Well Details

Well ID: 34-167-29577
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Newport Township
Operator Name: FQ ENERGY SERVICES LLC
Well Pad ID:
Farm/Lease Name: HELEN F HALL (SWIW #7)
License Status: Active Injection
License Date: 2018-09-04
Spud Date: 2005-04-04
Spud Drilling Contractor: WARREN DRLG
Final Drill Date: 2005-04-12
Well Total Depth: 7303.00 ft
Configuration: Vertical
Latitude: 39.430000
Longitude: -81.310000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-01-26 7434 VIRCO INC Proposed Formation CLINTON/MEDINA Issued Date 1/26/2005 Expired Date 1/26/2006 6:00:00 AM
Inspector Comments Cement Job 2005-04-04 Oil in Injun and 2nd Cow Run. Circulated oil most of cement job. Cement circulated to top then fell back. Will fix when do 4.5" casing.Cement Ticket Notes Inspector Reporting CYNTHIA VAN DYKE
Original Spud 2005-04-04 BASED ON CHIEFS ORDER 2011-
Completed 2005-04-12 BASED ON CHIEFS ORDER 2011-
Reached Total Depth 2005-04-12 BASED ON CHIEFS ORDER 2011-
Completion Report Received 2005-08-10 BASED ON CHIEFS ORDER 2011-
APP 2007-10-17 Proposed Formations:QUEENSTON, Issued Date:10/17/2007, Expired Date:10/16/2008 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:SWD, Proposed Well Class:SWIW
Annulus Pressure Monitoring Approved 2007-11-07 BASED ON CHIEFS ORDER 2011-
Last Compliance Report 2013-10-15 BASED ON CHIEFS ORDER 2011-
Change of Owner 2014-10-24 Operator changed from 7434, VIRCO INC to 8896, GREEN HUNTER WATER LLC
Change of Owner 2016-05-20 Operator changed from 8896, GREEN HUNTER WATER LLC to 9679, FQ ENERGY SERVICES LLC
APP 2018-09-04 Proposed Formations:CLINTON & MEDINA SANDSTONES, Issued Date:9/4/2018, Expired Date:9/3/2020 12:00:00 PM, Drilling unit acres:121.4, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2018-11-26 BASED ON CHIEFS ORDER 2011-
Construction Permit Expires 2020-09-03 BASED ON CHIEFS ORDER 2011-

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-12-22 6985 7122 26
6985 7122 26
6985 7122 26

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 66000 Gal 50000 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 VIRCO INC 4022.00 0.00 152
2006 VIRCO INC 2976.00 0.00 365
2014 VIRCO INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 VIRCO INC Brine 790 152
2006 VIRCO INC Brine 30 365
2014 VIRCO INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-104829324 2014-8-14 0:00: SW No Violations
-1130149776 2008-12-10 0:00 SW No Violations
-1134157528 2015-4-3 0:00:0 SW No Violations
-1266461547 2014-10-27 0:00 SW No Violations
-1274332024 2016-9-14 0:00: SW No Violations
-1374934924 2016-3-2 0:00:0 SW No Violations
-1420167001 2018-5-27 0:00: SW No Violations
-1638843856 2007-11-28 0:00 SW No Violations
-1667679741 2009-10-2 0:00: SW No Violations
-1788497889 2009-12-1 0:00: SW No Violations
-180398040 2005-6-1 0:00:0 PW No Violations
-188503794 2013-3-18 0:00: SW No Violations
-1893577927 2013-4-30 0:00: SW No Violations 2.00
-228424644 2013-9-30 0:00: SW No Violations 2.00
-31122514 2012-12-27 0:00 SW No Violations
-353523669 2016-3-14 0:00: SW No Violations
-353914256 2011-6-17 0:00: PW No Violations 1.00
-354146405 2020-4-20 0:00: SW No Violations
-406002505 2016-11-15 0:00 SW No Violations
-440540296 2008-11-3 0:00: SW No Violations
-548104904 2017-7-24 0:00: SW No Violations
-577179676 2012-6-13 0:00: SW No Violations
-656706744 2009-8-31 0:00: SW No Violations
-814192145 2016-1-8 0:00:0 SW No Violations
-84418336 2017-9-8 0:00:0 SC No Violations
-90346864 2018-4-26 0:00: SW No Violations
-92937718 2018-5-16 0:00: SW No Violations
-939175556 2013-10-1 0:00: SW No Violations 5.00
-990843766 2012-12-20 0:00 SW No Violations 8.00
0006054241 2011-05-24 Salt Water Injection Well No Violations Inspection this day found well in production. 1400# on tubing, 0# on annulus. Location still needs reclamation work - plastic fence still up where the work-over pit was and ground below the facility needs more grass seed - only growing sporadically. Good IDs, unloading pad looks clean and inside dike area mostly dry.
0017729066 2012-05-22 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection but well tender was expecting brine trucks to show up so he could start pump.

Note:Stone needs to be applied to exposed pit liner in tank areas to help prevent decay from sunlight liner is showing signs of fatique due to exposure to the elements.

0031122514 2012-12-27 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that two company owned vacuum tucks were unloading at facility during my inspection.
0064374385 2017-04-05 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and it was noted that two company owned vacuum trucks were unloading at the facility during our inspection.
0084418336 2017-09-08 Surface Facility Construction No Violations Injection pump not in operation during my inspection.

Note: One company owned tanker and one 25-568 vacuum truck unloading at the facility today.

0090346864 2018-04-26 Salt Water Injection Well No Violations

Inspection revealed that injection pump was in operation during my inspection and it was noted that one company owned vacuum truck was offloading at the site during my inspection. Specific gravity on fluid today was noted at 1.060.

0092937718 2018-05-16 Salt Water Injection Well Violations Noted Received phone call from company rep Dave Casto stating that well has equalized and they ceased injection operations,told him to submit repair/plugging plans within 30 days.
0104829324 2014-08-14 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one company owned vacuum truck was unloading at facility during my inspection.
0119009410 2009-02-12 Salt Water Injection Well No Violations Inspection this day found Grant manning the facility - everything looks good, pumps running, 260,000 gal this month already, putting rock on the township and lease road. Quarterly inspection passes - no violations, pad clean.
0165215397 2008-08-13 Completion Testing No Violations Testing pipeline this day - is steel line that has already been buried, pressured up to 2000# with pump - fell 80# over 15 minute period to 1920#. No way to retest tubing/casing pressures unless packer is undone. Ben will call Tom and discuss previous test - failed only due to leaks in fittings of pump truck doing test. Ben called later - says Tom has given permission to use.
0180398040 2005-06-01 Production Wells No Violations Inspection this day found well producing, has not been reclaimed yet, pushed drill mud and cuttings over the hill and into swamp-like depression. Will have Joe look at it.
0188503794 2013-03-18 Salt Water Injection Well No Violations Inspection revealed that well was not in operation during my inspection and according to well tender they were slow receiving water this week.

Note: Unloading pad clean and neat and it was noted that a small building has been placed by unloading to accommodate drivers that visit facility.

0227923874 2010-11-30 Salt Water Injection Well No Violations Service rig runs in remaining tubing in hole to depth of 6829. Baker Hughes man on location to set Baker A-1 Lok-Set Retrievable packer and Universal used to pressure up well. Pump truck took pressure up to 1690, tested their lines, then opened valves to pressure up on well. Immediately fell to 200#, indicating a leak in tubing. Baker set packer, connected to 4.5 casing to see if tubing would flow and it did, also confirming hole in tubing. While pump truck on location, pulled tubing 10 joints at a time, testing pressure after each 10 joints to try and isolate joint with hole. Pulled 50 joints this day without finding problem. Will continue tomorrow.
0228424644 2013-09-30 Salt Water Injection Well No Violations Went by site to check on service rig they were releasing packer and removing from well they will possibly want to start new packer and tubing in well tomorrow afternoon.
0265561816 2009-09-11 Salt Water Injection Well No Violations OEPA Deavers called to say received a call on 9/10/09 about truck dumping brine over the hill off the side of road, oil on the ground, and mans dog sick after drinking the dumped water in the creek. Found area about 3 x 10 showing brine kill, but did not find it to go all the way downhill into the creek, green grass/weeds between the 2 areas. George McIntyre, the complaints came down the road to show me - I agree a small amount of brine was released from truck, small oil spot in middle of road (where truck sat) about 3 x 6 and could be transmission fluid/oil from truck. Says brine was dumped 9/2/09 from an orange and white truck and talked with Grant, monitor at well, to try and determine which truck did it and why. Grant said he would review records and figure out which driver it was and talk to him. Virco has had trouble with this man for many months - has already gone to court once with Virco winning, man claims to be disabled veteran - said his dog still sick from drinking brine - told him to take him to the veterinarian.
0353523669 2016-03-14 Salt Water Injection Well No Violations Baker-Hughes on site to perform chemical treatment on said well.
0353914256 2011-06-17 Production Wells No Violations Inspection this day found orange fence around pit had been taken down, grass growing nicely in area. Still has frac tank by well - believe it should be moved as part of the work-over. Grass starting to grow better in sparse areas below facility where pits were -
0406002505 2016-11-15 Salt Water Injection Well No Violations Inspection today revealed that injection pump was running and it was noted that one company owned vacuum truck was at the site during my inspection.

Note: Roll off box at site needs to be emptied it contains used filters.

0440540296 2008-11-03 Salt Water Injection Well No Violations Inspection this day found well not running - has gauges now on well, working on sign - IDs for well, have not done anything about the un-loading pad or uncovered plastic liner in the pit. Operator at well says they are working on it.
0548104904 2017-07-24 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection and it was noted that rain water has built up in dike area from all of the recent heavy rains told operator to pump water into storage tanks and properly dispose of it down hole.
0577179676 2012-06-13 Salt Water Injection Well No Violations Inspected site at request of UIC Director he received complaint from adjacent landowner of mist from vacuum trucks was killing grass and trees around site, inspected site and found no evidence of such claim.

Note: Stone needs to be applied to exposed liner to help protect it from sunlight it will decay if left exposed and it starts to crack you will be required to replace liners in both storage areas.

0601687622 2016-07-26 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and it was noted that roll off box with the old filters has been removed from site.
0633232447 2010-02-24 Salt Water Injection Well No Violations Inspection this day found pump running attendent at well. Tubing pressure 1450#, 0 on annulus.
0656706744 2009-08-31 Salt Water Injection Well No Violations Inspection this day found Grant on location, no trucks dumping. He says all tanks full, pumping down but well down at this time of visit.
0656845379 2015-06-03 Salt Water Injection Well No Violations On site to witness operator replace vault for unloading/dike drains they remove old plastic type vault and replaced it with a heavy duty concrete one with the capacity of 1000 gallon.
0711433922 2012-02-10 Salt Water Injection Well No Violations My inspection this day due to quarterly requirements. The pump was running and pressures were 1500# on the tubing, 0# on annulus. Two trucks with brine numbers were unloading while I was there. While inspecting the steel flow line from the pump building to the well, found a badly rusted and rotted steel connection - advised them to get it changed out in next few days. Unloading pad clean, good identification, pumphouse clean also. The weather has washed out some of the black plastic used to line the pit when drilled - told them they needed to remove all that plastic - they were instructed to bury it deeply when reclamation was completed. 2/14/12 - Upon inspection, I found the 2 steel line in rusted condition has been replaced with new line. Operator will take propane torch and burn up the plastic found on the ground.
0742017382 2013-06-24 Salt Water Injection Well No Violations Inspection revealed that well is still waiting on service rig to remove tubing and packer from well, they suspect that packer or tubing has lost integrity.
0814192145 2016-01-08 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that two Green Hunter vacuum trucks were unloading at the facility today.
0822283669 2009-09-14 Salt Water Injection Well No Violations Called out this day by Virco to report brine spill. Grant D., caretaker at well, reports when he came to work at 7 AM, George McIntyre was walking nearby/out the drive into the well - when he got to well, found frac tank up at unloading pad, used for extra brine storage, had been drained of 25-30 bbl of brine, that it had run down to the sump hole but it was overflowing due to the large/fast volume to hit it at one time. Brine ran down hill about 200-250 below the sump hole in a path about 10-- Talked with Bob Handshumacker this day - says they are putting up cameras to catch McIntyre. Also says some of the 25-30 bbl went back into tanks/overflow - thinks only about 5 bbls went on ground. Will begin cleaning up today.
0823828476 2016-04-29 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and it was noted that three company owned vacuum trucks were at the facility during my inspection and I discussed with operator that the liner in the containment area needs to have stone reapplied to bare spots on it too help protect it from the sunlight.
0833120455 2015-04-03 Brine Hauler No Violations On site with UIC Inspector Dave Ball, 1 Brine Truck on site. GreenHunter Water LLC (UIC #25-463) Labeled properly and approved to haul to the Helen Hall well.
0859432696 2010-08-23 Salt Water Injection Well No Violations Inspection this day found new man at facility - Jay Satterfield. Pump was running, no trucks in, tubing pressure was 1650#, annulus was 30#. Good IDs, starting to fade, all looked good. Flowmeter reading in gal.
0864095042 2009-05-27 Salt Water Injection Well No Violations Inspection this day found well in operation, all looks good.
0913013303 2011-02-24 Salt Water Injection Well No Violations Inspection this day found everything in order. Pump running, pumping down tanks with pressure at 1600#, 0# on annulus. Pointed out getting close to limits and operator said office has sent samples in to get top pressure increased. Fresh water in dike area due to recent rains - should be out in next day or 2.
0939175556 2013-10-01 Salt Water Injection Well No Violations On site to witness changing out of tubing and packer Baker Tool Reps on site to start new A-3-Set Lock in well and once they reach 6850 they will attempt to set packer and once set they will J off of packer and circulate inhibitor and pressure test annulus@1660 psi and monitor for required time period.
0990843766 2012-12-20 Salt Water Injection Well No Violations On site to witness Producers Services perform acid job on said well they pumped 500 gal of 15%acid into formation and they let it soak for 30 minutes and then we pumped brine at 1.3 bpm and monitored pressures with 1570 psi noted as top pressure recorded.
1057563087 2010-12-02 Salt Water Injection Well No Violations Ran in remaining tubing, pressure testing it as it went in. Found no more leaks. Universal pressured up on well to 1730#, held 20 min. pressure falling to 1670#, then set packer, pressured up on tubing to 1685#, held 20 min., with pressure falling to 1609#. Passed integrity test, well put back into operation.
1093491983 2016-10-14 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
1107498199 2010-12-21 Salt Water Injection Well No Violations Complaint from Mr. McIntire across the road that brine trucks leaving valves open as driving down the road - has pictures to give to AGs from last Thurs, he says. As I drove the roads to facilty, saw no sign of melted snow from brine, no damage at all. Talked to Jay at site and asked if they were leaving valves open - he did not believe so. Got a complaint last week from OEPA from Mr. McIntire that dumping brine on roads - called and found out they were having to transfer brine from big trucks to short trucks at end of road - possibly a small amount from that procedure but today saw no kill area or melted snow at end of road where occurred. Explained to Mr. McIntire that insugnificant amounts were not regulated, that with a permit companies were allowed to spread brine on roads. Told him I was concerned over 10 bbl being dumped but not a gallon at a time. He got very angry, continues to complain about the facility across the road from the house he rents. I saw no problem this day.
1107543020 2019-7-22 0:00: SW No Violations
1123697678 2011-05-24 Preliminary Restoration Violations Noted Minor reclamation still needs completed on site due to recent tubing/packer work. The plastic fence is still up around where pit was located. The site needs final grading and additional seeding, especially where drill pit and other excavation occurred. There is a frac tank still on location, near the well, which should be removed. 11/21/11 - Frac tank has been removed and the site has been reclaimed from recent work-over on the well. All violations RESOLVED.
1130149776 2008-12-10 Salt Water Injection Well No Violations Inspection this day found unloading pad is complete - concrete with side curbs and looks very good. Gauges, IDs up at well, still only need to do something about the exposed plastic.
1130592022 2005-06-15 Preliminary Restoration No Violations Inspection this day found location had been reclaimed, has been seeded and mulched, still small amount of black plastic from the pit didnt get buried as did several of the plastic collar protectors from the casing that was run. Will ask them to remove. Well producing, current chart in meter, GPSd locations at earlier date.
1134157528 2015-04-03 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one company owned vacuum truck was unloading at the site during my inspection.
1184222353 2013-05-08 Salt Water Injection Well No Violations Pressures equalizing shut down for repair, trying to get service rig and new tubing and packer ordered and as soon as they get equipment they will repair well and pressure test as required.
119009410 2009-2-12 0:00: SW No Violations
1190896581 2007-09-28 Salt Water Injection Well No Violations Inspection this day required to run packer into new disposal well. New Baker J or tension packer run into hole on new 2 3/8 tubing to 6926. Baker man on location to supervise running of packer. Water well in use - landowner estimated it 40 deep, at GPS N39.43571, W81.31373. Also water well further away at GPS N39.43188, W81.31466, in use. Tanks will be set on top of hill, about 150 from well - further downhill from well about 200 is a low, usually swampy drainage area coming off the rolling hills. Will try and take a couple pictures. This day spent running tubing and packer to 6926, then loaded the tubing slowly with fresh water but still too much air in it at 6:30 PM to complete the pressure test this day. 9/28 - Returned to find air out of tubing, ran pressure up to 1775# with pump truck, after 15 min. was at 1650#. Passed. Next sheared pins off bottom of packer with 2700#, circulated to make sure packer open, then filled with packer inhibitor. Set packer at 6926, tested annulurs to 525# for 15 min. No drop in pressure. Completed volume/rate tests that showed at 1 bbl/min, needed 700#, 1/4 bbl/min, needed 50#. All were satisfied.
1213197337 2008-06-11 Salt Water Injection Well No Violations Inspection this day found construction of building for pump has been started - still framing. 8 big tanks in place with dike lined with heavy plastic, then stone on top. Some lines in place, drain at pad - making progress, says will be another month.
1227190167 2008-11-19 Salt Water Injection Well No Violations Inspection this day found attendent on hand, working on framing up the unloading pad to pour concrete. Pump house clean, pump not running. Have plans to put felt over the exposed plastic around edges of dike to prevent UV damage. All looked good. Ids up at well, new gauges. Volume is being measured in gallons and will be zerod each month.
1231355990 2009-01-06 Salt Water Injection Well No Violations Went by well as right across the road on oil spill clean-up. All looks in order, no trucks unloading, operator on site for incoming water. Unloading pad looks great, very clean.
1266461547 2014-10-27 Salt Water Injection Well No Violations Injection pump not in operation during my inspection and it was noted that old plastic vault was showing signs of needing replaced and I told operator if vault is replaced they will need to install a one piece concrete vault and contact inspector prior too doing so.
1274332024 2016-09-14 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection and it was noted that two GreenHunter vacuum trucks were unloading at the facility today.
1284143445 2010-05-24 Salt Water Injection Well No Violations Inspection this day found Bob Handshumaker and helper performing maintanence on the pumps, other equipment. Pump not running, no problems, good IDs.
1290430992 2010-01-19 Administrative Inspection No Violations Ben Smeltzer called to say integrity has failed - they have shut down well and bled off pressure. Will pull tubing, packer Tues with Baker man, plan on rebuilding packer, then running back in 1st week in Dec. Notified Columbus.
1322058841 2011-11-21 Salt Water Injection Well No Violations Inspection this day found well equipped with a pumping unit and in production. Identification sign at well damaged by the cows. Owner said they will install new ones today. Tank and facility appear in good condition. Pooled water in some areas due to heavy rain. The frac tank that was between the well and the building has finally been removed. Violations are all RESOLVED.
1343596591 2012-07-27 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: Owner has applied adhesive to exposed portion of liner and has applied stone to it too help prevent decay due to exposure to sunlight.

1350339571 2012-10-15 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection, it was noted that annulus of tubing was at zero pressure and I suggested to operator to have positive pressure applied to annulus ASAP.


Note: Select Energy vac truck was unloading at facility during my inspectionUIC#359.

1354236163 2012-11-28 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that two Select Energy vacuum trucks were on unloading pad during my inspection.
1355345832 2012-12-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and two company owned vacuum trucks were unloading at facility during my inspection.

Note: Pump house interior was clean and neat and there was no fresh water built up in dike area.

1358376334 2013-01-16 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it as noted that one Green Hunter vacuum truck was unloading at facility this inspection.

Note: Fresh water build up in dike area told well operator to have excess water removed and properly disposed of.

1372130125 2016-03-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED
1374934924 2016-03-02 Salt Water Injection Well No Violations Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 2nd, 3rd & 4th quarter of 2015 despite a letter that was sent with a deadline of February 29, 2016. Please submit the appropriate reports by March 16th, 2016. REPORTS RECEIVED 3/8/2016.
1381103088 2013-10-03 Salt Water Injection Well No Violations On site to witness Baker A-3 set lock run into well and pressure test annulus of tubing Producers Services pumped 72 bbl of fresh water fluid with 10 gal of inhibitor and they pressured tested annulus @ 1980 psi with no decline in pressure and we also tested tubing @ 2000 psi which that is what it took to release plug on bottom of packer.

Note: Setting depth of new packer is 6891 to center of element and overall length of string is 6894.

1383779959 2013-11-06 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that one Green Hunter vacuum truck was unloading at facility during my inspection.
1386109642 2013-12-02 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
1388534086 2013-12-30 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that two Green Hunter vacuum trucks were unloading at facility during my inspection.
1397244766 2014-04-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that two company owned vacuum trucks were unloading at facility during my inspection.

Note: Owner is planning on changing out injection pump in the near future.

1417610449 2010-11-19 Administrative Inspection No Violations Ben Smeltzer called to say integrity of disposal well had failed. They are shut down - have bled off pressure and will pull tubing and packer on 11/23/2010 with Baker man present. Packer will be rebuilt and run back in week of Dec. 1st. Notified Columbus.
1420167001 2018-05-27 Salt Water Injection Well No Violations Inspection revealed that well is currently shut in awaiting on plan to be submitted for repair/plug.
1424356735 2010-11-29 Salt Water Injection Well No Violations Ben Smeltzer called to say they had lost integrity of well on 11/19/10 - are bleeding well down. Tubing and packer pulled with Baker man present on 11/22/10 - packer taken to be rebuilt. This day found crew and rig running rebuilt packer, tubing back in hole. Witnessed packer going in hole. Will pressure test tomorrow.
1456863802 2016-03-01 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and it was noted that one company owned tanker truck was unloading at the facility during my inspection.
1464970211 2016-06-02 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation prior to Baker Hughes performing acid treatment job on said well.

Note: Four Green Hunter tanker trucks were unloading at the facility during my time on site.

1486053804 2017-02-02 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and dike area was clear of fluid and it was noted that one company owned vacuum truck was unloading at the facility during my inspection.
1515699694 2018-01-09 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection and it was noted that one company owned vacuum truck was offloading during my inspection.
1550174575 2018-02-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. REPORTS RECEIVED BY THE DIVISION ON FEBRUARY 26, 2018
1550254461 2019-02-14 Salt Water Injection Well No Violations Inspection revealed that well is still down waiting on repair or possible plugging of the well.


Note: Fresh water has built up in tank area, called company rep and requested that they remove water to allow for volume in the event of spill.

1571062469 2010-12-01 Salt Water Injection Well No Violations Continuing to pull tubing, 10 joints at a time and testing pressure to try and find leak. None found up to now.
1572126765 2019-10-25 0:00 SW No Violations
1581503194 2015-03-20 Salt Water Injection Well No Violations Producers Services on site to perform 2000 acid treatment on said well they pumped 1000 gallon of acid and displaced it into formation and let soak for one hour and then pumped remaining 1000 gallon and displaced it into formation again and let soak for one additional hour before placing well back into operation.
1583392514 2008-08-18 Salt Water Injection Well No Violations First inspection since approval to use. Well down when arrived - tubing pressure at 300#, annulus 0, operator arrived and started pump and was taking water at 585# before I left. Location still needs little cleaning up, good IDs on tank, should also have some at well.
1638843856 2007-11-28 Salt Water Injection Well No Violations Performed annulus test this day. Pressured up with pump truck to 1775# between 4.5 casing and tubing - in 15 min. fell only to 1765#. Dropped 10# - passed.
165215397 2008-8-13 0:00: CT No Violations
1667679741 2009-10-02 Salt Water Injection Well No Violations Inspection this day found brine spill had been cleaned up - grass growing nicely downhill from the pump that ran over due to neighbor opening tank. Still small area about 2 x 6 that needs more lime, have seeded it but nothing growing yet. Now have cameras up to observe any intruders.
1676913103 2013-08-21 Salt Water Injection Well No Violations Well is down waiting on service rig to replace tubing and packer.
1766980917 2018-07-19 Salt Water Injection Well No Violations Well is down for repair.
17729066 2012-5-22 0:00: SW No Violations
1788497889 2009-12-01 Salt Water Injection Well No Violations Inspection this day found pump running, pressures read 1600# on tubing, 0# on annulus. New employee Matt McElfresh on site, total water for 10/09 was 5765 bbl.
1893577927 2013-04-30 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that operator was weed eating and mowing around facility during my inspection.

Note: Facility in satisfactory condition this inspection.

2109535211 2014-06-16 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection but it was noted that three company owned vacuum trucks were unloading at facility during my inspection.
227923874 2010-11-30 0:00 SW No Violations 8.00
265561816 2009-9-11 0:00: SW No Violations
556044994 2019-9-5 0:00:0 SW No Violations
601687622 2016-7-26 0:00: SW No Violations
6054241 2011-5-24 0:00: SW No Violations 1.00
633232447 2010-2-24 0:00: SW No Violations
64374385 2017-4-5 0:00:0 SW No Violations
656845379 2015-6-3 0:00:0 SW No Violations
711433922 2012-2-10 0:00: SW No Violations 1.00
742017382 2013-6-24 0:00: SW No Violations
822283669 2009-9-14 0:00: SW No Violations
823828476 2016-4-29 0:00: SW No Violations
833120455 2015-4-3 0:00:0 BH No Violations
859432696 2010-8-23 0:00: SW No Violations
864095042 2009-5-27 0:00: SW No Violations
913013303 2011-2-24 0:00: SW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0092937718 US-OH-130626 2018-08-03 9-3-07(H) Mechanical failure/contamination
1123697678 US-OH-103121 2011-05-24 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)
1372130125 US-OH-110998 2016-04-04 Failure to file salt water injection annual report
1550174575 US-OH-114913 2018-03-27 NONE Failure to report disposal fees