X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-167-29245

Well Details

Well ID: 34-167-29245
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Wesley Township
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: JEFFERS
License Status: Producing
License Date: 1998-01-28
Spud Date: 1998-03-02
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1998-03-04
Well Total Depth: 1100.00 ft
Configuration: Vertical
Latitude: 39.420000
Longitude: -81.820000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1996-11-25 534 POWER RESOUR OPER CO INC GeoDate 11/25/96
Oil and Gas 1996-11-25 Issued Date 11/25/96 Expired Date 11/25/97 Acres 0010000 Tool Type RTA Proposed Formation SALT/MAXTON/KENR Proposed Depth Proposed Drill Depth
APP 1998-01-28 Proposed Formations:COW RUN/MAXTON/KEENER/BEREA, Issued Date:1/28/98, Expired Date:1/28/99 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:EOUT
Change of Owner 1998-01-28 Operator changed from 534, POWER RESOUR OPER CO INC to 4350, CENTURY WELL SERVICE. THIS WELL WAS NEVER DRILLED. PERMIT EXPIRED.
Original Spud 1998-03-02 RBDMS Rec
Completed 1998-03-04 RBDMS Rec
Reached Total Depth 1998-03-04 RBDMS Rec
Completion Report Received 1998-08-03 RBDMS Rec
Change of Owner 1998-10-14 Operator changed from 4350, CENTURY WELL SERVICE to 2348, TRIAD RESOURCES INC
Construction Permit Expires 1999-01-28 RBDMS Rec
Change of Owner 2000-04-26 Operator changed from 2348, TRIAD RESOURCES INC to 4350, CENTURY WELL SERVICE
Change of Owner 2006-03-20 Operator changed from 4350, CENTURY WELL SERVICE to 516, MURPHY OIL CO
Change of Owner 2017-04-14 Operator changed from 516, MURPHY OIL COMPANY INC to 9651, AM-TEK OIL INC
Record Last Modified 2017-04-14 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1998-10-16 1045 1051 13
1045 1051 13
1045 1051 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 700 Gal 0 ALSO USED 500 GALLONS ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2000 CENTURY WELL SERVICE 114.00 0.00 365
2001 CENTURY WELL SERVICE 994.00 0.00 365
2002 CENTURY WELL SERVICE 609.00 0.00 365
2003 CENTURY WELL SERVICE 0.00 0.00 365
2004 CENTURY WELL SERVICE 0.00 0.00 365
2005 CENTURY WELL SERVICE 0.00 0.00 365
2006 MURPHY OIL COMPANY INC 90.00 0.00 150
2007 MURPHY OIL COMPANY INC 260.00 0.00 365
2008 MURPHY OIL COMPANY INC 183.00 0.00 365
2009 MURPHY OIL COMPANY INC 244.00 0.00 365
2010 MURPHY OIL COMPANY INC 94.00 0.00 365
2011 MURPHY OIL COMPANY INC 2.00 0.00 60
2012 MURPHY OIL COMPANY INC 3.00 0.00 366
2013 MURPHY OIL COMPANY INC 15.00 0.00 90
2014 MURPHY OIL COMPANY INC 0.00 0.00 0
2015 MURPHY OIL COMPANY INC 0.00 0.00 0
2016 MURPHY OIL COMPANY INC 0.00 0.00 0
2017 MURPHY OIL COMPANY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2000 CENTURY WELL SERVICE Brine 115 365
2001 CENTURY WELL SERVICE Brine 0 365
2002 CENTURY WELL SERVICE Brine 225 365
2003 CENTURY WELL SERVICE Brine 150 365
2004 CENTURY WELL SERVICE Brine 150 365
2005 CENTURY WELL SERVICE Brine 0 365
2006 MURPHY OIL COMPANY INC Brine 0 150
2007 BROAD STREET SERV LLC Brine 0 365
2008 MURPHY OIL COMPANY INC Brine 0 365
2009 MURPHY OIL COMPANY INC Brine 0 365
2010 MURPHY OIL COMPANY INC Brine 0 365
2011 MURPHY OIL COMPANY INC Brine 0 60
2012 MURPHY OIL COMPANY INC Brine 0 366
2013 MURPHY OIL COMPANY INC Brine 0 90
2014 MURPHY OIL COMPANY INC Brine 0 0
2015 MURPHY OIL COMPANY INC Brine 0 0
2016 MURPHY OIL COMPANY INC Brine 0 0
2017 AM-TEK OIL INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-21882061 2006-9-19 0:00: PL No Violations
0021882061 2006-09-19 Preliminary Restoration No Violations Inspection this day found well with jack sitting nearby - will be set soon. Location has been reclaimed - looks good.
0895849157 2015-12-16 Production Wells No Violations Upon inspection, it was observed that brine contamination that was present on 4/6/2015 has been remediated. The well has yet to be put back into production.
1214296571 2011-11-17 Production Wells No Violations Don Morris is mineral owner and requested an inspection of this well. My inspection found this well is equipped with a pumping unit but the motor has been removed. The well valves are open. There is no well identification posted and the tank battery dike is in need of repair. The chart in the gas meter is dated 8/1/11.
1393060053 2015-04-06 Production Wells No Violations Performed an inspection on this well in response to a request from the landowner, Mr. Donald Morris. Upon inspection, it was observed that this well is capable of production, but is currently not producing. The well consists of a pumping unit standing over 4.5 casing and 1.5 tubing. The casing and tubing valves are open, but the pressure actuated gate valve is disconnected and cannot function. The well has not pumped in a long time judging by oxidation present on the polish rod. The tank battery consists of a 100 bbl production tank, mechanical separator, drip, and meter run. The chart in the meter is from 7-31-2014 and shows no production. There is an old brine kill area originating at a breach in the dike wall and extending 40 downhill from the dike. I spoke over the phone with Mr. John Murphy about this well and instructed him to get a crew out to clean up the contaminated area and he agreed. Mr. Murphy stated that he plans on servicing this well in addition to several other wells in the area this year.
895849157 2015-12-16 0:00 PW No Violations 0.50

For data sources see[9]

References