If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-163-60495 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.23,"lon":-82.31,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Vinton | |
Municipality: Knox Township | |
Operator Name: GRIM PAUL A | |
Well Pad ID: | |
Farm/Lease Name: BROOKS N | |
License Status: Final Restoration | |
License Date: 1988-02-01 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: 1200.00 ft | |
Configuration: Vertical | |
Latitude: 39.230000 | |
Longitude: -82.310000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Plugged/Abandoned | 1988-03-01 | |
Construction Permit Expires | 1989-01-31 | |
Change of Owner | 2001-11-21 | Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP. |
Record Last Modified | 2013-03-14 |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1279759664 | 2013-7-16 0:00: | PW | No Violations | 1.50 |
-1547485092 | 2003-1-8 0:00:0 | FR | No Violations | |
-1909238839 | 2012-10-10 0:00 | PW | No Violations | 1.00 |
0374822451 | 2004-01-02 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 1961691473 An inspection revealed that the well has No ID at the well head, unable to locate tank battery. 1/12/04 to date company has not complied with NOV and corrected violations, turned over to management. |
0857308759 | 2004-02-11 | Production Wells | No Violations | Follow-up on NOV, Non-Compliance, company has not placed ID on well. |
1279759664 | 2013-07-16 | Production Wells | No Violations | Status of well has not changed since last inspection. It is still idle. No attempt has been made to gain compliance. Accompanied by Inspector Kip Thompson. Spoke with landowner on site. |
1350063088 | 2012-10-10 | Production Wells | Violations Noted | Well is listed as FR in the state database. There is a pumping unit attached to a well that is equipped for production. The pumping unit does not have a motor. There are lines attached to the well head and all valves are open. Due to oxidation on the polish rod, it is evident that the well has not been pumped in some time. There is no identification on the well. No tank battery was found for this well. No production records have been submitted. Well needs to be placed in production or plugged as per ORC 1509.062. Production records need submitted and complete identification needs to be posted on this well. |
1547485092 | 2003-01-08 | Final Restoration | No Violations | Final Rest. Meets 1509.072(B) requirements. |
1766236984 | 2013-07-16 | Production Wells | No Violations | I accompanied Andrew Thomas on this inspection, the well has not been plugged and remains idle. |
1909238839 | 2012-10-10 | Production Wells | No Violations | FOLLOW UP TO NOV # 1350063088 Well is listed as FR in the state database. There is a pumping unit attached to a well that is equipped for production. The pumping unit does not have a motor. There are lines attached to the well head and all valves are open. Due to oxidation on the polish rod, it is evident that the well has not been pumped in some time. There is no identification on the well. No tank battery was found for this well. No production records have been submitted. Well needs to be placed in production or plugged as per ORC 1509.062. Production records need submitted and complete identification needs to be posted on this well. |
1961691473 | 2004-01-02 | Production Wells | Violations Noted | An inspection revealed that the well has No ID at the well head, unable to locate tank battery. 1/12/04 to date company has not complied with NOV and corrected violations, turned over to management. |
374822451 | 2004-1-2 0:00:0 | PW | No Violations | |
857308759 | 2004-2-11 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0374822451 | US-OH-123952 | 2004-01-02 | Failure to legibly identify well | |
1350063088 | US-OH-110128 | 2012-10-31 | Failure to legibly identify well | |
1350063088 | US-OH-110129 | 2012-10-31 | Well shall be plugged | |
1350063088 | US-OH-110130 | 2012-10-31 | Nonproduction; well shall be plugged or placed in temporary inactive status | |
1350063088 | US-OH-110131 | 2012-10-31 | Statement of annual production not filed | |
1961691473 | US-OH-119799 | 2004-01-02 | Failure to legibly identify well |
For data sources see[3]