Well Details

Well ID: 34-167-28621
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Wesley Township
Operator Name: BROAD STREET SERV LLC
Well Pad ID:
Farm/Lease Name: YEAGER
License Status: Final Restoration
License Date: 2011-11-22
Spud Date: 1988-12-24
Spud Drilling Contractor: MID ATLANTC DRLG
Final Drill Date: 1989-01-03
Well Total Depth: 5312.00 ft
Configuration: Vertical
Latitude: 39.420000
Longitude: -81.800000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1988-12-15 45 G W F CORPORATION GeoDate 12/15/88
Oil and Gas 1988-12-15 Issued Date 12/15/88 Expired Date 12/15/89 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05312 Proposed Drill Depth 05312
Original Spud 1988-12-24 CHANGED STATUS OF WELL FROM PA TO FR PER F_REST_PASS FACILITY REPORT FROM AUSTIN GUTRIDGE (SEE SURETY FILE) 9/29/2015 ON 10/1/2015 CM
Completed 1989-01-03 CHANGED STATUS OF WELL FROM PA TO FR PER F_REST_PASS FACILITY REPORT FROM AUSTIN GUTRIDGE (SEE SURETY FILE) 9/29/2015 ON 10/1/2015 CM
Reached Total Depth 1989-01-03 CHANGED STATUS OF WELL FROM PA TO FR PER F_REST_PASS FACILITY REPORT FROM AUSTIN GUTRIDGE (SEE SURETY FILE) 9/29/2015 ON 10/1/2015 CM
Completion Report Received 1989-10-06 CHANGED STATUS OF WELL FROM PA TO FR PER F_REST_PASS FACILITY REPORT FROM AUSTIN GUTRIDGE (SEE SURETY FILE) 9/29/2015 ON 10/1/2015 CM
CO 1995-08-31 3437 CEMCO OPERATING INC GeoDate 12/15/88
Change of Owner 2001-04-09 Operator changed from 3437, CEMCO OPERATING INC to 4350, CENTURY WELL SERVICE
Change of Owner 2007-10-03 Operator changed from 4350, CENTURY WELL SERVICE to 7033, BROAD STREET ENERGY COMPANY
Change of Owner 2008-02-19 Operator changed from 7033, BROAD STREET ENERGY COMPANY to 8312, BROAD STREET SERV LLC
APP 2011-11-22 Proposed Formations:CLINTON/MEDINA, Issued Date:11/22/2011, Expired Date:11/21/2013 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2013-10-23 CHANGED STATUS OF WELL FROM PA TO FR PER F_REST_PASS FACILITY REPORT FROM AUSTIN GUTRIDGE (SEE SURETY FILE) 9/29/2015 ON 10/1/2015 CM
Construction Permit Expires 2013-11-21 CHANGED STATUS OF WELL FROM PA TO FR PER F_REST_PASS FACILITY REPORT FROM AUSTIN GUTRIDGE (SEE SURETY FILE) 9/29/2015 ON 10/1/2015 CM
Record Last Modified 2015-10-01 CHANGED STATUS OF WELL FROM PA TO FR PER F_REST_PASS FACILITY REPORT FROM AUSTIN GUTRIDGE (SEE SURETY FILE) 9/29/2015 ON 10/1/2015 CM

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5031 5105 0
5031 5105 0
2006-09-11 5073 5077 5
5073 5077 5
5031 5105 0
2006-09-11 5085 5101 16
2006-09-11 5165 5173 9

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
GEL 0 65000 Gal 80000 FRAC:SAND/GEL WATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 CEMCO OPERATING INC 15871.00 0.00 255
1990 CEMCO OPERATING INC 4853.00 0.00 270
1992 CEMCO OPERATING INC 0.00 0.00 0
1994 CEMCO OPERATING INC 1950.00 0.00 365
1996 CEMCO OPERATING INC 0.00 0.00 0
1997 CEMCO OPERATING INC 0.00 0.00 365
1998 CEMCO OPERATING INC 0.00 0.00 365
1999 CENTURY WELL SERVICE 63.00 0.00 365
2000 CENTURY WELL SERVICE 0.00 0.00 365
2001 CEMCO OPERATING INC 56.00 0.00 365
2002 CENTURY WELL SERVICE 0.00 0.00 365
2003 CENTURY WELL SERVICE 0.00 0.00 365
2004 CENTURY WELL SERVICE 0.00 0.00 365
2005 CENTURY WELL SERVICE 0.00 0.00 365
2006 CENTURY WELL SERVICE 0.00 0.00 365
2007 BROAD STREET SERV LLC 56.00 0.00 365
2008 BROAD STREET SERV LLC 258.00 0.00 365
2009 BROAD STREET SERV LLC 434.00 0.00 365
2010 BROAD STREET SERV LLC 101.00 0.00 365
2011 BROAD STREET SERV LLC 0.00 0.00 0
2012 BROAD STREET SERV LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 CEMCO OPERATING INC Brine 560 255
1990 CEMCO OPERATING INC Brine 540 270
1992 CEMCO OPERATING INC Brine 0 0
1994 CEMCO OPERATING INC Brine 0 365
1996 CEMCO OPERATING INC Brine 0 0
1997 CEMCO OPERATING INC Brine 45 365
1998 CEMCO OPERATING INC Brine 0 365
1999 CENTURY WELL SERVICE Brine 0 365
2000 CENTURY WELL SERVICE Brine 0 365
2001 CEMCO OPERATING INC Brine 0 365
2002 CENTURY WELL SERVICE Brine 0 365
2003 CENTURY WELL SERVICE Brine 0 365
2004 CENTURY WELL SERVICE Brine 0 365
2005 CENTURY WELL SERVICE Brine 0 365
2006 CENTURY WELL SERVICE Brine 0 365
2007 BROAD STREET SERV LLC Brine 0 365
2008 BROAD STREET SERV LLC Brine 50 365
2009 BROAD STREET SERV LLC Brine 80 365
2010 BROAD STREET SERV LLC Brine 0 365
2011 BROAD STREET SERV LLC Brine 60 0
2012 BROAD STREET SERV LLC Brine 120 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1203266279 2013-10-22 0:00 AM No Violations 0.50
-1315370326 2013-10-25 0:00 PB No Violations 8.00
-1639818049 2013-10-15 0:00 PB No Violations 3.00
-1911991838 2011-9-6 0:00:0 PW No Violations 1.00
-1912504316 2013-10-17 0:00 AM No Violations
-676661496 2013-10-10 0:00 PB No Violations 2.00
-694666386 2004-12-27 0:00 PW No Violations
-711616392 2013-10-22 0:00 PB No Violations 3.00
0633202580 2013-10-15 Administrative Inspection No Violations I received a phone call from Mr. Ed Butler at 12:37 PM. He stated that they could not get the packer on this well to move to the bottom of the hole. They were at about 2700 ft. I told them that they needed to get to the bottom of the hole in order to set an adequate bottom hole plug. I suggested that the packer may have to be milled out.
0655834719 2015-09-29 Final Restoration No Violations Location has met 1509.072 B requirements.
0676661496 2013-10-10 Plug / Plug Back No Violations Crew was pulling tubing at the time of inspection. It was being difficult to pull. Spoke with Mr. Kenny OBrian from Broad Street and Donnie from Knox Energy. We discussed plugging procedure.
0694666386 2004-12-27 Production Wells No Violations Inspection this day found well shared with 8491, being metered together with current chart, not turning any production in for it but way up behind house and cant get to - may be house gas also, IDs good on 100 bbl tank, fair to good dike
0711616392 2013-10-22 Plug / Plug Back No Violations Witnessed the bottom hole plug being set. The bottom of the tubing was set at 4994 ft. A 30 sack plug was set at this depth.
1015455725 2013-10-24 Plug / Plug Back No Violations Showed up on site and no one was there. I called Mr. Donnie Strange and he stated that plugging will take place the next day.
1203266279 2013-10-22 Administrative Inspection No Violations Received phone call from Donnie from Knox Energy. He stated that they first tried to rip at 3800 ft, and the first telegraph they got was at 3000 ft. After consulting with Inspector Pat Shreve, I told them that they could rip there, pull the pipe, and run tubing back down to that depth and set a rip plug there to cover up the Big Lime.
1315370326 2013-10-25 Plug / Plug Back No Violations Witnessed the setting of the Lime plug, Berea plug, the bottom of surface plug and the surface plug. The Lime plug circulated. The others did not circulate fluid but pressure was observed on the backside during pumping. A bridge was set for the surface plug. Fluid level was 6.5 seconds down. Well was cemented from there to surface.
1315387920 2011-09-06 Production Wells Violations Noted Inspection this day due to complaint by landowner, Mr. Mike Whited. Says well has not produced in long time and black plastic line not buried, as required in lease, on his property. Found well standing idle, cedar tree growing up into it and could barely see well. Wellhead, casing rotted thru and sitting at angle - will need to be fixed to produce but found no odor - well not leaking. Valves shut - last annual production reported for 2010 but this is mistake - not possible well produced in 2010 and landowner verifies this. Says he has not received royalties since he moved in @2004. No IDs at well - required. Tanks have good IDs, chart in meter has no date, says it is for Yaeger #1, #2. Well needs put in production, IDs posted.
1334653183 2011-11-07 Production Wells No Violations Inspection this day found Broad Streets service rig set up on well. They are getting a water truck to dump water down tubing to see if well will circulate. It may have a hole in casing as the other Yaeger well does. Later in day the pump truck had to leaveand they did not get well pressure tested.
1639818049 2013-10-15 Plug / Plug Back No Violations It was reported to me that that there was a packer on the end of the tubing. It got caught on a hole in the casing and the tubing had to be shot off. During my visit the service rig crew was attempting to beat the packer down to the bottom of the well using the stem and jars. They were at a depth of 2100 ft.
1911991838 2011-09-06 Production Wells No Violations FOLLOW UP TO NOV # 1315387920 Inspection this day due to complaint by landowner, Mr. Mike Whited. Says well has not produced in long time and black plastic line not buried, as required in lease, on his property. Found well standing idle, cedar tree growing up into it and could barely see well. Wellhead, casing rotted thru and sitting at angle - will need to be fixed to produce but found no odor - well not leaking. Valves shut - last annual production reported for 2010 but this is mistake - not possible well produced in 2010 and landowner verifies this. Says he has not received royalties since he moved in @2004. No IDs at well - required. Tanks have good IDs, chart in meter has no date, says it is for Yaeger #1, #2. Well needs put in production, IDs posted.
1912504316 2013-10-17 Administrative Inspection No Violations Andy Thomas called and the Rig was beating on packer with jars to drive to bottom.
633202580 2013-10-15 0:00 AM No Violations 0.50
655834719 2015-9-29 0:00: FR No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1315387920 US-OH-108976 2011-09-07 Failure to legibly identify well
1315387920 US-OH-108977 2011-09-07 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[9]