X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-163-60927

Well Details

Well ID: 34-163-60927
Loading map...
Country: United States
State: Ohio
County: Vinton
Municipality: Knox Township
Operator Name: HOCKING HILLS ENERGY AND WELL
Well Pad ID:
Farm/Lease Name: BROOKS HARVEY
License Status: Producing
License Date: 2015-03-12
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 39.230000
Longitude: -82.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2015-03-12 Proposed Formations:BEREA, Issued Date:3/12/2015, Expired Date:3/11/2017 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2017-02-10 RBDMS Rec
Construction Permit Expires 2017-03-11 RBDMS Rec

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2008 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2009 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2010 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2011 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2012 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2013 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2014 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 HOCKING HILLS ENERGY AND WELL Brine 0 0
2008 HOCKING HILLS ENERGY AND WELL Brine 0 0
2009 HOCKING HILLS ENERGY AND WELL Brine 0 0
2010 HOCKING HILLS ENERGY AND WELL Brine 0 0
2011 HOCKING HILLS ENERGY AND WELL Brine 0 0
2012 HOCKING HILLS ENERGY AND WELL Brine 0 0
2013 HOCKING HILLS ENERGY AND WELL Brine 0 0
2014 HOCKING HILLS ENERGY AND WELL Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1348402751 2015-2-5 0:00:0 PW No Violations 2.00
0470859609 2012-09-19 Production Wells No Violations No change since last inspection. Accompanied by company representative Bill Wray.
0944311644 2015-01-21 Administrative Inspection No Violations I met with Hocking Hills Energy partner Dave Poling. I gave Dave a list of outstanding compliance notices. I asked Dave to meet with his partners concerning the need to plug these wells. Dave told me he would contact me in two weeks with a schedule of work that needs accomplished on these wells.
1047704462 2015-01-21 Production Wells No Violations Compliance Follow-up 1463644798: The well is still incapable of production. The tubing is rusted through both sides and there are no production lines attached to the wellhead. There has been no resolution to any of the issues. I talked to Dave Poling with Hocking Hills Energy and explained the issues. He will work with the Vinton County Inspector, Kip Thompson, on a timeline to plug or produce the wells.
1195153206 2012-01-11 Production Wells No Violations FOLLOW UP TO NOV # 1463644798 Well is incapable of production. Rods and tubing present at the well head. Rod on top of the well head had been cut. Flow line from the well head had also been cut. Production records had stated zero production. Well will need to be placed in production or plugged. Photos were taken at inspection. Accompanied by Mr. Jon Scott. Spoke with Mr. Ron McBride about the well. He stated that the well will probably be plugged.
1250860561 2014-04-10 Production Wells No Violations This is a follow-up inspection for the well being idle. Andy Thomas and Kip Thompson inspected this well before and wrote it up for not the well not being able to produce. The violation was issued on 1/11/2012. The well is still idle and there has been no attempt to put the well back into production. I will contact Kip Thompson and let him know about the situation.
1297568115 2013-07-16 Production Wells No Violations I accompanied Andrew Thomas on this inspection, the well has not been plugged and remains idle.
1348402751 2015-02-05 Production Wells No Violations Compliance notice follow-up. I met with Hocking Hills Energy supervisor Doug Kitchen at the well site. The well consists of a wellhead with rods and tubing. I informed Doug of the need to plug the well.
1444306861 2015-10-07 Plug / Plug Back No Violations The well has 5 casing and conductor casing. Kilbarger pulled 4 joints of 5 casing and the cement plug was ran. The plug circulated after 10 barrels and I instructed Formation to stop as there was a hole in the 5 casing. 6 additional pipes were pulled and found the hole. It as decided to remove all of the 5 casing and run the tubing back in. The plugs were set without further problems.
1444323371 2015-10-08 Plug / Plug Back No Violations Hocking Hills Well Service topped of the surface plug. Formation cementing ran out of cement when the well was plugged on 10/7/15. The well was topped of with 3 yards of 9 sack grout.
1463644798 2012-01-11 Production Wells Violations Noted Well is incapable of production. Rods and tubing present at the well head. Rod on top of the well head had been cut. Flow line from the well head had also been cut. Production records had stated zero production. Well will need to be placed in production or plugged. Photos were taken at inspection. Accompanied by Mr. Jon Scott. Spoke with Mr. Ron McBride about the well. He stated that the well will probably be plugged.
1712844080 2012-01-11 Production Wells No Violations Accompanied Andy Thomas MRI on idle well inspection.
1809895019 2013-07-16 Production Wells No Violations Status of well has not changed since last inspection. It is still idle. No attempt has been made to gain compliance. Accompanied by Inspector Kip Thompson.
470859609 2012-9-19 0:00: PW No Violations 2.00
944311644 2015-1-21 0:00: AM No Violations 2.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1463644798 US-OH-113427 2012-01-18 Failure to legibly identify well
1463644798 US-OH-113428 2012-01-18 Well shall be plugged
1463644798 US-OH-113429 2012-01-18 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[7]

References