365
1998 GRIM PAUL A Brine 0 365
1999 GRIM PAUL A Brine 0 365
2000 GRIM PAUL A Brine 0 365
2001 GRIM PAUL A Brine 0 365
2010 BANCEQUITY PETROLEUM CORPORATI Brine 0 276

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1004587284 2007-4-19 0:00: ER No Violations
-1060900448 2015-3-11 0:00: ER No Violations 3.00
-1070907701 2011-8-22 0:00: ER No Violations
-1072674992 2017-7-18 0:00: SW No Violations 0.30
-1093233553 2016-6-9 0:00:0 ER No Violations 1.00
-1094288967 2013-1-31 0:00: ER No Violations 2.50
-1109441491 2007-2-23 0:00: ER No Violations
-1145219615 2015-3-12 0:00: ER No Violations 2.00
-1149968042 2016-12-21 0:00 ER No Violations 2.00
-1259341673 2010-7-8 0:00:0 ER No Violations
-1264405392 2014-4-1 0:00:0 ER No Violations 1.50
-1430028308 2020-3-5 0:00:0 ER No Violations 2.00
-1471675568 2011-12-13 0:00 ER No Violations 2.00
-1505216398 2010-9-22 0:00: ER No Violations 1.50
-1539432295 2005-10-20 0:00 ER No Violations
-155790919 2017-6-1 0:00:0 SW No Violations
-1564485034 2015-3-16 0:00: ER No Violations 0.50
-1578701942 2019-8-26 0:00: ER No Violations 1.00
-1589878603 2015-10-15 0:00 ER No Violations 1.00
-170666187 2006-12-22 0:00 ER No Violations
-171011986 2018-6-25 0:00: ER No Violations 4.00
-171069950 2011-12-13 0:00 ER No Violations
-1748057626 2013-9-9 0:00:0 ER No Violations 2.50
-1927237363 2008-2-21 0:00: ER No Violations
-1963747237 2007-1-18 0:00: ER No Violations
-2025182201 2018-5-11 0:00: ER No Violations 4.30
-241700543 2018-5-17 0:00: ER No Violations 2.90
-263216073 2018-6-5 0:00:0 ER No Violations 2.50
-286782332 2009-6-11 0:00: ER No Violations
-445360881 2005-4-7 0:00:0 ER No Violations
-607523155 2014-3-10 0:00: ER No Violations 2.00
-616292266 2007-11-1 0:00: ER No Violations
-642077879 2011-4-14 0:00: ER No Violations
-725259960 2008-9-11 0:00: ER No Violations
-742057710 2014-3-10 0:00: ER No Violations 2.00
-754663736 2012-1-17 0:00: ER No Violations 1.00
-824130364 2008-12-22 0:00 ER No Violations
0000001102 2002-06-05 Enhanced Recovery Project No Violations Follow-up on NOV, Non-Compliance. Done a mini test on well, well passed test, all other violations not corrected.
0000PL2258 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0000UIC592 1989-01-17 Enhanced Recovery Project No Violations 1502.22 (C)(1)(2)(3) Storage & Disp.
0000UIC593 1989-01-17 Enhanced Recovery Project No Violations 1501:9-5-06 Prevent cont. & Pol
0000UIC594 1989-01-17 Enhanced Recovery Project No Violations 1501:9-5-09 (A)(6) Stor.facility const.
001269i755 2002-02-06 Enhanced Recovery Project Violations Noted An inspection revealed that the violations have not been corrected by Paul Grim, now Chieftain Energy owns wells. No ID at the well or tanks, contaminated soil around and below dike of tank battery, dike walls leaking allowing brine and fluids to flow from dike. Lease road has erosion and eroding into creek. Need full ID at well and tank battery, contaminated soil needs cleaned up, dike wall needs repaired to prevent fluids from escaping. Lease road needs graded and water breaks put in. MIT test needs done on injection well, call inspector of time and date.
0018843039 2018-10-02 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. There is no new vegetative growth in the remediated area outside of the containment dike.
005609i106 2001-03-22 Enhanced Recovery Project Violations Noted An inspection of the well and tanks revealed that there are several cracks in the wall of the dike around the brine storage tanks and pump , allowing brine and oil to escape from the dike . A contaminated area below dike approx. 20ft by 30ft . No ID at well or tanks .
005609i193 2001-05-03 Enhanced Recovery Project No Violations Follow - up on NOV , Non - Complaince , cracks still in wall of dike and brine running onto the ground. No ID at well head or tank battery.
005609i226 2001-06-08 Enhanced Recovery Project No Violations An inspection revealed that the wall of the dike is still leaking brine and contaminating the area around and below the dike.
0063284309 2013-01-25 Enhanced Recovery Project No Violations I accompanied Andy Thomas on the inspection of this well.
0071478583 2014-07-01 Enhanced Recovery Project Violations Noted Inspected containment dike, tanks, injection pump, injection line, annulus pressure and injection pressure. Identification posted on tank and at well. A 2 by 5 bare area was observed outside the dike. A high end Quantab was placed is a small depression with in the bare area. The Quantab recorded 6.8 (2050 ppm Cl). The containment dike had 1 inch of water in the dike (from a recent rain event) just opposite of the bare area. The water in the containment dike was 1.2 on the high end Quantab. I called mike McPeak and we discussed the need to remediate the bare area and to keep the containment dike free of water.
01269i1012 2002-05-06 Enhanced Recovery Project No Violations Follow-up on Chiefs Order, company has not complied with NOV or Chiefs Order, have not tested well for injection, dike area still leaking, no ID at the well or tanks.
01269i1310 2002-08-20 Enhanced Recovery Project No Violations Follow - up on NOV, Non-Compliance, dike wall around storage tanks still leaking aloowing fluids to escape from dike. Cracks in dike wall have not been repaired. Kill areas behind and below dike, kill area approx. 25ft x 30ft. Oil and water standing in dike. ID on storage tank, none on well head.
01269i1558 2002-11-25 Enhanced Recovery Project No Violations Follow-up on NOV, In-Compliance.
0141518339 2017-12-14 Salt Water Injection Well No Violations My inspection revealed the salt water injection well had 285 psi on the injection tubing and the annulus had 84 psi. The containment dike was free of fluids. Legible identification was posted.
0148179719 2007-12-26 Enhanced Recovery Project No Violations A follow-up inspection revealed that the previously noted violations have been resolved.
0155790919 2017-06-01 Salt Water Injection Well No Violations Salt water injection well inspection. The injection pressure was 49 PSI, the annulus pressure was 120 PSI. No violations noted.
0170666187 2006-12-22 Enhanced Recovery Project No Violations On 12/22/2006, Mr. Brent Bear, Mineral Resources Inspector, met with Mr. Doug Kitchen and Mr. Ron McBride, Chieftain Energy to perform a MIT test and pump fluid from the dike. Mr. Kitchens had coordinated this meeting with the landowner and Mr. Kitchens attorney, due to a restraining order that is in effect. The landowner failed to show after 1.5hrs to unlock the gate. As a result, another date will have to be set to resolve the violations. Mr. Kitchen was instructed to schedule another date immediately.
0171011986 2018-06-25 Enhanced Recovery Project No Violations Compliance Notice # 202518221 follow up inspection. Vegetative growth has been established on the remediated area. Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
0171069950 2011-12-13 Enhanced Recovery Project Violations Noted Accompanied by Andy Thomas MRI. Dike has cracks in concrete and is leaking brine. Vegetative scald area 4 by 10. Zero pressure on annulus. Andy called pumper and scheduled a mini test of the annulus and discussed the dike repairs that are needed.
0241700543 2018-05-17 Enhanced Recovery Project No Violations Compliance notice # 2025182201 follow up inspection. The scald area has been covered with soil excavated North West of the well. I talked to Jess Hess on site. Jess stated that they scraped the contaminated soil and hauled it to their yard. The new soil was placed over the excavated area with lime, fertilizer and grass seed applied to the location.
0254729152 2016-02-22 Enhanced Recovery Project No Violations inspected the containment dike, tanks, injection pump, injection line, injection pressure, and annulus pressure. Identification posted at well. Dike is free of water.
0263216073 2018-06-05 Enhanced Recovery Project No Violations Compliance Notice # 2025182201 follow up inspection. Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. Vegetative cover has not been established on the remediation area. The 2 inch injection tubing collar has salt build up on the outside of the tubing. I called Mike McPeak on 6-5-2018 at 2:36 pm, and told him that the remediation needs more effort to achieve vegetative cover. I also informed him about the salt build up on the injection tubing collar.
0286782332 2009-06-11 Enhanced Recovery Project No Violations An inspection revealed that the status remains the same. Court Case still pending between the landowner and company. RBDMS shows Mr. Paul Grim as the well owner. The displayed identification will need to show Mr. Grim instead of Chieftain Energy. The well is not being utilized at this time. 0 psi observed on both annulus and injection side of the well.
0445360881 2005-04-07 Enhanced Recovery Project Violations Noted An inspection of the well revealed no pressure on the injection side or annular side of well, no ID at the well.
0530149472 2015-08-10 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Assisted UIC section Geologist in measuring the containment dike.
0569182074 2009-03-03 Enhanced Recovery Project No Violations An inspection revealed that the status of this well has not changed.
0599298646 2011-03-29 Enhanced Recovery Project No Violations Annulus had zero pressure. I talked to Jess Hess and they are going to schedule a test.
0607523155 2014-03-10 Enhanced Recovery Project No Violations FOLLOW UP TO NOV # -742057710 Inspected containment dike, tanks, injection pump, injection line, injection pressure, and annulus pressure. Containment dike wall has cracks that need to be repaired. The containment dike is constructed of poured concrete. I called Mike McPeak and we discussed the dike condition. Mike was aware of the cracks and told me that they can repair the containment with in two weeks.
0616292266 2007-11-01 Enhanced Recovery Project No Violations An inspection revealed non-compliance.
0642077879 2011-04-14 Enhanced Recovery Project No Violations Witnessed mini test of the annulus. Tested at 350 psi for 15 minutes. 340 psi after 15 minutes. Mini test passed.
0667045693 2005-06-08 Enhanced Recovery Project No Violations No violations.
0725259960 2008-09-11 Enhanced Recovery Project No Violations A follow-up inspection revealed no pressure on the annulus. This well is not in operation at this time, due to a legal dispute.
0742057710 2014-03-10 Enhanced Recovery Project No Violations Inspected containment dike, tanks, injection pump, injection line, injection pressure, and annulus pressure. Containment dike wall has cracks that need to be repaired. The containment dike is constructed of poured concrete. I called Mike McPeak and we discussed the dike condition. Mike was aware of the cracks and told me that they can repair the containment with in two weeks.
0754663736 2012-01-17 Enhanced Recovery Project No Violations Conducted follow up inspection on tank battery. Cracks had not yet been sealed in the concrete containment system. Called Mike McPeak and left a voicemail on his phone. Accompanied by Inspector Kip Thompson.
0824130364 2008-12-22 Enhanced Recovery Project No Violations An inspection revealed that the well status has not changed since the last inspection. No annulus or injection pressure was observed. The concrete dike placed around the storage tanks is beginning to crack along the backside. A bare area approximately 5x 10 was observed below this location.
0927781947 2013-07-29 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure, and annulus pressure. Water in dike goes from 0-4. Injection pump location has been moved with-in the dike. The scald area outside the dike is in need of more work. I called Mike McPeak and we discussed the need to keep the dike free of water and to remediate the scald area. Mike agreed to pump out the dike and to till up the scald area and apply lime, fertilizer, grass seed and mulch.
0959914402 2016-07-29 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted. The containment dike is free of fluids.
0992304943 2004-03-04 Enhanced Recovery Project No Violations No violations.
1004587284 2007-04-19 Enhanced Recovery Project Violations Noted An inspection conducted on 4/19/2007 revealed no pressure on the annulus side of the well. A valve was observed to be open, in which the pressure appears to have been released.
1005407707 2012-06-14 Enhanced Recovery Project No Violations Good identification was observed at the well site. No leaks were observed at the well head or tank battery. Where the concrete containment dike was sealed is proving effective.
1024332125 2019-11-6 0:00: ER No Violations 1.00
1060900448 2015-03-11 Enhanced Recovery Project Violations Noted Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Containment dike was full of oil and water up to three inches from the top of the dike wall. The containment sump pump was in operation during the inspection and the fluid level did decrease approximately 1 inch during the inspection. The 100 barrel steel tank appears to have over flowed oil into the dike. I was unable to close the 1/4 valve on the injection tubing, so the company pressure gauge was re tightened. I was unable to open the 2 valve on the annulus. 20 psi was observed between the 2 valve and the 1/4 valve on the annulus. I called Mike McPeak at 1:51 pm and left a message outlining the need to continue to remove the fluids from the containment dike and that the 1/4 injection tubing valve needs replaced along with the 2 annulus valve. I called at 5:34pm and talked to Mike McPeak and we reviewed the dike clean up efforts and the need to replace the injection tubing valve and the annulus valve so that the pressures can be monitored.
1070907701 2011-08-22 Enhanced Recovery Project No Violations No violations observed during inspection.
1072674992 2017-07-18 Salt Water Injection Well No Violations Quarterly UIC inspection. The annulus pressure was 150 PSI, the injection tubing was 142 PSI. Legible identification was posted. No violations noted.
1093233553 2016-06-09 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted. Containment dike was free of fluids.
1094288967 2013-01-31 Enhanced Recovery Project No Violations The gauge on the annulus had 125 psi on it with both valves closed. No violations were noted. Conditions were very cold.
1102 2002-6-5 0:00:0 ER No Violations
1109441491 2007-02-23 Enhanced Recovery Project No Violations A follow-up inspection revealed that the dike has been repaired. The previously noted violation has been resolved.
1145219615 2015-03-12 Enhanced Recovery Project No Violations Bancequity crew is repairing the pump in order to remove the fluids from the dike.
1149968042 2016-12-21 Enhanced Recovery Project No Violations Mechanical Integrity Test. Tested the annulus at 390 psi, at 5 minutes 390 psi, at 15 minutes 390 psi.
1155064470 2006-07-31 Enhanced Recovery Project Violations Noted An inspection was conducted at the facility owned by Chieftain Energy Corp on 7/31/2006. During the inspection, it was noted that a mini test will be required. No pressure was found at either the injection or annulus side of the well. The dike for this facility will need to be repaired and liquid pumped out. Also noted was that identification is needed at the storage tanks. The owner, Mr, Doug Kitchen was verbally instructed of the deficiencies found during the inspection.
1157372001 2018-09-07 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. The previous remediated areas outside of the containment do not have vegetation on them. I contacted Mike McPeak and told him the Cecil Staneart 6 still needs remediation. Remove the soil and haul to an EPA approved landfill. Establish vegetative cover.
1251981195 2012-08-30 Enhanced Recovery Project No Violations No violations noted at the time of inspection.
1259341673 2010-07-08 Enhanced Recovery Project No Violations An inspection revealed no violations at this time. Notable changes were observed on this lease since the last inspection. At the entrance into the lease, on right hand side, the four 100 bbl tanks equipped for transfer to injection facility now contain an earthen dike. The injection facility contains an additional 100 bbl tank (painted black) placed inside concrete dike. A replacement pump appears to have also been installed at the facility.
1264405392 2014-04-01 Enhanced Recovery Project No Violations Compliance notice follow-up. Containment dike wall has been repaired. Damaged section of the dike wall was removed and new concrete was poured to make the containment dike whole. The injection pump has been replaced. Identification is posted.
1269i1012 2002-5-6 0:00:0 ER No Violations
1269i1310 2002-8-20 0:00: ER No Violations
1269i1558 2002-11-25 0:00 ER No Violations
1269i755 2002-2-6 0:00:0 ER No Violations
1269i87356 2002-03-14 Enhanced Recovery Project No Violations Follow-up on NOV, Non-Compliance, company has not complied with the NOV, no ID at well and tanks, dike walls leaking brine and oil, lease rd. still eroding, M.I.T. test not done on well, called Columbus and requested an Order be issued on this well to shut down well operations. COMPANY DID NOT SHOW UP FOR 2:00 PM MEETING, LEFT AT 2:30 PM.
1269i87356894 2002-3-14 0:00: ER No Violations
1279935717 2016-10-12 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
1293569517 2010-12-28 Enhanced Recovery Project No Violations An inspection revealed no violations. Snow cover at time of inspection.
1325247741 2011-12-22 Enhanced Recovery Project No Violations Witnessed mini-test on the annulus of this well. Test started at 10:30 am at 340 psi., and ended at 10:45 at 340 psi.
1331195321 2018-03-22 Salt Water Injection Well No Violations The salt water injection well had 75 psi on the annulus and 125 psi on the injection tubing. The dike was relativity free of fluids. Legible identification was posted.
1369410476 2013-05-20 Enhanced Recovery Project Violations Noted Inspected the injection pressure, annulus pressure, containment dike and tanks. Concrete dike has 4 of water in it. Dike has a seep with an associated scald area approximately 3 by 10. I called and talked to Mike McPeak about the dike condition. I told Mike to pump the water out of the dike and into a tank. Seal the dike. Remediate the scald area.
1380710429 2013-08-05 Enhanced Recovery Project No Violations Dike is free of water. Scald area out side dike has been tilled up with lime and fertilizer applied. Seed and straw have been applied to location. No vegetative growth on the scald site.
1385792811 2019-01-28 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. Vegetative cover has been established down slope of the containment dike.
1408564513 2014-08-20 Enhanced Recovery Project No Violations Compliance Notice # 71478583 Follow up. Inspected the containment dike, tanks, injection pump, injection line, annulus pressure and injection pressure. Scald area outside the containment dike is 30 by 60. Containment dike is free of water. I called Mike McPeak and left a message about the need to remediate the scald area. I requested a time frame for completion of the remediation.
1410789174 2014-09-15 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, annulus pressure and injection pressure. Identification posted near well on post. Bare area outside containment dike has been remediated. Site has been seeded with mulch applied. Vegetative growth has started to establish on affected area.
1412256613 2014-10-02 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, annulus pressure and injection pressure. Identification posted at well and on a tank in the containment dike.
141518339 2017-12-14 0:00 SW No Violations 1.00
1426191458 2015-03-12 Enhanced Recovery Project Violations Noted Follow up inspection of the surface facility revealed that the oil and water had not been removed from the containment dike. The containment dike sump pump was turned off. Two brine seeps and scald areas were observed down slope, South of the surface facility containment dike. 1st measured 6 feet by 6 feet, 2nd measured 21 feet by 3 feet. High Range Quantabs were used to determine the extent of the contaminated area. Both scald areas exceeded 6078 ppm Cl (mg/L). All Fluids in the containment dike must be removed and placed in tanks. The containment dike must be water tight. Repair or replace the containment dike so that it is water tight. Remove all contaminated soils and take them to an EPA approved land fill. Remediate the contaminated areas.
1426790870 2015-03-19 Enhanced Recovery Project No Violations Containment dike is free of oil and water. A crack in the containment dike wall has been repaired. The brine seep and scald areas out side of the containment dike have been tilled up and lime has been applied to the disturbed area.
1471675568 2011-12-13 Enhanced Recovery Project No Violations Accompanied Jon Scott on inspection. Request mini test from Mike McPeak on this well. Mini test performed on 12/22/2011. Test was started at 10:30 am at 330 psi. Test ended at 10:45 am at 330 psi. No pressure loss.
148179719 2007-12-26 0:00 ER No Violations
1492613692 2017-04-10 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted. The containment dike is free of fluids.
1505216398 2010-09-22 Enhanced Recovery Project No Violations An inspection revealed no violations. Note: The gauge utilized for this inspection will require calibration.
1522755219 2014-05-21 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, annulus pressure, and injection pressure. Good identification posted on tank in containment dike. Annulus pressure on vacuum. I called Mike McPeak and told him that the annulus was on vacuum and that they must stop injection until the annulus is tested. Mike told me that they will be at the well to test the annulus today. The annulus was filled with one gallon of fresh water and pressured up to 300 psi for a mini test. Annulus held 300 psi for 15 minutes.
1539432295 2005-10-20 Enhanced Recovery Project Violations Noted FAILURE TO SUBMIT ANNUAL ENHANCED RECOVERY INJECTION WELL REPORT FOR 2004
1564485034 2015-03-16 Enhanced Recovery Project No Violations Compliance notice follow up. Bancequity crew is on site and is working on removing the oil from the sump pit.
1589878603 2015-10-15 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted between well and dike. Containment dike is free of fluids.
1625721807 2009-12-09 Enhanced Recovery Project No Violations An inspection revealed no injection at this time. The well status remains the same as previous inspection, no observed pressures and/or vacuum. New identification has been placed at the well showing Bancequity as the new well owner. At this time, RBDMS shows Paul Grim is still the well owner.
1748057626 2013-09-09 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Good identification at the wellhead. Vegetation has been established on the scald area.
1808648793 2013-01-24 Enhanced Recovery Project Violations Noted A visual inspection of the facility revealed no violations. When checking the pressures on the annulus and the injection tubing, I noticed that the annulus pressure was 0 and the injection was on vacuum. There are no other violations at this facility. I called Mr. Mike McPeak at 12:52 PM and told him that the pressure on the annulus needs to be above 0. He stated that he would go and pressure up on it later today. I will check the pressure again on 1/28/13. Accompanied on inspection by Justin Smith.
1876513591 2004-06-10 Enhanced Recovery Project No Violations Non-compliance, met with JoeHoerst, Dave Hodges, and Doug Kitchen and his attorney to review violations at well site.
18843039 2018-10-2 0:00: ER No Violations 0.70
1916987448 2010-03-17 Enhanced Recovery Project No Violations An inspection revealed no violations at this time. During the inspection, it was noted that the new well owner continues to perform work on EOR well. New 2 black plastic line has been installed on storage tank bottoms, new electric motor, identification displayed, filters connected along with injection line. The storage tanks have now been painted black. At the location, a company representative stated that the well passed their mini-test with a 12 lb loss at 300 psi. They found that pressure is bleeding off around the stripping rubbers. Note: additional work performed on this lease include installation of (4) 100 bbl tanks at entrance.
1927237363 2008-02-21 Enhanced Recovery Project Violations Noted An inspection revealed no positive pressure on the annulus.
1941811368 2009-09-01 Enhanced Recovery Project No Violations An inspection was conducted with Mr. Jeff Fry, West Region Oil & Gas Supervisor and UIC Field Supervisor. During the inspection, it was noted that the status remains the same. No injection of annulus pressure was observed. The displayed identification will need to be changed from Cheiftain Energy to Paul Grim.
1963747237 2007-01-18 Enhanced Recovery Project No Violations A mini-test was conducted on 1/18/2007. The well passed the required test. The dike was pumped however, the dike will need repaired to prevent leakage. Cracks were observed along the backside of the dike. The owner, Mr. Doug Kitchen, was instructed to make the necessary repairs.
1990434176 2015-05-21 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Good identification posted. Containment dike free of fluids.
2025182201 2018-05-11 Enhanced Recovery Project Violations Noted Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. A brine scald area with oil residue was observed at the south east corner of the dike. The scald area is 30 feet by 5 feet. I Called Mike McPeak we discussed the scald area and the remediation of the site. Contaminated soil must be removed and hauled to an EPA approved landfill. Must establish vegetative growth on the remediated site.
2107390775 2006-09-20 Enhanced Recovery Project No Violations A follow-up inspection was conducted at the facility owned by Chieftain Energy Corp., on 9/20/2006. During the inspection, it was noted that the previously noted violations have not been resolved. The owner, Mr. Doug Kitchen was contacted by telephone and instructed to resolve deficiencies.
254729152 2016-2-22 0:00: ER No Violations 1.00
373717666 2019-4-30 0:00: ER No Violations 2.70
530149472 2015-8-10 0:00: ER No Violations 0.70
5609i106 2001-3-22 0:00: ER No Violations
5609i193 2001-5-3 0:00:0 ER No Violations
5609i226 2001-6-8 0:00:0 ER No Violations
569182074 2009-3-3 0:00:0 ER No Violations
599298646 2011-3-29 0:00: ER No Violations
63284309 2013-1-25 0:00: ER No Violations
667045693 2005-6-8 0:00:0 ER No Violations
71478583 2014-7-1 0:00:0 ER No Violations 1.50
727986061 2020-4-16 0:00: ER No Violations 2.50
927781947 2013-7-29 0:00: ER No Violations 1.00
959914402 2016-7-29 0:00: ER No Violations 2.50
992304943 2004-3-4 0:00:0 ER No Violations
iTOMK00012 2001-03-22 Enhanced Recovery Project No Violations
iTOMK000123 2001-3-22 0:00: ER No Violations
PL2258 PL No Violations
UIC592 1989-1-17 0:00: ER No Violations
UIC593 1989-1-17 0:00: ER No Violations
UIC594 1989-1-17 0:00: ER No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
001269i755 US-OH-107269 2002-02-07 Pollution/Contamination
001269i755 US-OH-107270 2002-02-07 Contamination at storage facility (permit after 6/1/82)
001269i755 US-OH-107271 2002-02-07 Insufficient/No identification
005609i106 US-OH-126194 2001-03-22 Pollution/Contamination
005609i106 US-OH-126195 2001-03-22 Insufficient/No identification
005609i106 US-OH-126196 2001-03-22 Dike or pit not able to prevent escape of brine or other wastes
005609i106 US-OH-126197 2001-03-22 Unlawful use of pit for temporary storage of brine or other wastes
0071478583 US-OH-128115 2014-09-22 Pollution/Contamination
0171069950 US-OH-116958 2011-12-30 Contamination at storage facility (permit after 6/1/82)
0171069950 US-OH-116959 2011-12-30 Failure to monitor annulus pressure
0445360881 US-OH-124809 2005-04-11 Insufficient/No identification
1004587284 US-OH-100503 2007-04-23 Failure to monitor annulus pressure
1060900448 US-OH-101186 2015-03-26 Violation of injection tubing/fitting requirements
1060900448 US-OH-101187 2015-03-26 Contamination at storage facility (permit after 6/1/82)
1060900448 US-OH-101188 2015-03-26 Failure to monitor annulus pressure
1155064470 US-OH-104065 2006-08-08 Contamination at storage facility (permit after 6/1/82)
1155064470 US-OH-104066 2006-08-08 Failure to monitor annulus pressure
1155064470 US-OH-104067 2006-08-08 Insufficient/No identification
1155064470 US-OH-104068 2006-08-08 Failure to pass required test
1369410476 US-OH-110902 2014-04-23 Pollution/Contamination
1426191458 US-OH-112415 2015-03-26 Pollution/Contamination
1426191458 US-OH-112416 2015-03-26 Contamination at storage facility (permit after 6/1/82)
1539432295 US-OH-114874 2005-10-20 Failure to monitor pressures or volumes/failure to file
1808648793 US-OH-118068 2013-01-25 Failure to monitor annulus pressure
1927237363 US-OH-119394 2008-02-22 Failure to monitor annulus pressure
2025182201 US-OH-120595 2018-08-13 9-5-09(A)6 Contamination at storage facility (permit after 6/1/82)

For data sources see[9]