X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-167-29330

Well Details

Well ID: 34-167-29330
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Wesley Township
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: GREATHOUSE
License Status: Producing
License Date: 2002-03-05
Spud Date: 1998-02-23
Spud Drilling Contractor: CENTURY WELL SERVICES,INC
Final Drill Date: 1998-02-26
Well Total Depth: 1050.00 ft
Configuration: Vertical
Latitude: 39.420000
Longitude: -81.830000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1997-12-12 Proposed Formations:COW RUN/MAXTON/KEENER/BEREA, Issued Date:12/12/97, Expired Date:12/12/98 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 1998-02-23 RBDMS Rec
Completed 1998-02-26 RBDMS Rec
Reached Total Depth 1998-02-26 RBDMS Rec
Completion Report Received 1998-09-10 RBDMS Rec
Change of Owner 1998-10-14 Operator changed from 4350, CENTURY WELL SERVICE to 2348, TRIAD RESOURCES INC
Change of Owner 2000-04-26 Operator changed from 2348, TRIAD RESOURCES INC to 4350, CENTURY WELL SERVICE
APP 2002-03-05 Proposed Formations:MAXTON, Issued Date:3/5/2002, Expired Date:3/5/2003 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2003-03-05 RBDMS Rec
Change of Owner 2006-03-20 Operator changed from 4350, CENTURY WELL SERVICE to 516, MURPHY OIL CO
Change of Owner 2017-04-14 Operator changed from 516, MURPHY OIL COMPANY INC to 9651, AM-TEK OIL INC
Record Last Modified 2017-04-14 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1998-11-16 890 896 13
890 896 13
890 896 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 700 Gal 0 500 GALLONS IC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 MURPHY OIL COMPANY INC 6.00 0.00 10
2007 MURPHY OIL COMPANY INC 90.00 0.00 365
2008 MURPHY OIL COMPANY INC 220.00 0.00 365
2009 MURPHY OIL COMPANY INC 12.00 0.00 365
2010 MURPHY OIL COMPANY INC 13.00 0.00 365
2011 MURPHY OIL COMPANY INC 10.00 0.00 365
2012 MURPHY OIL COMPANY INC 30.00 0.00 0
2013 MURPHY OIL COMPANY INC 0.00 0.00 0
2014 MURPHY OIL COMPANY INC 77.00 0.00 0
2015 MURPHY OIL COMPANY INC 100.00 0.00 0
2016 MURPHY OIL COMPANY INC 0.00 0.00 0
2017 MURPHY OIL COMPANY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 MURPHY OIL COMPANY INC Brine 0 10
2007 MURPHY OIL COMPANY INC Brine 0 365
2008 MURPHY OIL COMPANY INC Brine 0 365
2009 MURPHY OIL COMPANY INC Brine 0 365
2010 MURPHY OIL COMPANY INC Brine 0 365
2011 MURPHY OIL COMPANY INC Brine 0 365
2012 MURPHY OIL COMPANY INC Brine 0 0
2013 MURPHY OIL COMPANY INC Brine 0 0
2014 MURPHY OIL COMPANY INC Brine 0 0
2015 MURPHY OIL COMPANY INC Brine 0 0
2016 MURPHY OIL COMPANY INC Brine 0 0
2017 AM-TEK OIL INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1322264128 2020-3-16 0:00: PW No Violations 0.50
-189532689 2019-4-2 0:00:0 PW No Violations 0.60
-2054242360 2015-12-16 0:00 PW No Violations 1.00
-29894549 2014-11-19 0:00 PW No Violations 1.00
-834702929 2012-1-9 0:00:0 PW No Violations 0.70
0029894549 2014-11-19 Production Wells No Violations Upon inspection, it was observed that this shut in and is idle. The well consists of 4.5 casing and 2 production tubing leading to 2 ball valves and associated 2 fittings. No production equipment was found to be associated with this well. No identification information is posted at the well head. I will contact Mr. John Murphy of Murphy Oil Co. Inc. and inquire about plans to plug and abandon this well.
0080364059 2015-10-20 Production Wells No Violations Upon inspection, it was observed that this well is not yet in production. There is now a meter run and associated steel lines on location which will be used to meter production once the well is put back in line. I will contact Mr. Kim Walker of Murphy Oil Co. and inquire about the status of the well.
0189532689 2019-04-02 Production Wells Violations Noted On this day, I am conducting an inspection per request of landowner Lawrence Woodruff in response to Complaint #6113. I found the well equipped with 4.5 inch diameter casing with a 4x2 inch diameter reduction swage, and the 2 inch production valve closed. It is setup to be produced as an open-flow well. There is an orifice sales meter nearby that is disconnected from the well. It will be noted that a 2 inch diameter steel flowline is connected to the wellhead, and appears to travel away from the well to an unknown destination. No identification is present at the wellhead, and the production records are current. Multiple pictures were taken. According to 1501:9-9-05(A)10, legible identification shall be posted in a conspicuous place on or near the wellhead or the storage tank(s) as to owner, lease name, well number, permit number, county, and an emergency contact number. If multiple wells are being produced into the common tank(s) each wellhead shall be identified as previously stated. An attempt to contact Andrew at AM-Tek Oil was made, and a voicemail was left stating that a compliance notice was being issued.
0580088084 2015-06-29 Administrative Inspection No Violations Met with John Murphy and Kim Walker of Murphy Oil, Tony Robinson of Robinson Contracting, and Richard Johnson of Logan Energy in Bartlett, OH to discuss this well. Mr. Walker, the well tender for this well, stated that the well is hooked up and will produce, but is shut in at the master meter by Columbia Gas. Mr. Murphy is trying to work out a deal with Old South Oil Co. to produce into their sales line nearby. I gave Mr. Murphy until mid-July to make a final decision on the well.
0600900549 2006-11-20 Preliminary Restoration No Violations Has just had rig on location and is very muddy, well producing thru casing, no tank but meter with current chart out at road, needs IDs up, has just got well going from buying from Century. Location HAD been reclaimed, will be smoothed out again.
0834702929 2012-01-09 Production Wells Violations Noted My inspection this day was due to a water well contamination complaint by landowner, Keith Snider. This is a casing well with the valves shut. There was no identification (ID) sign posted and no gas meter found. Our records show this well produced in 2010. This well needs to be put in production, plugged or put into Temporary Inactive status. Proper ID signs must also be posted.
1054107673 2015-08-18 Production Wells No Violations Upon inspection, it was observed that this location and lease road have been cleared and the well is now easily accessible. The well is still shut in. I spoke with Murphy Oil/Logan Energy Well Tender John Hesser and he stated that this well is scheduled to be worked on tomorrow to determine whether or not this well will produce. If the well does not produce, it will be plugged.
1197404396 2012-01-09 Production Wells No Violations FOLLOW UP TO NOV # -834702929 My inspection this day was due to a water well contamination complaint by landowner, Keith Snider. This is a casing well with the valves shut. There was no identification (ID) sign posted and no gas meter found. Our records show this well produced in 2010. This well needs to be put in production, plugged or put into Temporary Inactive status. Proper ID signs must also be posted.
1356649677 2019-05-14 Production Wells No Violations On this day, I am conducting a compliance notice follow-up inspection in regard to Complaint #6113. No progress has been made to gain compliance. No identification has been posted at the wellhead. The production valve is currently closed.
1427735382 2015-03-27 Production Wells No Violations Upon inspection, it was observed that no attempt has been made to gain compliance at this well location since the last inspection on 11/19/2014. The well is still shut in and is idle. I will speak with Mr. John Murphy and advise that he file for a plugging permit for this well and properly plug/abandon the well.
1571751536 2019-10-22 0:00 PW No Violations 1.90
1580749183 2020-1-30 0:00: PW No Violations 0.40
1833133525 2015-06-17 Production Wells No Violations Upon inspection, it was observed that no changes have been made to the location since the last inspection on 3/27/2015. The well is idle, but is capable of production. I will contact Mr. John Murphy of Murphy Oil Co. and request a meeting on location to discuss options to either service and produce or plug and abandon this well.
2054242360 2015-12-16 Production Wells No Violations Upon inspection, it was observed that no effort has been made to bring this well into compliance. The well is still idle. I will contact Mr. John Murphy and tell him to have the well producing by March or plug and abandon it. The failure to plug or produce the well will result in enforcement action by the division.
580088084 2015-6-29 0:00: AM No Violations 0.50
600900549 2006-11-20 0:00 PL No Violations
80364059 2015-10-20 0:00 PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0189532689 US-OH-119038 2019-04-16 9-9-05(A)10 Failure to legibly identify well
0834702929 US-OH-129509 2012-01-11 Failure to legibly identify well
0834702929 US-OH-129510 2012-01-11 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[9]