If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-163-20951 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.24,"lon":-82.63,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Vinton | |
Municipality: Richland Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: JOHN SCOTT | |
License Status: Storage Well | |
License Date: 2017-08-21 | |
Spud Date: 2017-08-31 | |
Spud Drilling Contractor: H A D INC | |
Final Drill Date: 2017-09-26 | |
Well Total Depth: 2350.00 ft | |
Configuration: Directional | |
Latitude: 39.240000 | |
Longitude: -82.630000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2017-08-21 | Proposed Formations:CLINTON SANDSTONE, Issued Date:8/21/2017, Expired Date:8/21/2019 12:00:00 PM, Drilling unit acres:80, Proposed Well Type:SO, Proposed Well Class:POOL |
Reached Total Depth | 2017-09-26 | |
Completion Report Received | 2018-01-30 | |
Correction to Well | 2019-02-08 | UPDATE TARGET PER AS-DRILLED PLAT |
Record Last Modified | 2019-03-19 | |
Construction Permit Expires | 2019-08-21 |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1148354169 | 2017-9-20 0:00: | DD | No Violations | 5.50 |
-1217524319 | 2017-9-15 0:00: | DD | No Violations | 4.50 |
-1671021839 | 2017-9-7 0:00:0 | DD | No Violations | 2.00 |
-34748139 | 2017-9-26 0:00: | DD | No Violations | 5.00 |
-587646123 | 2020-10-28 0:00 | SO | No Violations | 0.50 |
-902819490 | 2017-9-19 0:00: | DD | No Violations | 2.00 |
-909881309 | 2018-9-5 0:00:0 | SO | No Violations | 0.30 |
0034748139 | 2017-09-26 | Drill / Deepen / Reopen | No Violations | HAD Drilling has reached 2350 feet at 9:00 AM. They will cement the production string back to surface today. I did not witness the cementing of the production casing. |
0902819490 | 2017-09-19 | Drill / Deepen / Reopen | No Violations | My inspection today revealed Had Drilling is currently drilling on fresh water based drilling mud prior to setting the surface casing. They have reached approximately 380 feet. Erosion control is in place and maintained. No violations were noted. |
0909881309 | 2018-09-05 | Storage Well | No Violations | My Columbia Gas storage well inspection revealed the well had a legible identification. The lease road was in stable condition without substantial erosion. |
1148354169 | 2017-09-20 | Drill / Deepen / Reopen | No Violations | Had Drilling set 552 feet of 11.75 inch diameter 42 pound surface casing. CJ Cementing was on site to cement the surface casing. I witnessed the 10 barrels of cement returns to the surface. |
1217524319 | 2017-09-15 | Drill / Deepen / Reopen | No Violations | My inspection today revealed a pre spud meeting with Trans Canada, Had Drilling, Kilbarger Drilling. The meeting was run by Trans Canada and covered health, safety, environmental and the drilling schedule. |
1504185322 | 2017-08-31 | Drill / Deepen / Reopen | No Violations | My inspection revealed HAD Drilling has rigged up and began drilling for conductor casing. The permit condition required the conductor to be cemented back to surface. Columbia Gas Drilling Supervisor Mr. Rick Connley asked if that permit condition could be waved due to the conductor casing would be driven in with no annular space. Upon relating this question to District Supervisor Mr. Eric Conrad it was decided that the conductor casing would not need to be cemented back to surface as there would be no annular space. |
1671021839 | 2017-09-07 | Drill / Deepen / Reopen | No Violations | My inspection today revealed the 16 inch diameter conductor casing has been set. The conductor casing was installed with no annular space and was not cemented. The drilling rig has not yet arrived. |
1676018070 | 2019-02-19 | Storage Well | No Violations | This Columbia gas storage well is hooked up to the storage well system. Legible identification was posted. |
For data sources see[3]