34-163-20950

Well Details

Well ID: 34-163-20950
Loading map...
Country: United States
State: Ohio
County: Vinton
Municipality: Madison Township
Operator Name: SLC ENERGY LTD
Well Pad ID:
Farm/Lease Name: MCGLAUGHLIN
License Status: Drilling
License Date: 2015-02-13
Spud Date: 2015-02-26
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 39.280000
Longitude: -82.380000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2015-02-13 Proposed Formations:BEREA, Issued Date:2/13/2015, Expired Date:2/12/2017 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:POOL
Construction Permit Expires 2017-02-12
Record Last Modified 2017-11-08

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1004532293 2018-11-1 0:00: PW No Violations 0.70
-1559388873 2017-11-8 0:00: PL No Violations 2.00
-1584097183 2018-3-8 0:00:0 PW No Violations 1.50
-161569947 2015-3-6 0:00:0 DD No Violations 5.00
-1656380008 2019-3-14 0:00: PW No Violations 0.30
-173050174 2015-3-7 0:00:0 DD No Violations 7.00
-33120625 2019-7-25 0:00: PW No Violations 0.30
-672156973 2015-2-27 0:00: DD No Violations 1.00
-704295078 2017-3-20 0:00: PW No Violations 1.00
-746181370 2015-3-2 0:00:0 DD No Violations 4.00
-898525866 2015-3-3 0:00:0 DD No Violations 4.00
-962832035 2015-2-25 0:00: DD No Violations 5.50
0161569947 2015-03-06 Drill / Deepen / Reopen No Violations Kilbarger rig number 8 has reached 360 feet. They will be drilling today after all of the equipment gets started. 12 of snow and -6 degrees. Surface casing should be ran by Saturday 3/7/15.
0173050174 2015-03-07 Drill / Deepen / Reopen No Violations Surface casing inspection. 497 of 9.62 surface pipe ran thru the Big Injun. Good cement returns.
0672156973 2015-02-27 Drill / Deepen / Reopen No Violations 13.25 conductor has been set to 113. The conductor was cemented to surface with good cement returns.
0704295078 2017-03-20 Production Wells No Violations Compliance notice follow-up. The well consists of a wellhead with tubing and rods. No other production equipment is associated with this well. The production equipment was confiscated by Kilbarger due to a civil dispute between Kilbarger and SLC Energy. No attempt has been made to bring the well into compliance.
0704425076 2015-06-23 Preliminary Restoration No Violations Preliminary restoration inspection. The site contains the equipment needed to produce the well. The grading has been done. All that remains to be done is the seeding. I have contacted SLC Energy owner Ron Coleman regarding the schedule to have the seeding done.
0746181370 2015-03-02 Drill / Deepen / Reopen No Violations Kilbarger rig 8 is preparing to begin drilling for the 9.62 surface casing. I instructed Kilbarger to route a ditch around the site using erosion control devices as the topography above the site will drain to the drilling pad. They are using silt fence and straw bales to manage the run off when the temperature warms above freezing.
0815251769 2015-02-27 Drill / Deepen / Reopen No Violations Kilbarger Drilling reached TD by 2300 hours. 103 of 13.38 conductor was ran with 4 centralizers. The casing was cemented back to surface on 3/1/15.
0846750103 2015-05-12 Production Wells No Violations The tank battery has been completed. The well is pumping flow back water from the stimulation job.
0898525866 2015-03-03 Drill / Deepen / Reopen No Violations Kilbarger rig 8 has tripped back out of the hole to replace the bit. They will be drilling until they reach total depth to set the 9.62 surface casing.
0918552090 2018-07-13 Production Wells No Violations My inspection revealed there has been no attempt to bring the well into compliance. The well consists of a wellhead with tubing and rods. All the production valves on the wellhead are turned off. The well lacks the production equipment needed to produce gas and oil. The well is in violation of 1509:12(B), well shall be plugged. I do not have a working phone number for Mr. Ron Coleman. I do not have a working phone number for well owner Mr. Ron Coleman.
0962832035 2015-02-25 Drill / Deepen / Reopen No Violations Kilbarger drilling has rigged up and spudded the well. They are using 13.25 conductor, and 9.62 surface casing in case there is a mine void.
1004532293 2018-11-01 Production Wells No Violations My inspection revealed the wells status remains unchanged from my last inspection on 7.13.2018. There has been no attempt from well owner SLC ENERGY to bring the well into compliance. The well is in violation of lack of production, no legible identification and lack of final restoration. The well consists of a wellhead with tubing and rods. No other production equipment is associated with this well.
1058050879 2016-01-14 Production Wells Violations Noted Preliminary restoration inspection. The well preliminary restoration has not been finished. No legible identification posted.
1101870370 2017-09-12 Production Wells No Violations My inspection today revealed the well is not in compliance. The well consists of a wellhead, surface casing, production casing, tubing and rods. There is no other production equipment associated with this well. No attempt has been made to bring the well into compliance. The valves are closed at the wellhead.
1143603904 2015-03-09 Drill / Deepen / Reopen No Violations The surface casing cement had fell to approx. 70. Formation cement on site, they grouted the surface to surface. The cement stayed at the surface.
1231361657 2018-07-10 Preliminary Restoration No Violations Preliminary Restoration has not been done and the well is incapable of producing, no production lines hooked to wellhead. The company has not complied with the Compliance Notices. Spoke with landowner Scott McGlaughlin and he is very upset that the well is not in production and the lease road and well site has not been restored.
1424867438 2015-02-24 Drill / Deepen / Reopen No Violations Kilbarger has the site prepared. They have moved the rig on site and have prepared to start drilling on 02/25/15.
1547053032 2019-01-09 Production Wells No Violations My inspection revealed this wells status remains unchanged. The well was last inspected on 7.13.18. The well is incapable of production. All of the production equipment had been removed by Kilbarger Drilling for lack of payment. The well is in violation of lack of preliminary restoration. I have no way to contact well owner SLC Energy concerning the violations associated with this well. I met with landowner Mr. Scott McGlaughlin during my inspection. We discussed the violations and what can be done to have the wells plugged.
1559388873 2017-11-08 Preliminary Restoration Violations Noted My inspection revealed the well to be idle and incapable of production. The well consists of a wellhead with tubing and rods. All of the vales on the wellhead are shut in. The well lacks the production equipment needed to produce oil or gas. The pumping unit, tanks, production lines and separator were confiscated by the owner of this production equipment. The lease road and pad have substantial erosion. The site needs to be terraced, seeded and mulched to prevent further erosion. SLC Energy has 30 days to perform this action. New photographs were taken during my inspection.
1584097183 2018-03-08 Production Wells No Violations My inspection revealed there has been no attempt to bring the well into compliance. The well consists of a wellhead with tubing and rods. All the production valves on the wellhead are turned off. The well lacks the production equipment needed to produce gas and oil. The well is in violation of 1509:12(B), well shall be plugged. New pictures were taken during my inspection.
1656380008 2019-03-14 Production Wells No Violations My inspection revealed the status of the well remains unchanged since my last inspection on 1.09.19. The owner of the well has made no attempt to bring this well into compliance. The was cited for 1509:12(B) well shall be plugged on 07.12.16.
1729424182 2018-11-06 Drill / Deepen / Reopen No Violations Accompanied by Eric Conrad at time of inspection, company has not complied with Compliance Notices.
1743607786 2015-04-22 Drill / Deepen / Reopen No Violations Producers services on performing well stimulation. The well broke down at 1250 PSI. No violations noted.
1885994104 2020-4-27 0:00: PW No Violations 1.50
2011959488 2015-03-13 Drill / Deepen / Reopen No Violations Kilbarger rig 8 has began running 4.5 production casing. Formation Cementing on site to cement the production casing. The production casing they used was used casing. The casing was tested by Buckeye. I requested the inspection paperwork from Buckeye. I will obtain the testing paperwork on Monday 3/16/15.
2080144668 2016-07-12 Production Wells Violations Noted
704425076 2015-6-23 0:00: PL No Violations 3.00
815251769 2015-2-27 0:00: DD No Violations 1.00
846750103 2015-5-12 0:00: PW No Violations 1.50
918552090 2018-7-13 0:00: PW No Violations 0.20

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1058050879 US-OH-101094 2016-01-25 Failure to legibly identify well
1058050879 US-OH-101095 2016-01-25 Failure to meet well and/or tank battery setbacks from a railroad or roads
1559388873 US-OH-115229 2017-12-28 NONE5 Failure to restore within six months
2080144668 US-OH-121222 2016-07-26 NONE Well shall be plugged

For data sources see[3]