34-167-29629

Well Details

Well ID: 34-167-29629
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Aurelius Township
Operator Name: GENESIS RESOURCES LLC
Well Pad ID:
Farm/Lease Name: B & N COAL/MM
License Status: Producing
License Date: 2006-12-20
Spud Date: 2007-04-03
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 2007-04-09
Well Total Depth: 2100.00 ft
Configuration: Vertical
Latitude: 39.590000
Longitude: -81.420000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-12-20 Proposed Formations:BEREA-GORDON, Issued Date:12/20/2006, Expired Date:12/20/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-04-09
Reached Total Depth 2007-04-09
Completion Report Received 2007-07-17
Construction Permit Expires 2007-12-20
Change of Owner 2015-07-10 Operator changed from 6288, ALLIANCE PETROLEUM CORPORATION to 9086, GENESIS RESOURCES LLC
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-10-31 1636 1684 10
2007-10-31 1538 1546 20
1538 1546 20
1636 1684 10
1758 1804 10
1889 1937 20
1538 1546 20
2007-10-31 1889 1937 20
2007-10-31 1758 1804 10

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2000 Gal 0 GANTZ, THIRTY FOOT, & GORDON SANDS WERE INVOLVED IN THIS FRAC TREATMENT.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 ALLIANCE PETROLEUM CORPORATION 1027.00 14.00 365
2013 ALLIANCE PETROLEUM CORPORATION 1169.00 28.00 365
2014 ALLIANCE PETROLEUM CORPORATION 931.00 6.00 365
2015 ALLIANCE PETROLEUM CORPORATION 595.00 8.00 181
2016 GENESIS RESOURCES LLC 1098.00 6.00 298
2017 GENESIS RESOURCES LLC 895.00 0.00 301

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2013 ALLIANCE PETROLEUM CORPORATION Brine 10 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 9 365
2015 GENESIS RESOURCES LLC Brine 0 184
2016 GENESIS RESOURCES LLC Brine 0 298
2017 GENESIS RESOURCES LLC Brine 0 301

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1368049347 2007-8-24 0:00: PL No Violations
-1718684839 2009-9-16 0:00: PW No Violations
-1781379572 2017-4-11 0:00: PW No Violations 1.20
-2061066357 2020-8-26 0:00: PW No Violations 0.40
-907720118 2017-1-25 0:00: PW No Violations 1.00
0201587502 2017-01-12 Production Wells No Violations The gas leak at the wellhead was corrected, however no work on the brine scald was completed at the date and time of this inspection.
0340655864 2016-12-27 Administrative Inspection No Violations Called company to notify them of compliance notice and explain my findings. They said they would start right away cleaining up the spill.
0512527107 2017-01-27 Production Wells No Violations Follow up on this well found that the 2 inch was still leaking. I again called Andrew and this time I explained that I would wait here till someone came to fix the leak. He called back and said that his pumper was in West Virginia and couldnt get there until near 3.
0907720118 2017-01-25 Production Wells No Violations This follow up inspection found that the gas leaking from the 1/4 inch pipe at the well-head was corrected. However the brine contamination in the dike and outside the dike was still untouched. The 2 inch diameter pipe where a plug is screwed into the tee was found to be actively leaking. I called Andrew with Genesis Resources to find out what was going on. He said that the pumper stated it was cleaned up. I informed him that it wasnt and that the pipe was actively leaking. He said that he would get someone on it right now.
0994956221 2016-12-27 Production Wells Violations Noted When I pulled off the road I could smell natural gas. As I neared the well I could hear the leak as well as smell it stronger. Inspection of the well found a plug to be leaking in the end of a 1/4 valve. Inspection of the tank battery found 2-210 barrel tanks and 2 small 40 barrel plastic tanks. The dike also contained 2 separators. The lower corner of the dike by a tank drain contained water. The soil in this area looked different. This was by the tank labeled 995. This water was noted on the outside of the dike going toward the road ditch. There was a swath of ground approximately 18 wide void of vegetation where the water from the dike was running. A field test of this water with Quantabs maxed out the low range ones inside and outside the dike. I then tested with high range Quantabs from Lot # 4430 which also maxed out. These high level Quantabs tested to 6171 PPM chlorides at 8.6. Pictures were taken. Gas leak needs corrected, brine contaminated soils need removed and disposed of in a proper manner. Uncontaminated soil will be needed to replace contaminated soil removed and location needs seeded and mulched to establish vegetation.
1368049347 2007-08-24 Preliminary Restoration No Violations Inspection this day found well producing with jack, tanks for 6 wells, has good IDs, good dike, current chart in meter, location has been reclaimed, grass growing, lookds good!
1525710543 2018-05-01 Production Wells No Violations I am accompanied by Regional Supervisor Dan Goins. Our inspection found the well is equipped with a pumping unit. The pumping unit has no motor or engine. The tank battery is equipped with two 210 barrel tanks, two 50 barrel plastic tanks, two separators and two orifice meters.
1718684839 2009-09-16 Production Wells No Violations Inspection this day found well producing with jack, tank has ID sticker but no info - call secretary and asked her to get some better pens for the pumpers, current chart in meter, good dike.
1781379572 2017-04-11 Production Wells No Violations Violations have been resolved. Site is remediated and gas leak has been fixed.
201587502 2017-1-12 0:00: PW No Violations 1.50
340655864 2016-12-27 0:00 AM No Violations 0.30
512527107 2017-1-27 0:00: PW No Violations 1.50
994956221 2016-12-27 0:00 PW No Violations 2.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0994956221 US-OH-131417 2017-01-06 9-1-07 Well operation causing pollution and contamination
0994956221 US-OH-131418 2017-01-06 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas
0994956221 US-OH-131419 2017-01-06 NONE(B) Dike or pit not able to prevent escape of brine or other wastes
0994956221 US-OH-131420 2017-01-06 NONE[C] Failure to keep dike or pit free of brine or other wastes

For data sources see[9]