If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-167-27477 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.46,"lon":-81.55,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Washington | |
Municipality: Watertown Township | |
Operator Name: POTTMEYER DUSTIN | |
Well Pad ID: | |
Farm/Lease Name: POTTMEYER R | |
License Status: Domestic Well | |
License Date: 1983-05-05 | |
Spud Date: 1983-06-14 | |
Spud Drilling Contractor: PUTNAM DRLG | |
Final Drill Date: 1983-06-20 | |
Well Total Depth: 2150.00 ft | |
Configuration: Vertical | |
Latitude: 39.460000 | |
Longitude: -81.550000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1983-05-05 | 225 CA-D'ORA INC GeoDate 5/5/83 |
Oil and Gas | 1983-05-05 | Issued Date 5/5/83 Expired Date 11/1/83 Acres 0020000 Tool Type RTF Proposed Formation BEREA Proposed Depth 02150 Proposed Drill Depth 02150 |
Original Spud | 1983-06-12 | |
Completed | 1983-06-20 | |
Reached Total Depth | 1983-06-20 | |
Construction Permit Expires | 1983-11-01 | |
Completion Report Received | 1984-08-10 | |
CO | 1996-09-24 | 3587 POTTMEYER ROBERT H GeoDate 5/5/83 |
Change of Owner | 2018-11-20 | Operator changed from 3587, POTTMEYER ROBERT H to 10234, POTTMEYER DUSTIN |
Record Last Modified | 2018-11-20 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 2060 | 2065 | 9 |
2060 | 2065 | 9 | |
2060 | 2065 | 9 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 50000 Gal | 50000 | FRAC;H2O,SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | COLUMBIA GAS TRANSMISSION LLC | 1385.00 | 163.00 | 0 |
1989 | POTTMEYER ROBERT H | 0.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | COLUMBIA GAS TRANSMISSION LLC | Brine | 3 | 0 |
1989 | POTTMEYER ROBERT H | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1426444840 | 2018-7-26 0:00: | PW | No Violations | 0.40 |
-76536051 | 2018-7-23 0:00: | PW | No Violations | 0.50 |
0000PL1857 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0076536051 | 2018-07-23 | Production Wells | Violations Noted | This is a domestic well. The well is equipped with a pumping unit, tubing, rods and an engine. There was a vertical separator and a steel 100-barrel tank. Identification was faded. I stopped at the house and asked them to post identification at the tank battery. They are also in the process of transferring the well as the owner is deceased. |
1199645387 | 2006-07-06 | Production Wells | No Violations | |
1409382932 | 2018-09-26 | Exempt Well Pre Transfer | No Violations | On this day, I am conducting a pre-exempt domestic transfer inspection. I found the well equipped with 4.5 inch diameter casing and 1.9 inch diameter tubing with the production valves open. It is setup to be produced by means of a pumping unit and appears capable of providing domestic gas. The production facility consists of (1) 100 barrel steel tank contained within and earthen dike. Additionally, there is a drip tank and vertical separator nearby. The production facility is not situated within the minimum 50 feet setback distance of the well, and poses no noticeable current environmental impact. Due to the age of the equipment, sliding and adjusting the spacing may create the potential for such an incident to occur. It has been in this location since the well was completed in 1984. I spoke with Southwest Supervisors Dan Goins and Eric Conrad for the approval to waive the requirement for tank spacing. |
1426444840 | 2018-07-26 | Production Wells | No Violations | The tank battery at the location is now properly identified. Violation is resolved. |
PL1857 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0076536051 | US-OH-128700 | 2018-08-06 | 9-9-05(A)10 | Failure to legibly identify well |
For data sources see[9]