{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.22,"lon":-82.28,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Vinton | |
Municipality: Knox Township | |
Operator Name: BANCEQUITY PETROLEUM CORPORATI | |
Well Pad ID: | |
Farm/Lease Name: BECKLEY ETAL | |
License Status: Active Injection | |
License Date: 1986-03-20 | |
Spud Date: 1986-01-15 | |
Spud Drilling Contractor: R WOLFE DRLG | |
Final Drill Date: 1986-01-22 | |
Well Total Depth: 2710.00 ft | |
Configuration: Vertical | |
Latitude: 39.220000 | |
Longitude: -82.280000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1985-12-03 | Issued Date 12/3/85 Expired Date 12/3/86 Acres 0020000 Tool Type RTA Proposed Formation BIG LIME Proposed Depth 02710 Proposed Drill Depth 02710 |
Original Spud | 1986-01-15 | CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86 |
Completed | 1986-01-22 | CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86 |
Reached Total Depth | 1986-01-22 | CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86 |
CO | 1986-03-20 | 631 BT ENERGY CORP GeoDate 3/20/86 |
Conversion to Injector | 1986-03-20 | |
Salt Water Injection Well | 1986-03-20 | Issued Date 3/20/86 Expired Date 3/20/87 Acres 0020000 Tool Type RTA Proposed Formation ORISKANY Proposed Depth 02710 Proposed Drill Depth 02710 |
Storage Well | 1986-03-20 | Issued Date 3/20/86 Expired Date 3/20/87 Acres 0020000 Tool Type RTA Proposed Formation ORISKANY Proposed Depth 02710 Proposed Drill Depth 02710 |
First Injection | 1986-05-11 | CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86 |
CO | 1986-08-17 | 2338 CHARTOR ENERGY CORP GeoDate 12/3/85 |
Construction Permit Expires | 1987-03-20 | CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86 |
Completion Report Received | 1987-09-28 | CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86 |
Annulus Pressure Monitoring Approved | 1990-07-18 | CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86 |
CO | 1996-04-09 | 4801 BANCEQUITY PETROLEUM CORP GeoDate 3/20/86 |
Last Compliance Report | 2011-09-23 | CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86 |
Record Last Modified | 2017-10-19 | CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-09 | 2594 | 2606 | 2 |
2594 | 2606 | 2 | |
2594 | 2606 | 2 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 1000 Gal | 0 | FRAC: H2O,ACID CONVERT TO SWIW | ||
H2O | 0 | 130 Bbl | 0 | W/ADDITIVES. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | BANCEQUITY PETROLEUM CORPORATI | 0.00 | 913.00 | 365 |
1997 | BANCEQUITY PETROLEUM CORPORATI | 721.00 | 135.00 | 365 |
2000 | BANCEQUITY PETROLEUM CORPORATI | 472.00 | 15.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | BANCEQUITY PETROLEUM CORPORATI | Brine | 0 | 365 |
1997 | BANCEQUITY PETROLEUM CORPORATI | Brine | 0 | 365 |
2000 | BANCEQUITY PETROLEUM CORPORATI | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1085785738 | 2018-9-5 0:00:0 | SW | No Violations | 2.20 |
-1136427680 | 2009-3-2 0:00:0 | SW | No Violations | |
-1140001018 | 2016-8-9 0:00:0 | SW | No Violations | 2.00 |
-1168987590 | 2013-9-6 0:00:0 | SW | No Violations | 1.00 |
-118397305 | 2012-3-29 0:00: | SW | No Violations | |
-1187529685 | 2007-4-20 0:00: | SW | No Violations | |
-1217982588 | 2008-9-16 0:00: | SW | No Violations | |
-1273752688 | 2014-3-11 0:00: | SW | No Violations | 2.00 |
-1291330523 | 2020-6-1 0:00:0 | SW | No Violations | 2.70 |
-1332168620 | 2017-5-23 0:00: | SW | No Violations | 5.00 |
-1392961936 | 2014-3-11 0:00: | SW | No Violations | 2.00 |
-1396050688 | 2008-12-22 0:00 | SW | No Violations | |
-150443190 | 2011-8-13 0:00: | SW | No Violations | |
-1596230794 | 2007-7-3 0:00:0 | SW | No Violations | |
-1605749644 | 2011-8-4 0:00:0 | SW | No Violations | |
-1647113124 | 2017-7-18 0:00: | SW | No Violations | 2.50 |
-1737074668 | 2012-2-7 0:00:0 | SW | No Violations | |
-1864889163 | 2013-5-21 0:00: | SW | No Violations | 2.00 |
-1911588042 | 2019-4-30 0:00: | SW | No Violations | 3.00 |
-1925226689 | 2012-2-6 0:00:0 | SW | No Violations | |
-1951318730 | 2012-4-2 0:00:0 | SW | No Violations | 1.00 |
-1955091513 | 2003-10-30 0:00 | SW | No Violations | |
-2001282175 | 2006-11-3 0:00: | AM | No Violations | |
-2055295516 | 2019-8-29 0:00: | SW | No Violations | 3.00 |
-2106917601 | 2011-3-29 0:00: | SW | No Violations | |
-2144624732 | 2010-12-30 0:00 | SW | No Violations | 0.50 |
-2145609305 | 2017-7-18 0:00: | SW | No Violations | 0.50 |
-261958333 | 2004-1-15 0:00: | SW | No Violations | |
-458782963 | 2011-8-15 0:00: | SW | No Violations | |
-46791302 | 2011-8-4 0:00:0 | SW | No Violations | |
-541053483 | 2018-3-19 0:00: | SW | No Violations | 1.00 |
-580954109 | 2011-8-14 0:00: | SW | No Violations | |
-610948027 | 2010-6-30 0:00: | SW | No Violations | |
-638340359 | 2008-2-11 0:00: | SW | No Violations | |
-645636996 | 2006-7-12 0:00: | SW | No Violations | |
-715308582 | 2017-5-30 0:00: | SW | No Violations | 1.00 |
-716623815 | 2005-4-7 0:00:0 | SW | No Violations | |
-721454940 | 2015-2-4 0:00:0 | SW | No Violations | 1.00 |
-787822038 | 2016-10-12 0:00 | SW | No Violations | 2.50 |
-825746201 | 2006-11-13 0:00 | SW | No Violations | |
-931388286 | 2009-9-1 0:00:0 | SW | No Violations | |
0000PL2241 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0001269i57 | 2001-02-23 | Salt Water Injection Well | No Violations | Follow - up on NOV , In - Complaince , company has pulled tubing and packer and is running in a new packer . Tested and passed , test pressure was 790lbs and ended at 785 lbs . |
000UIC1616 | 1996-01-02 | Salt Water Injection Well | No Violations | 1501: 9-3-07 (E) QUARTERLY REPORTS |
001269i850 | 2002-03-06 | Salt Water Injection Well | Violations Noted | An inspection of the well revealed the dike around the storage tanks has oil in it, catails growing up through the liner, and the dikes are not large enough to hold the fluid stored in them. The first dike has 3-210 tanks all hooked together,size 25x30x1=134 bbl , second dike has 2-210 tanks not hooked together, size30x30x1= 160 bbls. NEED TO CLEAN OUT ALL OILY SOIL, AND OILY GRAVEL, REMOVE ALL CATAILS FROM DIKE, BUILD FIRST DIKE TO HOLD AT LEAST 400 BBL OF FLUID. SECOND DIKE TO HOLD AT LEAST 240 BBLS OF FLUID. PUT IN NEW LINERS IN DIKES. |
0043993374 | 2012-08-30 | Salt Water Injection Well | No Violations | No violations noted at the time of inspection. |
0046791302 | 2011-08-04 | Salt Water Injection Well | Violations Noted | Standard UIC SWIW inspection revealed equalization of the injection tubing pressure and the annulus pressure. I called Tom at Bancequity (1:54 pm) and told him of the problem and told him to stop injection and schedule a MIT test. Dike liner is ripped and needs replaced. Horizontal tank is seeping brine into dike. Repair or replace tank. |
005609i203 | 2001-05-31 | Salt Water Injection Well | No Violations | No violations at this time. |
005609i243 | 2001-07-12 | Salt Water Injection Well | No Violations | No violations. |
0083526846 | 2010-03-23 | Salt Water Injection Well | No Violations | An inspection revealed no violations at the SWD well and related storage tank location. The UIC section will be contacted regarding the Transfer Pump Facility located approximately 1/2 mile from storage tank location. This facility consists of (2) 210 bbl tanks with no dike or liner and a 1550 polyeurothane tank downslope from tanks. Tanks relating to Ploski wells are also located next to the 210 bbl tanks. Water from Ploski tanks drain into poly tank via 2 plastic. A 2 green collapsable line then drains water into 210 bbl tank for transport to injection facility. |
0118397305 | 2012-03-29 | Salt Water Injection Well | No Violations | Meet with Mike McPeak at the tank dike. Mike has repaired the 30 mil liner. Repairs look good. Took pictures. 2 inch annulus ball valve has a crack in it. Annulus pressure zero. Need to do mini test. |
0125515542 | 2009-12-11 | Salt Water Injection Well | No Violations | An inspection revealed no violations at this time. The lease road will need to be graded in the Spring. |
01269i1229 | 2002-07-23 | Salt Water Injection Well | No Violations | Pressures on well meet requirements at this time, company has done a good job replacing liner in dike area. |
0150443190 | 2011-08-13 | Salt Water Injection Well | No Violations | Pull tubing and packer. Parma co packer had trouble releasing then dragged up the hole. |
0154772706 | 2002-11-21 | Salt Water Injection Well | No Violations | No violations at this time, lease rd will need graded and water breaks in spring. |
0195514727 | 2011-08-12 | Administrative Inspection | No Violations | Received a call from Tom at Bancequity ( 8:15 am. ) Tom told me that they tested the annulus and it is equalizing. I reminded him to not inject until the problem is fixed and the annulus is tested. He will get their rig on site and notify me. Tom is planning on replacing the packer. |
0201733187 | 2012-02-29 | Salt Water Injection Well | No Violations | Accompanied Inspector Jon Scott on the inspection of the liner that was patched for the tank battery. Met with company man Mr. Mike McPeak. |
0207654493 | 2017-04-26 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
0227093055 | 2015-08-10 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Assisted UIC section Geologist in measuring the containment dike. Annulus initially had 180 psi the same as the injection tubing. I had the pumper bleed down the annulus pressure to 165 and observed the state issued gauge for 15 minutes with no change in annulus pressure while the injection pump was continuously running. |
0261958333 | 2004-01-15 | Salt Water Injection Well | No Violations | No violations. |
0343262004 | 2013-03-28 | Salt Water Injection Well | No Violations | Inspected the injection pressure and the annulus pressure along with the tank battery and the pump house. Updated GPS for well, access road and tanks. Liner repair tape has separated from the liner in multiple areas. I talked with Mike McPeak about the liner condition. Mike told me that they plan to fix the areas where the tape has pulled up and then to cover the liner to protect it from the Sun light. |
0363236297 | 2016-01-27 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted at the dike and well. Location is snow covered. |
0364953680 | 2015-10-15 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted at well and dike. Dike is free of fluids. |
0386603856 | 2013-04-05 | Salt Water Injection Well | No Violations | Accompanied Inspector Kip Thompson on inspection. Witnessed repairs being made to tank battery liner. Liner was being covered with soil after repairs were made. |
0458782963 | 2011-08-15 | Salt Water Injection Well | No Violations | Attempt to test annulus. Pumped to 490 psi then pressure drops off. Pressurized multiple times with the same results. Pulling tubing and test tubing on site. |
0541053483 | 2018-03-19 | Salt Water Injection Well | No Violations | My inspection revealed the salt water injection well had 110 psi on the injection tubing and had 210 psi on the annulus. The well had a legible identification. |
0549957259 | 2008-05-27 | Salt Water Injection Well | No Violations | No violations were noted. |
0558280744 | 2016-05-12 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure, and annulus pressure. Identification posted at the well and facility. The injection tubing pressure was 220 psi and the annulus pressure was 220 psi. I called Mike McPeak and He came to the well site. Mike opened the annulus and released the annulus pressure to 170 psi. all fluids were contained in a bucket. The annulus pressure was monitored for 15 minutes with no change from the 170 psi. The injection pump was operating during the monitoring of the annulus pressure. |
0580954109 | 2011-08-14 | Salt Water Injection Well | No Violations | Pulled packer completely out of hole. Installed new Parma Co packer. Run tubing and packer back in hole. |
0610948027 | 2010-06-30 | Salt Water Injection Well | No Violations | An inspection revealed no violations. Observed injection at time of the inspection. |
0638340359 | 2008-02-11 | Salt Water Injection Well | No Violations | No violations were noted. |
0645636996 | 2006-07-12 | Salt Water Injection Well | Violations Noted | An inspection was conducted at the facility owned by Bancequity Petroleum Corp. on 7/12/2006. During the inspection, it was noted that the ID located at the storage tanks did not contain the correct lease name. |
0690419385 | 2014-11-14 | Salt Water Injection Well | No Violations | UIC inspection, I checked the annulus pressure and the injection pressure. This test was done to determine the mechanical integrity of the this well that is being used for enhanced recovery. |
0715308582 | 2017-05-30 | Salt Water Injection Well | No Violations | Salt water injection well inspection. The injection pressure was 258 PSI, the annulus pressure was 247 PSI. No violations noted. |
0716623815 | 2005-04-07 | Salt Water Injection Well | Violations Noted | An inspection of the well revealed the 1/4 valve on the annular side does not work, several holes in side of storage tank, oil & brine soils in dike area around tanks. |
0721454940 | 2015-02-04 | Salt Water Injection Well | No Violations | Follow up inspection and mini test of the annulus. The electric was turned off to the Ploski ERP injection pump. The annulus was tested at 315 psi for 15 minutes with a loss of 5 psi. A leak on top of a two inch ball valve on the annulus was observed during the test. Test pressure after 15 minutes was 310 psi. Repairs are being made to the fitting on the Ploski injection pump. The pump was leaking brine on the outlet side of the pump at the 3/4 threaded connection between the hose and the pump. |
0780028923 | 2007-01-16 | Salt Water Injection Well | No Violations | No violations were noted. |
0787822038 | 2016-10-12 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted at the containment dike and well. The containment dike is free of fluids. |
0818775232 | 2003-01-30 | Salt Water Injection Well | No Violations | No violations at this time. |
0825746201 | 2006-11-13 | Salt Water Injection Well | No Violations | A follow-up inspection on 11/13/2006 revealed that the previously noted violations have been resolved. |
0931388286 | 2009-09-01 | Salt Water Injection Well | No Violations | An inspection was conducted with Mr. Jeff Fry, West Region Oil & Gas Supervisor and UIC Field Supervisor. During the inspection, it was noted that substantial erosion exists along bottom section of lease road. The back section closer to the well was found in good condition. |
0988157535 | 2011-12-13 | Salt Water Injection Well | No Violations | Tank leak has been repaired. Dike liner is being excavated for repair to the liner. Liner has not been repaired. Accompanied by Andy Thomas MRI. |
1085785738 | 2018-09-05 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted. The containment dike is free of fluids. |
1136427680 | 2009-03-02 | Salt Water Injection Well | No Violations | An inspection revealed that the injection line appears to contain a small leak around a fitting. Approximately 1 x 1 of fresh oil was observed on the ground surface, located between the pump and the well. The company was contacted by telephone regarding this inspection. |
1140001018 | 2016-08-09 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted at the well and facility. The containment dike is free of fluids. |
1150312556 | 2009-06-15 | Salt Water Injection Well | No Violations | An inspection revealed old oil from 2 steel line after pump house location measuring approximately 10 x 2. The Production Manager, Mr. Mike Cremean, had been contacted by telephone following the previous inspection and instructed to address the line. The line has been repaired. No violations at this time. |
1168987590 | 2013-09-06 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, annulus pressure, and injection pressure. Containment dikes are free of water. Good identification at the wellhead. |
1187529685 | 2007-04-20 | Salt Water Injection Well | No Violations | No violations were noted. |
1217982588 | 2008-09-16 | Salt Water Injection Well | No Violations | No violations were noted. |
125515542 | 2009-12-11 0:00 | SW | No Violations | |
1269i1229 | 2002-7-23 0:00: | SW | No Violations | |
1269i13505 | 2001-01-18 | Salt Water Injection Well | No Violations | An inspection of the injection and annulus pressures revealed that both pressures are the same and a M.I.T. test will need done on this well as soon as possible. Test must be witnessed by an inspection. |
1269i1350582 | 2001-1-18 0:00: | SW | No Violations | |
1269i57 | 2001-2-23 0:00: | SW | No Violations | |
1269i850 | 2002-3-6 0:00:0 | SW | No Violations | |
1273752688 | 2014-03-11 | Salt Water Injection Well | Violations Noted | Inspected both containment dikes, tanks, injection lines, injection pump, injection pressure, and annulus pressure. Upper containment dike with two horizontal tanks has multiple holes in the dike liner. Dike liner must be water tight 1501:9-3-05 (A)(6). Electric service line is four feet off the ground. Reattach electric line to power pole. The 2 injection line at the well site has a leak at ground level. A High Range Quantab was placed in the brine around the injection line. The Cl levels were over 6508 ppm. Brine scald areas, 2 feet in diameter and 4 feet by 12 feet down slope. Repair injection line and remove contaminated soil and haul to an EPA approved landfill. I called Mike McPeak and told him to shut down the injection operations until repairs to the injection line can be done 1501:9-3-07(I). Mike told me that he will be sending a crew over today to fix the leak. |
1285258297 | 2010-09-23 | Salt Water Injection Well | No Violations | An inspection revealed no violations. Note: The gauge utilized for this inspection will require calibration. |
1324988341 | 2011-12-13 | Salt Water Injection Well | No Violations | Accompanied Jon Scott on inspection. |
1330973286 | 2006-10-10 | Salt Water Injection Well | No Violations | An inspection conducted on 10/10/2006 revealed that identification is still needed at the storage tanks. Also noted was that a fitting is leaking on the annulus side of the well. The owner was informed on 10/10/2006 that the violations have not been resolved. |
1332168620 | 2017-05-23 | Salt Water Injection Well | No Violations | Bancequity on site using a 2 inch diameter water pump to wash down the mud in the holding pond that contained chlorides. The chloride content was approximately 600 PPM. They have turned the mud into a slurry and let the slurry settle. After the slurry has cleared up, it will be taken to a injection well. The remaining mud will be checked for chloride content after this procedure is complete. |
1365187205 | 2013-04-05 | Salt Water Injection Well | No Violations | Injection well inspection, I witnessed the repair of the liner. They were repairing the liner prior to covering the liner with soil. I was accompanied by Andy Thomas. The Latitude and longitude are recorded on the report Andy Thomas did. |
1369154493 | 2013-05-21 | Salt Water Injection Well | No Violations | I conducted a inspection to determine if the dike liner had been repaired and covered with soil. This has been done and vegetation has been established on the soil that was placed on the liner. |
1392961936 | 2014-03-11 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # -1273752688 Inspected both containment dikes, tanks, injection lines, injection pump, injection pressure, and annulus pressure. Upper containment dike with two horizontal tanks has multiple holes in the dike liner. Dike liner must be water tight 1501:9-3-05 (A)(6). Electric service line is four feet off the ground. Reattach electric line to power pole. The 2 injection line at the well site has a leak at ground level. A High Range Quantab was placed in the brine around the injection line. The Cl levels were over 6508 ppm. Brine scald areas, 2 feet in diameter and 4 feet by 12 feet down slope. Repair injection line and remove contaminated soil and haul to an EPA approved landfill. I called Mike McPeak and told him to shut down the injection operations until repairs to the injection line can be done 1501:9-3-07(I). Mike told me that he will be sending a crew over today to fix the leak. |
1395747926 | 2014-03-24 | Salt Water Injection Well | No Violations | Compliance Notice # 1273752688 Follow up inspection. Injection line leak has been repaired. A new 2 90 Ell and 2 nipple was installed. No leaks were observed during the inspection. The electric service line has been attached to the electric pole. Contaminated soil has been removed. Inspected the containment dikes, tanks, injection pump, injection line, injection pressure, and annulus pressure. Identification is posted at the tank dike and wellhead. |
1396050688 | 2008-12-22 | Salt Water Injection Well | No Violations | No violations were noted. Note: Winter conditions at time of the inspection. |
1410976293 | 2014-09-17 | Salt Water Injection Well | Violations Noted | Inspected the containment dikes, tanks, injection pump, injection line, annulus pressure, and injection pressure. A gravity feed production brine line is leaking at a valve manifold outside the containment dike. The scald area is 7 by 7. The water was tested with a high range Quantab. The Quantab was maxed out at 6508 ppm Cl. The annulus pressure was zero. I called and told Mike McPeak that they must fix the brine line leak and do a mini test on the annulus. Mike is mobilizing a crew to work on the leak today. Mini test is scheduled for 9-19-14. |
1411407904 | 2014-09-22 | Salt Water Injection Well | No Violations | Brine line leak has been repaired. Site has been remediated. Seed and mulch have been applied to location. A mini test was done by the company on the 9-18-14. I monitored my gage for 15 minutes with no loss during the inspection. Containment dike was free of water. Identification is posted at the containment dike and the well. |
1423141903 | 2015-02-04 | Salt Water Injection Well | Violations Noted | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Annulus had zero pressure. I contacted Mike McPeak and told them they need to do a mini test on the annulus today. The injection pump for the Ploski # 9 ERP injection well was leaking a steady spray of brine into the Beckley containment dike. The small amount of brine in the dike indicates that the leak is recent. There was a thin ice layer in the bottom of the containment dike approximately 90 %. |
1470931414 | 2012-10-24 | Salt Water Injection Well | No Violations | Both dikes are free of water. Injection pump not operating during inspection. Good identification at wellhead. |
1482441607 | 2016-12-22 | Salt Water Injection Well | No Violations | Mechanical Integrity Test. Tested the annulus at 780 psi, at 5 minutes 765 psi, at 15 minutes 745 psi. |
1495818529 | 2017-04-27 | Salt Water Injection Well | No Violations | I received a call from UIC inspector Jon Scott. Mr. Scott had located a area of brine kill. The kill area is below one of the 210 barrel tanks. I met with Mr. Mike McPeak. Mr. McPeak is the superintendent for the well owner Bancequity. We discussed a plan to remove the brine contaminated soil. One of the two 210 barrel tanks is in poor condition and will be replaced. When the tank is removed, the soil will be tested to determine the quantity of chlorides in the soil. After the contaminated soil is removed, a new 210 barrel tank will plumbed in to replace the tank that was removed. As of 4-27-2017, the 9 wells that fed this transfer facility are shut off and will remain shut off until the site has been remediated. |
1496148929 | 2017-05-30 | Production Wells | No Violations | I received a request from Mike McPeak to determine if there were any chlorides left in the containment area below the transfer station. I took three reading using quantabs. One reading at the source where there is water seeping out of a rock ledge. This reading was 2259 mg/L. The second spot was taken in the mud where the normal pool of water would be. This reading was 709 mg/L. The last test was in the remaining water in the pool and this reading was 2259 mg/L. I have notified Bancequity field manager Mike McPeak of my findings. |
1510360607 | 2004-03-10 | Salt Water Injection Well | No Violations | No violations at this time |
1513665948 | 2007-11-01 | Salt Water Injection Well | No Violations | No violations were noted. |
1531243947 | 2018-07-06 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pressure and annulus pressure. Identification is posted at the well and facility. The containment dike is free of fluids. |
1534435202 | 2005-06-29 | Salt Water Injection Well | No Violations | Follow-up on NOV, In-Compliance. |
1538833029 | 2018-06-28 | Salt Water Injection Well | No Violations | The access road to the well site is flooded and not accessible for inspection. |
1540566119 | 2018-10-25 | Salt Water Injection Well | No Violations | Inspected the containment dike, injection pump, injection line, injection pressure and annulus pressure. Identification posted, The containment dike is free of fluids. |
154772706 | 2002-11-21 0:00 | SW | No Violations | |
1551207588 | 2019-02-26 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure, and annulus pressure. Identification is posted. The containment dike has 6 inches of water in the low portion of the dike. |
1560835610 | 2012-02-07 | Salt Water Injection Well | No Violations | Accompanied Inspector Jon Scott on inspection of transfer pump station. Met with Mike McPeak from Bancequity and discussed ideas to put an unloading dock there, and upgrade the facility. |
1566300112 | 2016-11-16 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted. The containment dike is free of fluids. |
1582128167 | 2020-2-3 0:00:0 | SW | No Violations | 3.00 |
1596230794 | 2007-07-03 | Salt Water Injection Well | No Violations | No violations were noted. |
1605749644 | 2011-08-04 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # -46791302 Standard UIC SWIW inspection revealed equalization of the injection tubing pressure and the annulus pressure. I called Tom at Bancequity (1:54 pm) and told him of the problem and told him to stop injection and schedule a MIT test. Dike liner is ripped and needs replaced. Horizontal tank is seeping brine into dike. Repair or replace tank. |
1608968599 | 2012-06-14 | Salt Water Injection Well | No Violations | Pump was running at the time of inspection. A valve on one of the flow lines had a minute leak. Mr. Jess Hess was notified of this. |
1647113124 | 2017-07-18 | Salt Water Injection Well | No Violations | Compliance notice follow-up. The dike located below the 2-210 barrel tanks and the 2-100 barrel tanks has been cleaned up. I sampled the water in the dike using Quantab tritators and found approximately 200 PPM chlorides. This satisfies the compliance notice. |
1737074668 | 2012-02-07 | Salt Water Injection Well | No Violations | Met with Mike McPeak on site to discuss possibility of a unloading pad at the transfer pump facility. I told Mike that he will have to install a lined dike and a concrete unloading pad with a drain that is contained in a vault or tank. We discussed construction methods and the requirements that Tom Tomastik specified. |
1775878091 | 2011-08-31 | Salt Water Injection Well | No Violations | UIC. Witness Jess Hess run tubing and packer to 1814.78. |
1777940011 | 2011-08-04 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # -1605749644 FOLLOW UP TO NOV # -46791302 Standard UIC SWIW inspection revealed equalization of the injection tubing pressure and the annulus pressure. I called Tom at Bancequity (1:54 pm) and told him of the problem and told him to stop injection and schedule a MIT test. Dike liner is ripped and needs replaced. Horizontal tank is seeping brine into dike. Repair or replace tank. |
1824255906 | 2003-06-30 | Salt Water Injection Well | No Violations | No violations |
1853640929 | 2013-02-11 | Salt Water Injection Well | No Violations | An inspection revealed a minimal amount of water in the containment dike. There is also a splice that was made in the liner that needs re-taped. There are also small holes in the liner on the North facing side of the dike. Good identification was observered at the well head. Spoke with Mr. Mike McPeak about the liner issues and he stated he would get them taken care of when it warms up |
1859452999 | 2015-06-10 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Good identification posted at the containment dike and the well. |
1864889163 | 2013-05-21 | Salt Water Injection Well | No Violations | Inspected the injection pressure, annulus pressure, containment dikes and tanks. Dike wall has soil over the liner and grass is starting to establish on the top and sides of the dike. |
1869464102 | 2004-07-29 | Salt Water Injection Well | No Violations | No violations |
1925226689 | 2012-02-06 | Salt Water Injection Well | No Violations | Mike McPeak asked if I would look at this site for a possible brine unloading facility to be pumped to the injection well. The facility currently has a brine transfer pump that is used to move produced brine from production tanks to the brine storage tanks at the injection well site. Accompanied by Andy Thomas MRI. |
1951318730 | 2012-04-02 | Salt Water Injection Well | No Violations | Witnessed mini-test on the annulus. Pressure did not drop throughout the test. Test started at 9:33 am at 360 psi, and ended at 9:54 am at 360 psi. |
1955091513 | 2003-10-30 | Salt Water Injection Well | No Violations | No violations. |
195514727 | 2011-8-12 0:00: | AM | No Violations | |
1996942397 | 2019-10-4 0:00: | SW | No Violations | 1.00 |
2001282175 | 2006-11-03 | Administrative Inspection | No Violations | The company was contacted by telephone on 11/3/2006 and informed to resolve this violation within a week. |
201733187 | 2012-2-29 0:00: | SW | No Violations | 1.50 |
2031623827 | 2012-02-06 | Salt Water Injection Well | No Violations | Accompanied Inspector Jon Scott on the inspection of transfer pump station. |
2035751088 | 2011-09-01 | Salt Water Injection Well | No Violations | Set packer at 6000 lbs above string weight. Fill annulus with 23.5 bbls fresh water and 4 gallons corrosion inhibitor. Test at 830 psi for 15 minutes. At 15 minutes gauge read 825 psi. |
207654493 | 2017-4-26 0:00: | SW | No Violations | 3.00 |
2089652088 | 2014-07-02 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, injection pump, injection line, annulus pressure, and injection pressure. Identification posted on pole at the containment dike. The first containment dike with the two horizontal tanks has been disconnected and the tanks drained. This dike is to be rebuilt and relined. |
2093416908 | 2014-10-02 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Witnessed the line test from containment dike to the # 885 Ahmed Ellis surface facility and another line test from the containment dike to the # 779 Ploski #9 ERP. |
2106917601 | 2011-03-29 | Salt Water Injection Well | No Violations | Silver horizontal tank has hole in side and has leaked recently. Dike liner is ripped and needs to be repaired. I talked to Tom Fischieto and told him the liner needs repaired and the tank needs fixed. We also discussed the power line along access road is down on ground and needs to be attached to poles. |
2134140173 | 2017-12-14 | Salt Water Injection Well | No Violations | My inspection revealed the salt water injection well had 245 psi on the annulus and 160 psi on the injection tubing. The dike was free of fluids. Legible identification was posted. |
2144624732 | 2010-12-30 | Salt Water Injection Well | No Violations | An inspection revealed no violations at this time. |
2145609305 | 2017-07-18 | Salt Water Injection Well | No Violations | Quarterly UIC inspection. The annulus pressure was 180 PSI, the injection tubing was 158 PSI. Legible identification was posted. No violations noted. |
227093055 | 2015-8-10 0:00: | SW | No Violations | 1.00 |
343262004 | 2013-3-28 0:00: | SW | No Violations | 3.00 |
363236297 | 2016-1-27 0:00: | SW | No Violations | 2.50 |
364953680 | 2015-10-15 0:00 | SW | No Violations | 1.00 |
386603856 | 2013-4-5 0:00:0 | SW | No Violations | 0.50 |
43993374 | 2012-8-30 0:00: | SW | No Violations | 1.20 |
549957259 | 2008-5-27 0:00: | SW | No Violations | |
558280744 | 2016-5-12 0:00: | SW | No Violations | 2.00 |
5609i203 | 2001-5-31 0:00: | SW | No Violations | |
5609i243 | 2001-7-12 0:00: | SW | No Violations | |
690419385 | 2014-11-14 0:00 | SW | No Violations | 3.50 |
780028923 | 2007-1-16 0:00: | SW | No Violations | |
818775232 | 2003-1-30 0:00: | SW | No Violations | |
83526846 | 2010-3-23 0:00: | SW | No Violations | |
988157535 | 2011-12-13 0:00 | SW | No Violations | |
iTOMK00010 | 2001-01-18 | Salt Water Injection Well | Violations Noted | |
iTOMK000108 | 2001-1-18 0:00: | SW | No Violations | |
PL2241 | PL | No Violations | ||
UIC1616 | 1996-1-2 0:00:0 | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
001269i850 | US-OH-107481 | 2002-03-06 | Well operation causing pollution and contamination | |
001269i850 | US-OH-107482 | 2002-03-06 | No SPCC dike/or failure to keep dike free of water or oil | |
001269i850 | US-OH-107483 | 2002-03-06 | Contamination at surface facility (permit after 6-1-82) | |
0046791302 | US-OH-125073 | 2011-08-13 | Mechanical failure/contamination | |
0046791302 | US-OH-125074 | 2011-08-13 | Pits not liquid tight/Improper construction or use | |
0046791302 | US-OH-125075 | 2011-08-13 | Tanks not liquid tight/Improper burial | |
0645636996 | US-OH-127321 | 2006-07-24 | Failure to legibly identify well | |
0716623815 | US-OH-128140 | 2005-04-11 | Violation of injection tubing/fitting requirements | |
1273752688 | US-OH-107605 | 2014-04-10 | Pollution/Contamination | |
1410976293 | US-OH-112095 | 2014-09-25 | Pollution/Contamination | |
1410976293 | US-OH-112096 | 2014-09-25 | Failure to monitor annulus pressure | |
1423141903 | US-OH-112314 | 2016-07-26 | 9-3-07(F) | Failure to monitor annulus pressure |
iTOMK00010 | US-OH-131654 | Failure to perform Mechanical Integrity Test |