X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-163-20883

Well Details

Well ID: 34-163-20883
Loading map...
Country: United States
State: Ohio
County: Vinton
Municipality: Knox Township
Operator Name: BANCEQUITY PETROLEUM CORPORATI
Well Pad ID:
Farm/Lease Name: BECKLEY ETAL
License Status: Active Injection
License Date: 1986-03-20
Spud Date: 1986-01-15
Spud Drilling Contractor: R WOLFE DRLG
Final Drill Date: 1986-01-22
Well Total Depth: 2710.00 ft
Configuration: Vertical
Latitude: 39.220000
Longitude: -82.280000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1985-12-03 Issued Date 12/3/85 Expired Date 12/3/86 Acres 0020000 Tool Type RTA Proposed Formation BIG LIME Proposed Depth 02710 Proposed Drill Depth 02710
Original Spud 1986-01-15 CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86
Completed 1986-01-22 CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86
Reached Total Depth 1986-01-22 CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86
CO 1986-03-20 631 BT ENERGY CORP GeoDate 3/20/86
Conversion to Injector 1986-03-20
Salt Water Injection Well 1986-03-20 Issued Date 3/20/86 Expired Date 3/20/87 Acres 0020000 Tool Type RTA Proposed Formation ORISKANY Proposed Depth 02710 Proposed Drill Depth 02710
Storage Well 1986-03-20 Issued Date 3/20/86 Expired Date 3/20/87 Acres 0020000 Tool Type RTA Proposed Formation ORISKANY Proposed Depth 02710 Proposed Drill Depth 02710
First Injection 1986-05-11 CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86
CO 1986-08-17 2338 CHARTOR ENERGY CORP GeoDate 12/3/85
Construction Permit Expires 1987-03-20 CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86
Completion Report Received 1987-09-28 CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86
Annulus Pressure Monitoring Approved 1990-07-18 CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86
CO 1996-04-09 4801 BANCEQUITY PETROLEUM CORP GeoDate 3/20/86
Last Compliance Report 2011-09-23 CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86
Record Last Modified 2017-10-19 CONVERT 3-22-86, CHG. PTD/FORM/AC 1-18-86

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-09 2594 2606 2
2594 2606 2
2594 2606 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1000 Gal 0 FRAC: H2O,ACID CONVERT TO SWIW
H2O 0 130 Bbl 0 W/ADDITIVES.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1995 BANCEQUITY PETROLEUM CORPORATI 0.00 913.00 365
1997 BANCEQUITY PETROLEUM CORPORATI 721.00 135.00 365
2000 BANCEQUITY PETROLEUM CORPORATI 472.00 15.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1995 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
1997 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2000 BANCEQUITY PETROLEUM CORPORATI Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1085785738 2018-9-5 0:00:0 SW No Violations 2.20
-1136427680 2009-3-2 0:00:0 SW No Violations
-1140001018 2016-8-9 0:00:0 SW No Violations 2.00
-1168987590 2013-9-6 0:00:0 SW No Violations 1.00
-118397305 2012-3-29 0:00: SW No Violations
-1187529685 2007-4-20 0:00: SW No Violations
-1217982588 2008-9-16 0:00: SW No Violations
-1273752688 2014-3-11 0:00: SW No Violations 2.00
-1291330523 2020-6-1 0:00:0 SW No Violations 2.70
-1332168620 2017-5-23 0:00: SW No Violations 5.00
-1392961936 2014-3-11 0:00: SW No Violations 2.00
-1396050688 2008-12-22 0:00 SW No Violations
-150443190 2011-8-13 0:00: SW No Violations
-1596230794 2007-7-3 0:00:0 SW No Violations
-1605749644 2011-8-4 0:00:0 SW No Violations
-1647113124 2017-7-18 0:00: SW No Violations 2.50
-1737074668 2012-2-7 0:00:0 SW No Violations
-1864889163 2013-5-21 0:00: SW No Violations 2.00
-1911588042 2019-4-30 0:00: SW No Violations 3.00
-1925226689 2012-2-6 0:00:0 SW No Violations
-1951318730 2012-4-2 0:00:0 SW No Violations 1.00
-1955091513 2003-10-30 0:00 SW No Violations
-2001282175 2006-11-3 0:00: AM No Violations
-2055295516 2019-8-29 0:00: SW No Violations 3.00
-2106917601 2011-3-29 0:00: SW No Violations
-2144624732 2010-12-30 0:00 SW No Violations 0.50
-2145609305 2017-7-18 0:00: SW No Violations 0.50
-261958333 2004-1-15 0:00: SW No Violations
-458782963 2011-8-15 0:00: SW No Violations
-46791302 2011-8-4 0:00:0 SW No Violations
-541053483 2018-3-19 0:00: SW No Violations 1.00
-580954109 2011-8-14 0:00: SW No Violations
-610948027 2010-6-30 0:00: SW No Violations
-638340359 2008-2-11 0:00: SW No Violations
-645636996 2006-7-12 0:00: SW No Violations
-715308582 2017-5-30 0:00: SW No Violations 1.00
-716623815 2005-4-7 0:00:0 SW No Violations
-721454940 2015-2-4 0:00:0 SW No Violations 1.00
-787822038 2016-10-12 0:00 SW No Violations 2.50
-825746201 2006-11-13 0:00 SW No Violations
-931388286 2009-9-1 0:00:0 SW No Violations
0000PL2241 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0001269i57 2001-02-23 Salt Water Injection Well No Violations Follow - up on NOV , In - Complaince , company has pulled tubing and packer and is running in a new packer . Tested and passed , test pressure was 790lbs and ended at 785 lbs .
000UIC1616 1996-01-02 Salt Water Injection Well No Violations 1501: 9-3-07 (E) QUARTERLY REPORTS
001269i850 2002-03-06 Salt Water Injection Well Violations Noted An inspection of the well revealed the dike around the storage tanks has oil in it, catails growing up through the liner, and the dikes are not large enough to hold the fluid stored in them. The first dike has 3-210 tanks all hooked together,size 25x30x1=134 bbl , second dike has 2-210 tanks not hooked together, size30x30x1= 160 bbls. NEED TO CLEAN OUT ALL OILY SOIL, AND OILY GRAVEL, REMOVE ALL CATAILS FROM DIKE, BUILD FIRST DIKE TO HOLD AT LEAST 400 BBL OF FLUID. SECOND DIKE TO HOLD AT LEAST 240 BBLS OF FLUID. PUT IN NEW LINERS IN DIKES.
0043993374 2012-08-30 Salt Water Injection Well No Violations No violations noted at the time of inspection.
0046791302 2011-08-04 Salt Water Injection Well Violations Noted Standard UIC SWIW inspection revealed equalization of the injection tubing pressure and the annulus pressure. I called Tom at Bancequity (1:54 pm) and told him of the problem and told him to stop injection and schedule a MIT test. Dike liner is ripped and needs replaced. Horizontal tank is seeping brine into dike. Repair or replace tank.
005609i203 2001-05-31 Salt Water Injection Well No Violations No violations at this time.
005609i243 2001-07-12 Salt Water Injection Well No Violations No violations.
0083526846 2010-03-23 Salt Water Injection Well No Violations An inspection revealed no violations at the SWD well and related storage tank location. The UIC section will be contacted regarding the Transfer Pump Facility located approximately 1/2 mile from storage tank location. This facility consists of (2) 210 bbl tanks with no dike or liner and a 1550 polyeurothane tank downslope from tanks. Tanks relating to Ploski wells are also located next to the 210 bbl tanks. Water from Ploski tanks drain into poly tank via 2 plastic. A 2 green collapsable line then drains water into 210 bbl tank for transport to injection facility.
0118397305 2012-03-29 Salt Water Injection Well No Violations Meet with Mike McPeak at the tank dike. Mike has repaired the 30 mil liner. Repairs look good. Took pictures. 2 inch annulus ball valve has a crack in it. Annulus pressure zero. Need to do mini test.
0125515542 2009-12-11 Salt Water Injection Well No Violations An inspection revealed no violations at this time. The lease road will need to be graded in the Spring.
01269i1229 2002-07-23 Salt Water Injection Well No Violations Pressures on well meet requirements at this time, company has done a good job replacing liner in dike area.
0150443190 2011-08-13 Salt Water Injection Well No Violations Pull tubing and packer. Parma co packer had trouble releasing then dragged up the hole.
0154772706 2002-11-21 Salt Water Injection Well No Violations No violations at this time, lease rd will need graded and water breaks in spring.
0195514727 2011-08-12 Administrative Inspection No Violations Received a call from Tom at Bancequity ( 8:15 am. ) Tom told me that they tested the annulus and it is equalizing. I reminded him to not inject until the problem is fixed and the annulus is tested. He will get their rig on site and notify me. Tom is planning on replacing the packer.
0201733187 2012-02-29 Salt Water Injection Well No Violations Accompanied Inspector Jon Scott on the inspection of the liner that was patched for the tank battery. Met with company man Mr. Mike McPeak.
0207654493 2017-04-26 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
0227093055 2015-08-10 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Assisted UIC section Geologist in measuring the containment dike. Annulus initially had 180 psi the same as the injection tubing. I had the pumper bleed down the annulus pressure to 165 and observed the state issued gauge for 15 minutes with no change in annulus pressure while the injection pump was continuously running.
0261958333 2004-01-15 Salt Water Injection Well No Violations No violations.
0343262004 2013-03-28 Salt Water Injection Well No Violations Inspected the injection pressure and the annulus pressure along with the tank battery and the pump house. Updated GPS for well, access road and tanks. Liner repair tape has separated from the liner in multiple areas. I talked with Mike McPeak about the liner condition. Mike told me that they plan to fix the areas where the tape has pulled up and then to cover the liner to protect it from the Sun light.
0363236297 2016-01-27 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted at the dike and well. Location is snow covered.
0364953680 2015-10-15 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted at well and dike. Dike is free of fluids.
0386603856 2013-04-05 Salt Water Injection Well No Violations Accompanied Inspector Kip Thompson on inspection. Witnessed repairs being made to tank battery liner. Liner was being covered with soil after repairs were made.
0458782963 2011-08-15 Salt Water Injection Well No Violations Attempt to test annulus. Pumped to 490 psi then pressure drops off. Pressurized multiple times with the same results. Pulling tubing and test tubing on site.
0541053483 2018-03-19 Salt Water Injection Well No Violations My inspection revealed the salt water injection well had 110 psi on the injection tubing and had 210 psi on the annulus. The well had a legible identification.
0549957259 2008-05-27 Salt Water Injection Well No Violations No violations were noted.
0558280744 2016-05-12 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure, and annulus pressure. Identification posted at the well and facility. The injection tubing pressure was 220 psi and the annulus pressure was 220 psi. I called Mike McPeak and He came to the well site. Mike opened the annulus and released the annulus pressure to 170 psi. all fluids were contained in a bucket. The annulus pressure was monitored for 15 minutes with no change from the 170 psi. The injection pump was operating during the monitoring of the annulus pressure.
0580954109 2011-08-14 Salt Water Injection Well No Violations Pulled packer completely out of hole. Installed new Parma Co packer. Run tubing and packer back in hole.
0610948027 2010-06-30 Salt Water Injection Well No Violations An inspection revealed no violations. Observed injection at time of the inspection.
0638340359 2008-02-11 Salt Water Injection Well No Violations No violations were noted.
0645636996 2006-07-12 Salt Water Injection Well Violations Noted An inspection was conducted at the facility owned by Bancequity Petroleum Corp. on 7/12/2006. During the inspection, it was noted that the ID located at the storage tanks did not contain the correct lease name.
0690419385 2014-11-14 Salt Water Injection Well No Violations UIC inspection, I checked the annulus pressure and the injection pressure. This test was done to determine the mechanical integrity of the this well that is being used for enhanced recovery.
0715308582 2017-05-30 Salt Water Injection Well No Violations Salt water injection well inspection. The injection pressure was 258 PSI, the annulus pressure was 247 PSI. No violations noted.
0716623815 2005-04-07 Salt Water Injection Well Violations Noted An inspection of the well revealed the 1/4 valve on the annular side does not work, several holes in side of storage tank, oil & brine soils in dike area around tanks.
0721454940 2015-02-04 Salt Water Injection Well No Violations Follow up inspection and mini test of the annulus. The electric was turned off to the Ploski ERP injection pump. The annulus was tested at 315 psi for 15 minutes with a loss of 5 psi. A leak on top of a two inch ball valve on the annulus was observed during the test. Test pressure after 15 minutes was 310 psi. Repairs are being made to the fitting on the Ploski injection pump. The pump was leaking brine on the outlet side of the pump at the 3/4 threaded connection between the hose and the pump.
0780028923 2007-01-16 Salt Water Injection Well No Violations No violations were noted.
0787822038 2016-10-12 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted at the containment dike and well. The containment dike is free of fluids.
0818775232 2003-01-30 Salt Water Injection Well No Violations No violations at this time.
0825746201 2006-11-13 Salt Water Injection Well No Violations A follow-up inspection on 11/13/2006 revealed that the previously noted violations have been resolved.
0931388286 2009-09-01 Salt Water Injection Well No Violations An inspection was conducted with Mr. Jeff Fry, West Region Oil & Gas Supervisor and UIC Field Supervisor. During the inspection, it was noted that substantial erosion exists along bottom section of lease road. The back section closer to the well was found in good condition.
0988157535 2011-12-13 Salt Water Injection Well No Violations Tank leak has been repaired. Dike liner is being excavated for repair to the liner. Liner has not been repaired. Accompanied by Andy Thomas MRI.
1085785738 2018-09-05 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted. The containment dike is free of fluids.
1136427680 2009-03-02 Salt Water Injection Well No Violations An inspection revealed that the injection line appears to contain a small leak around a fitting. Approximately 1 x 1 of fresh oil was observed on the ground surface, located between the pump and the well. The company was contacted by telephone regarding this inspection.
1140001018 2016-08-09 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted at the well and facility. The containment dike is free of fluids.
1150312556 2009-06-15 Salt Water Injection Well No Violations An inspection revealed old oil from 2 steel line after pump house location measuring approximately 10 x 2. The Production Manager, Mr. Mike Cremean, had been contacted by telephone following the previous inspection and instructed to address the line. The line has been repaired. No violations at this time.
1168987590 2013-09-06 Salt Water Injection Well No Violations Inspected the containment dikes, tanks, annulus pressure, and injection pressure. Containment dikes are free of water. Good identification at the wellhead.
1187529685 2007-04-20 Salt Water Injection Well No Violations No violations were noted.
1217982588 2008-09-16 Salt Water Injection Well No Violations No violations were noted.
125515542 2009-12-11 0:00 SW No Violations
1269i1229 2002-7-23 0:00: SW No Violations
1269i13505 2001-01-18 Salt Water Injection Well No Violations An inspection of the injection and annulus pressures revealed that both pressures are the same and a M.I.T. test will need done on this well as soon as possible. Test must be witnessed by an inspection.
1269i1350582 2001-1-18 0:00: SW No Violations
1269i57 2001-2-23 0:00: SW No Violations
1269i850 2002-3-6 0:00:0 SW No Violations
1273752688 2014-03-11 Salt Water Injection Well Violations Noted Inspected both containment dikes, tanks, injection lines, injection pump, injection pressure, and annulus pressure. Upper containment dike with two horizontal tanks has multiple holes in the dike liner. Dike liner must be water tight 1501:9-3-05 (A)(6). Electric service line is four feet off the ground. Reattach electric line to power pole. The 2 injection line at the well site has a leak at ground level. A High Range Quantab was placed in the brine around the injection line. The Cl levels were over 6508 ppm. Brine scald areas, 2 feet in diameter and 4 feet by 12 feet down slope. Repair injection line and remove contaminated soil and haul to an EPA approved landfill. I called Mike McPeak and told him to shut down the injection operations until repairs to the injection line can be done 1501:9-3-07(I). Mike told me that he will be sending a crew over today to fix the leak.
1285258297 2010-09-23 Salt Water Injection Well No Violations An inspection revealed no violations. Note: The gauge utilized for this inspection will require calibration.
1324988341 2011-12-13 Salt Water Injection Well No Violations Accompanied Jon Scott on inspection.
1330973286 2006-10-10 Salt Water Injection Well No Violations An inspection conducted on 10/10/2006 revealed that identification is still needed at the storage tanks. Also noted was that a fitting is leaking on the annulus side of the well. The owner was informed on 10/10/2006 that the violations have not been resolved.
1332168620 2017-05-23 Salt Water Injection Well No Violations Bancequity on site using a 2 inch diameter water pump to wash down the mud in the holding pond that contained chlorides. The chloride content was approximately 600 PPM. They have turned the mud into a slurry and let the slurry settle. After the slurry has cleared up, it will be taken to a injection well. The remaining mud will be checked for chloride content after this procedure is complete.
1365187205 2013-04-05 Salt Water Injection Well No Violations Injection well inspection, I witnessed the repair of the liner. They were repairing the liner prior to covering the liner with soil. I was accompanied by Andy Thomas. The Latitude and longitude are recorded on the report Andy Thomas did.
1369154493 2013-05-21 Salt Water Injection Well No Violations I conducted a inspection to determine if the dike liner had been repaired and covered with soil. This has been done and vegetation has been established on the soil that was placed on the liner.
1392961936 2014-03-11 Salt Water Injection Well No Violations FOLLOW UP TO NOV # -1273752688 Inspected both containment dikes, tanks, injection lines, injection pump, injection pressure, and annulus pressure. Upper containment dike with two horizontal tanks has multiple holes in the dike liner. Dike liner must be water tight 1501:9-3-05 (A)(6). Electric service line is four feet off the ground. Reattach electric line to power pole. The 2 injection line at the well site has a leak at ground level. A High Range Quantab was placed in the brine around the injection line. The Cl levels were over 6508 ppm. Brine scald areas, 2 feet in diameter and 4 feet by 12 feet down slope. Repair injection line and remove contaminated soil and haul to an EPA approved landfill. I called Mike McPeak and told him to shut down the injection operations until repairs to the injection line can be done 1501:9-3-07(I). Mike told me that he will be sending a crew over today to fix the leak.
1395747926 2014-03-24 Salt Water Injection Well No Violations Compliance Notice # 1273752688 Follow up inspection. Injection line leak has been repaired. A new 2 90 Ell and 2 nipple was installed. No leaks were observed during the inspection. The electric service line has been attached to the electric pole. Contaminated soil has been removed. Inspected the containment dikes, tanks, injection pump, injection line, injection pressure, and annulus pressure. Identification is posted at the tank dike and wellhead.
1396050688 2008-12-22 Salt Water Injection Well No Violations No violations were noted. Note: Winter conditions at time of the inspection.
1410976293 2014-09-17 Salt Water Injection Well Violations Noted Inspected the containment dikes, tanks, injection pump, injection line, annulus pressure, and injection pressure. A gravity feed production brine line is leaking at a valve manifold outside the containment dike. The scald area is 7 by 7. The water was tested with a high range Quantab. The Quantab was maxed out at 6508 ppm Cl. The annulus pressure was zero. I called and told Mike McPeak that they must fix the brine line leak and do a mini test on the annulus. Mike is mobilizing a crew to work on the leak today. Mini test is scheduled for 9-19-14.
1411407904 2014-09-22 Salt Water Injection Well No Violations Brine line leak has been repaired. Site has been remediated. Seed and mulch have been applied to location. A mini test was done by the company on the 9-18-14. I monitored my gage for 15 minutes with no loss during the inspection. Containment dike was free of water. Identification is posted at the containment dike and the well.
1423141903 2015-02-04 Salt Water Injection Well Violations Noted Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Annulus had zero pressure. I contacted Mike McPeak and told them they need to do a mini test on the annulus today. The injection pump for the Ploski # 9 ERP injection well was leaking a steady spray of brine into the Beckley containment dike. The small amount of brine in the dike indicates that the leak is recent. There was a thin ice layer in the bottom of the containment dike approximately 90 %.
1470931414 2012-10-24 Salt Water Injection Well No Violations Both dikes are free of water. Injection pump not operating during inspection. Good identification at wellhead.
1482441607 2016-12-22 Salt Water Injection Well No Violations Mechanical Integrity Test. Tested the annulus at 780 psi, at 5 minutes 765 psi, at 15 minutes 745 psi.
1495818529 2017-04-27 Salt Water Injection Well No Violations I received a call from UIC inspector Jon Scott. Mr. Scott had located a area of brine kill. The kill area is below one of the 210 barrel tanks. I met with Mr. Mike McPeak. Mr. McPeak is the superintendent for the well owner Bancequity. We discussed a plan to remove the brine contaminated soil. One of the two 210 barrel tanks is in poor condition and will be replaced. When the tank is removed, the soil will be tested to determine the quantity of chlorides in the soil. After the contaminated soil is removed, a new 210 barrel tank will plumbed in to replace the tank that was removed. As of 4-27-2017, the 9 wells that fed this transfer facility are shut off and will remain shut off until the site has been remediated.
1496148929 2017-05-30 Production Wells No Violations I received a request from Mike McPeak to determine if there were any chlorides left in the containment area below the transfer station. I took three reading using quantabs. One reading at the source where there is water seeping out of a rock ledge. This reading was 2259 mg/L. The second spot was taken in the mud where the normal pool of water would be. This reading was 709 mg/L. The last test was in the remaining water in the pool and this reading was 2259 mg/L. I have notified Bancequity field manager Mike McPeak of my findings.
1510360607 2004-03-10 Salt Water Injection Well No Violations No violations at this time
1513665948 2007-11-01 Salt Water Injection Well No Violations No violations were noted.
1531243947 2018-07-06 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pressure and annulus pressure. Identification is posted at the well and facility. The containment dike is free of fluids.
1534435202 2005-06-29 Salt Water Injection Well No Violations Follow-up on NOV, In-Compliance.
1538833029 2018-06-28 Salt Water Injection Well No Violations The access road to the well site is flooded and not accessible for inspection.
1540566119 2018-10-25 Salt Water Injection Well No Violations Inspected the containment dike, injection pump, injection line, injection pressure and annulus pressure. Identification posted, The containment dike is free of fluids.
154772706 2002-11-21 0:00 SW No Violations
1551207588 2019-02-26 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure, and annulus pressure. Identification is posted. The containment dike has 6 inches of water in the low portion of the dike.
1560835610 2012-02-07 Salt Water Injection Well No Violations Accompanied Inspector Jon Scott on inspection of transfer pump station. Met with Mike McPeak from Bancequity and discussed ideas to put an unloading dock there, and upgrade the facility.
1566300112 2016-11-16 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted. The containment dike is free of fluids.
1582128167 2020-2-3 0:00:0 SW No Violations 3.00
1596230794 2007-07-03 Salt Water Injection Well No Violations No violations were noted.
1605749644 2011-08-04 Salt Water Injection Well No Violations FOLLOW UP TO NOV # -46791302 Standard UIC SWIW inspection revealed equalization of the injection tubing pressure and the annulus pressure. I called Tom at Bancequity (1:54 pm) and told him of the problem and told him to stop injection and schedule a MIT test. Dike liner is ripped and needs replaced. Horizontal tank is seeping brine into dike. Repair or replace tank.
1608968599 2012-06-14 Salt Water Injection Well No Violations Pump was running at the time of inspection. A valve on one of the flow lines had a minute leak. Mr. Jess Hess was notified of this.
1647113124 2017-07-18 Salt Water Injection Well No Violations Compliance notice follow-up. The dike located below the 2-210 barrel tanks and the 2-100 barrel tanks has been cleaned up. I sampled the water in the dike using Quantab tritators and found approximately 200 PPM chlorides. This satisfies the compliance notice.
1737074668 2012-02-07 Salt Water Injection Well No Violations Met with Mike McPeak on site to discuss possibility of a unloading pad at the transfer pump facility. I told Mike that he will have to install a lined dike and a concrete unloading pad with a drain that is contained in a vault or tank. We discussed construction methods and the requirements that Tom Tomastik specified.
1775878091 2011-08-31 Salt Water Injection Well No Violations UIC. Witness Jess Hess run tubing and packer to 1814.78.
1777940011 2011-08-04 Salt Water Injection Well No Violations FOLLOW UP TO NOV # -1605749644 FOLLOW UP TO NOV # -46791302 Standard UIC SWIW inspection revealed equalization of the injection tubing pressure and the annulus pressure. I called Tom at Bancequity (1:54 pm) and told him of the problem and told him to stop injection and schedule a MIT test. Dike liner is ripped and needs replaced. Horizontal tank is seeping brine into dike. Repair or replace tank.
1824255906 2003-06-30 Salt Water Injection Well No Violations No violations
1853640929 2013-02-11 Salt Water Injection Well No Violations An inspection revealed a minimal amount of water in the containment dike. There is also a splice that was made in the liner that needs re-taped. There are also small holes in the liner on the North facing side of the dike. Good identification was observered at the well head. Spoke with Mr. Mike McPeak about the liner issues and he stated he would get them taken care of when it warms up
1859452999 2015-06-10 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Good identification posted at the containment dike and the well.
1864889163 2013-05-21 Salt Water Injection Well No Violations Inspected the injection pressure, annulus pressure, containment dikes and tanks. Dike wall has soil over the liner and grass is starting to establish on the top and sides of the dike.
1869464102 2004-07-29 Salt Water Injection Well No Violations No violations
1925226689 2012-02-06 Salt Water Injection Well No Violations Mike McPeak asked if I would look at this site for a possible brine unloading facility to be pumped to the injection well. The facility currently has a brine transfer pump that is used to move produced brine from production tanks to the brine storage tanks at the injection well site. Accompanied by Andy Thomas MRI.
1951318730 2012-04-02 Salt Water Injection Well No Violations Witnessed mini-test on the annulus. Pressure did not drop throughout the test. Test started at 9:33 am at 360 psi, and ended at 9:54 am at 360 psi.
1955091513 2003-10-30 Salt Water Injection Well No Violations No violations.
195514727 2011-8-12 0:00: AM No Violations
1996942397 2019-10-4 0:00: SW No Violations 1.00
2001282175 2006-11-03 Administrative Inspection No Violations The company was contacted by telephone on 11/3/2006 and informed to resolve this violation within a week.
201733187 2012-2-29 0:00: SW No Violations 1.50
2031623827 2012-02-06 Salt Water Injection Well No Violations Accompanied Inspector Jon Scott on the inspection of transfer pump station.
2035751088 2011-09-01 Salt Water Injection Well No Violations Set packer at 6000 lbs above string weight. Fill annulus with 23.5 bbls fresh water and 4 gallons corrosion inhibitor. Test at 830 psi for 15 minutes. At 15 minutes gauge read 825 psi.
207654493 2017-4-26 0:00: SW No Violations 3.00
2089652088 2014-07-02 Salt Water Injection Well No Violations Inspected the containment dikes, tanks, injection pump, injection line, annulus pressure, and injection pressure. Identification posted on pole at the containment dike. The first containment dike with the two horizontal tanks has been disconnected and the tanks drained. This dike is to be rebuilt and relined.
2093416908 2014-10-02 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Witnessed the line test from containment dike to the # 885 Ahmed Ellis surface facility and another line test from the containment dike to the # 779 Ploski #9 ERP.
2106917601 2011-03-29 Salt Water Injection Well No Violations Silver horizontal tank has hole in side and has leaked recently. Dike liner is ripped and needs to be repaired. I talked to Tom Fischieto and told him the liner needs repaired and the tank needs fixed. We also discussed the power line along access road is down on ground and needs to be attached to poles.
2134140173 2017-12-14 Salt Water Injection Well No Violations My inspection revealed the salt water injection well had 245 psi on the annulus and 160 psi on the injection tubing. The dike was free of fluids. Legible identification was posted.
2144624732 2010-12-30 Salt Water Injection Well No Violations An inspection revealed no violations at this time.
2145609305 2017-07-18 Salt Water Injection Well No Violations Quarterly UIC inspection. The annulus pressure was 180 PSI, the injection tubing was 158 PSI. Legible identification was posted. No violations noted.
227093055 2015-8-10 0:00: SW No Violations 1.00
343262004 2013-3-28 0:00: SW No Violations 3.00
363236297 2016-1-27 0:00: SW No Violations 2.50
364953680 2015-10-15 0:00 SW No Violations 1.00
386603856 2013-4-5 0:00:0 SW No Violations 0.50
43993374 2012-8-30 0:00: SW No Violations 1.20
549957259 2008-5-27 0:00: SW No Violations
558280744 2016-5-12 0:00: SW No Violations 2.00
5609i203 2001-5-31 0:00: SW No Violations
5609i243 2001-7-12 0:00: SW No Violations
690419385 2014-11-14 0:00 SW No Violations 3.50
780028923 2007-1-16 0:00: SW No Violations
818775232 2003-1-30 0:00: SW No Violations
83526846 2010-3-23 0:00: SW No Violations
988157535 2011-12-13 0:00 SW No Violations
iTOMK00010 2001-01-18 Salt Water Injection Well Violations Noted
iTOMK000108 2001-1-18 0:00: SW No Violations
PL2241 PL No Violations
UIC1616 1996-1-2 0:00:0 SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
001269i850 US-OH-107481 2002-03-06 Well operation causing pollution and contamination
001269i850 US-OH-107482 2002-03-06 No SPCC dike/or failure to keep dike free of water or oil
001269i850 US-OH-107483 2002-03-06 Contamination at surface facility (permit after 6-1-82)
0046791302 US-OH-125073 2011-08-13 Mechanical failure/contamination
0046791302 US-OH-125074 2011-08-13 Pits not liquid tight/Improper construction or use
0046791302 US-OH-125075 2011-08-13 Tanks not liquid tight/Improper burial
0645636996 US-OH-127321 2006-07-24 Failure to legibly identify well
0716623815 US-OH-128140 2005-04-11 Violation of injection tubing/fitting requirements
1273752688 US-OH-107605 2014-04-10 Pollution/Contamination
1410976293 US-OH-112095 2014-09-25 Pollution/Contamination
1410976293 US-OH-112096 2014-09-25 Failure to monitor annulus pressure
1423141903 US-OH-112314 2016-07-26 9-3-07(F) Failure to monitor annulus pressure
iTOMK00010 US-OH-131654 Failure to perform Mechanical Integrity Test

For data sources see[9]

References