If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-167-29667 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.32,"lon":-81.81,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Washington | |
Municipality: Decatur Township | |
Operator Name: RIVER VALLEY ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: KIDDER UNIT | |
License Status: Producing | |
License Date: 2008-06-26 | |
Spud Date: 2008-09-30 | |
Spud Drilling Contractor: FMS DRILLING | |
Final Drill Date: 2008-10-05 | |
Well Total Depth: 4000.00 ft | |
Configuration: Vertical | |
Latitude: 39.320000 | |
Longitude: -81.810000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-06-26 | Proposed Formations:ORISKANY/SHALE/BEREA, Issued Date:6/26/2008, Expired Date:6/26/2009 6:00:00 AM, Drilling unit acres:30, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-10-05 | |
Completion Report Received | 2009-03-18 | |
Construction Permit Expires | 2009-06-26 | |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-06-10 | 2994 | 3292 | 17 |
2009-06-10 | 3716 | 3792 | 15 |
2994 | 3292 | 17 | |
3716 | 3792 | 15 | |
3898 | 3938 | 15 | |
2994 | 3292 | 17 | |
2009-06-10 | 3898 | 3938 | 15 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 0 | 2ND STAGE OF FRAC JOB | ||
H2O | 0 | 0 | 0 | 3RD STAGE OF FRAC JOB | ||
H2O | 0 | 142480 Gal | 90000 | 1ST STAGE OF 3-STAGE FRAC JOB … ONLY A SINGLE SET OF FRAC TREATMENT VOLUMES & PRESSURES AND RESERVOIR PRESSURES WERE REPORTED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | RIVER VALLEY ENERGY INC | 0.00 | 0.00 | 365 |
2009 | RIVER VALLEY ENERGY INC | 1695.00 | 0.00 | 365 |
2010 | RIVER VALLEY ENERGY INC | 1865.00 | 0.00 | 365 |
2011 | RIVER VALLEY ENERGY INC | 1859.00 | 0.00 | 0 |
2012 | RIVER VALLEY ENERGY INC | 1756.00 | 0.00 | 366 |
2013 | RIVER VALLEY ENERGY INC | 799.00 | 0.00 | 365 |
2014 | RIVER VALLEY ENERGY INC | 488.00 | 0.00 | 365 |
2015 | RIVER VALLEY ENERGY INC | 623.00 | 0.00 | 365 |
2016 | RIVER VALLEY ENERGY INC | 459.00 | 0.00 | 365 |
2017 | RIVER VALLEY ENERGY INC | 713.00 | 25.00 | 365 |
2018 | RIVER VALLEY ENERGY INC | 573.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | RIVER VALLEY ENERGY INC | Brine | 55 | 365 |
2009 | RIVER VALLEY ENERGY INC | Brine | 496 | 365 |
2010 | RIVER VALLEY ENERGY INC | Brine | 241 | 365 |
2011 | RIVER VALLEY ENERGY INC | Brine | 80 | |
2012 | RIVER VALLEY ENERGY INC | Brine | 146 | 366 |
2013 | RIVER VALLEY ENERGY INC | Brine | 0 | 365 |
2014 | RIVER VALLEY ENERGY INC | Brine | 0 | 365 |
2015 | RIVER VALLEY ENERGY INC | Brine | 0 | 365 |
2016 | RIVER VALLEY ENERGY INC | Brine | 80 | 365 |
2017 | RIVER VALLEY ENERGY INC | Brine | 270 | 365 |
2018 | RIVER VALLEY ENERGY INC | Brine | 80 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1315677809 | 2017-8-28 0:00: | PW | No Violations | |
-75373028 | 2008-12-3 0:00: | PL | No Violations | |
0075373028 | 2008-12-03 | Preliminary Restoration | No Violations | Not ready for reclamation inspection - crew working this day on tank, lines, meter. |
1315677809 | 2017-08-28 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with a pumping unit, a 4 1/2 inch diameter production casing, 1 1/2 inch diameter production tubing, and a hook up for domestic gas. The valves are open on the wellhead at the time of inspection. The tank battery for this well is equipped with a 100 barrel steel tank, a 50 barrel plastic tank with proper identification on it, a meter with a chart in it, and a vertical separator. There are no issues to report at this time and the well is in production at the time of inspection. |
1481259044 | 2017-08-28 | Preliminary Restoration | No Violations | The inspection this day revealed that this well has vegetation established, erosion has been controlled, the pit has been closed, and the well is in production at the time of inspection. There are no issues to report and the well has passed preliminary restoration. |
For data sources see[9]