If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-163-60935 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.24,"lon":-82.63,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Vinton | |
Municipality: Richland Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: JOHN SCOTT | |
License Status: Plugged and Abandoned | |
License Date: 2017-06-05 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 39.240000 | |
Longitude: -82.630000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Well Added to System | 2017-06-02 | WELL WAS ADDED TO SYSTEM ON 6/2/2017 11:59:49 AM |
APP | 2017-06-05 | Proposed Formations:CLINTON SANDSTONE, Issued Date:6/5/2017, Expired Date:6/5/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SO, Proposed Well Class: |
Plugged/Abandoned | 2017-07-10 | |
Record Last Modified | 2018-06-05 | |
Construction Permit Expires | 2019-06-05 |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1254786199 | 2017-6-21 0:00: | PB | No Violations | 4.00 |
0154948244 | 2017-06-22 | Plug / Plug Back | No Violations | Columbia Gas drilling rig has reached 250 feet. They have removed mud from the wellbore. After reaching 700 feet, new 7 inch casing will be run and cemented to surface. This will give them a secure base for the blow out preventer. |
0707323980 | 2017-07-05 | Plug / Plug Back | No Violations | Columbia gas has reached 1695 feet. They are cleaning out the well so it can be plugged. They are using 6.25 inch diameter bit drilling on fluid. |
1254786199 | 2017-06-21 | Plug / Plug Back | No Violations | Columbia has a plugging rig on site. They have rigged up and began to clean out the 7 inch diameter casing. I noticed a leaking well approximately 2 miles from this well location. The well is leaking brine and gas. The kill area is 30 feet by 25 feet. The leaking well is approximately 400 feet from a Columbia Gas storage well. I was accompanied by Columbia Gas field superintendent Terry Vansickle. I tested the brine and maxed out high range quantabs. Mr. Vansickle indicated Columbia Gas would want to plug the well as it is in close proximity to one of there storage wells. I have also sent the information about the leaking well to idle orphan inspector Lynn Parkins. |
1497881209 | 2017-06-19 | Plug / Plug Back | No Violations | I received a call from Trans Canada field manager Terry Vansickle. Mr. Vansickle informed me they would have a service rig on site today to begin the plugging operations for this well. The rig was not on site. I called Mr. Vansickle and he stated the rig broke down and would be repaired and on site 6-21-2017. |
1498486998 | 2017-06-26 | Plug / Plug Back | No Violations | Columbia Gas service rig has tripped out the drilling pipe. New 7 inch diameter casing has been delivered and ran to approximately 680 feet. Petroset Cementing will be on site at 1400 hours to cement the pipe to surface. This will give Columbia Gas a secure platform to attach their blow out preventer. |
1499709028 | 2017-07-10 | Plug / Plug Back | No Violations | Cement training with Jimmy Wiles. Columbia Gas was plugging the well. I did not witness the plugging activity today. |
154948244 | 2017-6-22 0:00: | PB | No Violations | 8.00 |
707323980 | 2017-7-5 0:00:0 | PB | No Violations | 3.00 |
For data sources see[3]