{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.23,"lon":-82.3,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Vinton | |
Municipality: Knox Township | |
Operator Name: GRIM PAUL A | |
Well Pad ID: | |
Farm/Lease Name: DOSS | |
License Status: Plugged and Abandoned | |
License Date: 2012-06-05 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: 1930-08-25 | |
Well Total Depth: 1167.00 ft | |
Configuration: Vertical | |
Latitude: 39.230000 | |
Longitude: -82.300000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Completed | 1930-08-25 | DTD=1166 1/2 |
Reached Total Depth | 1930-08-25 | DTD=1166 1/2 |
Change of Owner | 2001-11-21 | Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP. |
APP | 2012-06-05 | Proposed Formations:BEREA, Issued Date:6/5/2012, Expired Date:6/5/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2012-11-14 | DTD=1166 1/2 |
Record Last Modified | 2013-03-14 | DTD=1166 1/2 |
Construction Permit Expires | 2014-06-05 | DTD=1166 1/2 |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | GRIM PAUL A | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | GRIM PAUL A | Brine | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1037964085 | 2012-11-8 0:00: | PB | No Violations | 6.50 |
-1043078062 | 2013-7-16 0:00: | PW | No Violations | 1.00 |
-1360214859 | 2012-10-22 0:00 | PB | No Violations | 3.50 |
-1678547319 | 2012-10-10 0:00 | PB | No Violations | 3.00 |
-1900890852 | 2012-10-5 0:00: | PB | No Violations | 2.50 |
-423611402 | 2012-2-27 0:00: | AM | No Violations | 1.00 |
-594228125 | 2012-11-7 0:00: | PB | No Violations | 7.00 |
-916843438 | 2012-10-15 0:00 | PB | No Violations | 2.00 |
0064803174 | 2012-12-11 | Final Restoration | No Violations | Site has been graded and seed and straw have been applied over the disturbed areas. I am waiting on a landowner waiver for the flow line on this site. I have discussed this with Mr. Paul Thompson and the landowner Mr. Kenny Brooks. |
0213131386 | 2013-07-16 | Production Wells | No Violations | I accompanied Andrew Thomas on this inspection, the well has not been plugged and remains idle. |
0423611402 | 2012-02-27 | Administrative Inspection | No Violations | Spoke with Mr. Paul Thompson who works for Paul Grim in person about the Compliance Notice issued on this well. He stated that Mr. Grims plan was to plug the well, and they were getting paperwork in order to submit an application for that. |
0503285116 | 2012-11-13 | Plug / Plug Back | No Violations | Witnessed crew wash clay. When finished for the day, fluid level was 1 second down. |
0594228125 | 2012-11-07 | Plug / Plug Back | No Violations | Witnessed crew wash in 4 tons of clay. |
0747416231 | 2012-10-24 | Plug / Plug Back | No Violations | Crew was pulling 7 inch casing. |
0898447684 | 2012-10-03 | Plug / Plug Back | No Violations | Witnessed crew pulling tubing. Two joints were pulled and they found that the tubing was full of oil. I directed them to finish digging their pit and line it with plastic clear up to the well head before pulling any more tubing. I also flagged every piece of flow line that was scattered through the wood between the well site and US Route 50 where the tank sits. |
0916843438 | 2012-10-15 | Plug / Plug Back | No Violations | Checked on plugging rig. No activity. |
1037964085 | 2012-11-08 | Plug / Plug Back | No Violations | Witnessed crew wash 3 ton of clay in the wellbore. |
1043078062 | 2013-07-16 | Production Wells | No Violations | Status of well has not changed since last inspection. It is still idle. No attempt has been made to gain compliance. Accompanied by Inspector Kip Thompson. |
1301315238 | 2011-03-14 | Production Wells | Violations Noted | The only thing observed on the site was an old well head with rods and tubing. No pumpjack present. No tank battery observed. Well is idle. ORC 1509.062 Production was submitted for the year 2008 only and the numbers were all 0. No production was reported for 2009 or 2010. ORC 1509.11. Temporary inactive status should be filed for or well should be plugged unless it can be placed in production. Failure to comply may result in forfeiture of bond. |
1301757547 | 2012-10-11 | Plug / Plug Back | No Violations | Witnessed attempts to retrieve casing. Talked to property owner Kenny Brooks in person about final restoration procedures. |
1324397309 | 2011-12-20 | Production Wells | Violations Noted | The only thing observed on the site was an old well head with rods and tubing and miscellaneous pieces of steel pipe. No pumping unit present. No tank battery observed. No identification observed. Well is idle. Production was submitted for the year 2008 only and the numbers were all 0. No production was reported for 2009 or 2010. Temporary inactive status should be filed for or well should be plugged unless it can be placed in production. Failure to comply may result in forfeiture of bond. |
1350567681 | 2012-10-09 | Plug / Plug Back | No Violations | Witnessed plugging activities in progress. |
1351803121 | 2012-10-26 | Plug / Plug Back | No Violations | There was no activity at the site. There were 4 joints of 7 casing on the ground that had been pulled from the well. |
1352301677 | 2012-11-07 | Plug / Plug Back | No Violations | Crew had 43 joints of 7 pipe out of the hole. Spoke with Paul Thompson and he stated that there should only be 2 more joints left to pull and they should be washing clay by 12:00 or 1:00 pm. |
1352472321 | 2012-11-09 | Plug / Plug Back | No Violations | Checked on status of plugging rig. There was no activity at the time of inspection. I came back 2.5 hours later and the crew was there and ready to wash clay. They washed clay until they ran out of water. I received tickets for the clay during this visit. |
1360214859 | 2012-10-22 | Plug / Plug Back | No Violations | Witnessed company pulling 7 inch casing. Area around well had been excavated in order to hook on to the casing. Excavations were as much as 6 feet deep. |
1360842558 | 2012-11-14 | Plug / Plug Back | No Violations | Witnessed clay being washed to the surface. |
1678547319 | 2012-10-10 | Plug / Plug Back | No Violations | Witnessed plugging activities in progress. Crew attempted to pull 7 casing. |
1816689010 | 2011-03-14 | Production Wells | No Violations | FOLLOW UP TO NOV # 1301315238 The only thing observed on the site was an old well head with rods and tubing. No pumpjack present. No tank battery observed. Well is idle. ORC 1509.062 Production was submitted for the year 2008 only and the numbers were all 0. No production was reported for 2009 or 2010. ORC 1509.11. Temporary inactive status should be filed for or well should be plugged unless it can be placed in production. Failure to comply may result in forfeiture of bond. |
1900890852 | 2012-10-05 | Plug / Plug Back | No Violations | Arrived at site and made sure pit was lined. Clay was on site and covered with plastic. All tubing had been pulled. Received call from Paul Thompson stating that they were having problems with their water truck and they wouldnt be able to wash clay until next Tuesday. |
2009124728 | 2012-11-01 | Plug / Plug Back | No Violations | No activity at site. A gate was installed across the lease road. 13 joints of 7 casing have been pulled. |
213131386 | 2013-7-16 0:00: | PW | No Violations | 2.00 |
503285116 | 2012-11-13 0:00 | PB | No Violations | 4.00 |
64803174 | 2012-12-11 0:00 | FR | No Violations | 1.00 |
747416231 | 2012-10-24 0:00 | PB | No Violations | 2.00 |
898447684 | 2012-10-3 0:00: | PB | No Violations | 6.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1301315238 | US-OH-108500 | 2011-04-21 | Forfeiture of bond | |
1301315238 | US-OH-108501 | 2011-04-21 | Well shall be plugged | |
1301315238 | US-OH-108502 | 2011-03-28 | Nonproduction; well shall be plugged or placed in temporary inactive status | |
1301315238 | US-OH-108503 | 2011-03-28 | Statement of annual production not filed | |
1324397309 | US-OH-109279 | 2011-12-20 | Forfeiture of bond | |
1324397309 | US-OH-109280 | 2011-12-20 | Failure to legibly identify well | |
1324397309 | US-OH-109281 | 2011-12-20 | Well shall be plugged | |
1324397309 | US-OH-109282 | 2011-12-20 | Nonproduction; well shall be plugged or placed in temporary inactive status | |
1324397309 | US-OH-109283 | 2011-12-20 | Statement of annual production not filed |