If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-167-29719 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.4,"lon":-81.22,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Washington | |
Municipality: Newport Township | |
Operator Name: OOGC DISPOSAL COMPANY 1 LLC | |
Well Pad ID: | |
Farm/Lease Name: SAWMILL RUN DISPOSAL (SWIW #10) | |
License Status: Active Injection | |
License Date: 2020-02-14 | |
Spud Date: 2013-02-13 | |
Spud Drilling Contractor: PRECISION DRILLING | |
Final Drill Date: 2013-03-03 | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 39.400000 | |
Longitude: -81.220000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-11-13 | Proposed Formations:CLINTON-MEDINA, Issued Date:11/13/2012, Expired Date:11/13/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Reached Total Depth | 2013-03-03 | |
Completion Report Received | 2013-08-26 | |
Annulus Pressure Monitoring Approved | 2014-07-18 | |
Last Compliance Report | 2014-07-24 | |
Change of Owner | 2015-11-24 | Operator changed from 2153, OOGC DISPOSAL CO 1 LLC to 9503, OOGC DISPOSAL COMPANY 1 LLC |
APP | 2019-05-17 | Proposed Formations:SALINA C UNIT (SANDSTONE), Issued Date:5/17/2019, Expired Date:5/16/2021 12:00:00 PM, Drilling unit acres:15.991, Proposed Well Type:SWD, Proposed Well Class: |
Record Last Modified | 2019-05-24 | |
Construction Permit Expires | 2021-05-16 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-07-24 | 7248 | 7263 | 0 |
7248 | 7263 | 0 | |
7248 | 7263 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-04-18 | H2O | 15 | 1413 Bbl | 16344 | BAKER-HUGHES | |
2014-07-18 | ACID | 0 | 51381 Gal | 0 | Producers Service Corporation | Clinton formation seams to be tight.
Medina section is possibly good injection zone. |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1025531402 | 2019-10-10 0:00 | SW | No Violations | |
-1083255700 | 2017-10-24 0:00 | SW | No Violations | |
-1098502334 | 2019-12-3 0:00: | PB | No Violations | |
-1104192574 | 2019-8-26 0:00: | SW | No Violations | |
-1106409303 | 2019-12-6 0:00: | PB | No Violations | 12.00 |
-1185538084 | 2018-2-16 0:00: | SW | No Violations | |
-1206429436 | 2016-1-8 0:00:0 | SW | No Violations | |
-1326551904 | 2018-3-27 0:00: | SW | No Violations | |
-1354719700 | 2016-11-15 0:00 | SW | No Violations | |
-1405879945 | 2019-7-22 0:00: | SW | No Violations | |
-1494808018 | 2019-3-25 0:00: | SW | No Violations | |
-1550706580 | 2014-6-24 0:00: | SW | No Violations | |
-162834766 | 2016-7-26 0:00: | SW | No Violations | |
-1638383744 | 2013-12-2 0:00: | SW | No Violations | |
-1687696078 | 2016-6-6 0:00:0 | SW | No Violations | |
-172288203 | 2017-11-15 0:00 | SW | No Violations | |
-1727551462 | 2013-2-15 0:00: | SW | No Violations | |
-1833413072 | 2017-4-5 0:00:0 | SW | No Violations | |
-1836284607 | 2013-12-13 0:00 | SW | No Violations | |
-184683819 | 2019-10-16 0:00 | PB | No Violations | |
-1882999581 | 2014-6-17 0:00: | SW | No Violations | |
-1887890385 | 2019-10-22 0:00 | SW | No Violations | |
-1893786811 | 2020-6-30 0:00: | SW | No Violations | |
-196296034 | 2014-5-5 0:00:0 | SW | No Violations | |
-1974930350 | 2015-3-18 0:00: | SW | No Violations | |
-2095607429 | 2014-7-22 0:00: | PL | No Violations | |
-2113170097 | 2013-12-30 0:00 | SW | No Violations | |
-254124757 | 2019-10-24 0:00 | SW | No Violations | |
-29850451 | 2017-5-31 0:00: | SW | No Violations | |
-413652614 | 2014-1-6 0:00:0 | SW | No Violations | |
-484132147 | 2013-10-1 0:00: | SW | No Violations | |
-486016694 | 2019-10-8 0:00: | PB | No Violations | |
-50638916 | 2019-10-30 0:00 | PB | No Violations | 12.00 |
-544143039 | 2013-9-12 0:00: | SW | No Violations | |
-564960393 | 2020-1-15 0:00: | PB | No Violations | |
-61173572 | 2014-4-10 0:00: | SW | No Violations | |
-752604507 | 2014-7-30 0:00: | SW | No Violations | |
-801586133 | 2019-12-9 0:00: | PB | No Violations | |
-855684924 | 2017-7-24 0:00: | SW | No Violations | |
-868183927 | 2014-7-15 0:00: | SW | No Violations | 8.00 |
-944884246 | 2019-10-25 0:00 | PB | No Violations | |
0029850451 | 2017-05-31 | Salt Water Injection Well | No Violations | Inspection revealed that that well was not in operation during my inspection. |
0061173572 | 2014-04-10 | Salt Water Injection Well | No Violations | Inspection revealed that well is still down waiting on company to submit workover plan or plug said well. |
0074355347 | 2013-08-21 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that two Ohio Oil Gathering trucks were unloading at temporary storage facility during my inspection. |
0096115455 | 2013-11-20 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation and it was noted that liner from temporary storage site is being removed and hauled to a approved landfill. |
0162834766 | 2016-07-26 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump too this well was in operation today. |
0172288203 | 2017-11-15 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump to this well was in operation on the day of my inspection. |
0178828093 | 2017-02-01 | Salt Water Injection Well | No Violations | Inspection revealed that well was not in operation during my inspection and currently owner is not using well much because of high pressure issues, injection zones in this area are tight Clinton/Medina. |
0194000599 | 2018-01-09 | Salt Water Injection Well | No Violations | Inspection revealed that well appears not to be in service at this time. |
0196296034 | 2014-05-05 | Salt Water Injection Well | No Violations | Inspection revealed that well is still down waiting on plan to correct equalization issues. |
0269218046 | 2014-06-16 | Salt Water Injection Well | No Violations | Inspection revealed that service rig was on site and mixing kill fluid in preparation to release packer and remove it from well bore and once this task is completed they plan on placing liner string in open hole section of well bore. |
0368935874 | 2013-03-01 | Salt Water Injection Well | No Violations | Inspection revealed that Precision Drilling was at a depth of 7330 and were preparing to trip drill bit and install new 6.250 tri-cone bit to finish drilling well with. |
0413652614 | 2014-01-06 | Salt Water Injection Well | No Violations | Inspection revealed that well is down to high injection pressure issues in conversation with operator stating that owner may want to deepen well to find a more suitable injection zone. |
0484132147 | 2013-10-01 | Salt Water Injection Well | No Violations | Injection pump not running today and they were performing pressure testing of new 4 fiber spar flow line they pressured up to 3450 psi and will monitor pressure for eight hours. |
0544143039 | 2013-09-12 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that injection line to facility is nearly completed and should be ready for pressure testing in the near future. |
0747030739 | 2014-06-26 | Salt Water Injection Well | No Violations | Inspection revealed that Forbes Service rig was on site washing fill up in open hole section of well to bottom and once well bore is clean they will attempt to run liner string to bottom. |
0752604507 | 2014-07-30 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that temporary storage tanks at site are being cleaned and once clean they will return them to rental company. |
0766412508 | 2013-02-22 | Salt Water Injection Well | No Violations | Stopped by drilling rig for update they were drill@4750 with 8.750 bit and were planning on drilling to 7200 and run 7 casing in this section of well. |
0767143750 | 2019-02-28 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump to this well was in operation during my inspection.
Note: Annulus pressure on tubing has dropped to zero will contact company and request pressure be applied to it. |
0807598334 | 2018-05-27 | Salt Water Injection Well | No Violations | Inspection revealed that well does not appear to be used much at this time. |
0855684924 | 2017-07-24 | Salt Water Injection Well | No Violations | Inspection today indicated that well was not being used today. |
0868183927 | 2014-07-15 | Salt Water Injection Well | No Violations | On site to witness rig crew run 4.5 casing in well and pressure test annulus and owner is preparing to perform small frack on well later this week.
Note: Packer is set at 7020 and is set in compression and there is 131 bbl of water and 30 gallon of inhibitor in annular space. |
0904552061 | 2013-08-21 | Salt Water Injection Well | No Violations | Injection pump in operation at the time of inspection. There was some fluid inside the dike during my visit. I told a truck driver about it and he dipped it out with a bucket and put it in a tank. Everything is in good working order. |
1083255700 | 2017-10-24 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump to this well was not in operation during my inspection. |
1093358842 | 2013-11-06 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that storage tanks at temporary storage facility has been removed and liner and other materials still need to be removed from site.
Note: Annulus pressure is above pressure noted on last inspection it appears that annulus fluid is foaming up and creating pressure. |
110081571 | 2019-10-26 0:00 | PB | No Violations | |
114472874 | 2019-11-17 0:00 | PB | No Violations | 10.00 |
1156016043 | 2019-11-14 0:00 | PB | No Violations | |
1185538084 | 2018-02-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. FEES AND REPORTS RECEIVED 3/9/2018 |
1206429436 | 2016-01-08 | Salt Water Injection Well | No Violations | Inspection revealed that well is not used much at this time. |
1263706718 | 2015-06-08 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation but it appears that it is not used much at this time. |
1317698417 | 2019-12-10 0:00 | PB | No Violations | |
1326551904 | 2018-03-27 | Salt Water Injection Well | No Violations | Well not being used much at this time. |
1328090560 | 2014-08-14 | Salt Water Injection Well | No Violations | Inspection revealed that injection pressure has reached maximum level and there was three technicians on site plumbing valves on well head. |
1354073107 | 2015-08-13 | Salt Water Injection Well | No Violations | Inspection revealed that well is not used much at this time. |
1354719700 | 2016-11-15 | Salt Water Injection Well | No Violations | Well not in operation at this time. |
1360620920 | 2013-02-11 | Drill / Deepen / Reopen | No Violations | On site with company rep to discuss casing program for well and inspect E&S plan as location is being built and they plan on having conductor rig on site by the end of week. |
1361117002 | 2013-02-16 | Drill / Deepen / Reopen | No Violations | On site to witness casing job and cementing of casing,Precision Drilling ran 504 of 13.375 and Baker Hughes cemented it in place with 400 sacks of Class 1 cement with 20 bbls of good returns. |
1361823271 | 2013-02-25 | Salt Water Injection Well | No Violations | Present depth@7252 coming out of hole to run wireline log and then run 7 casing and cement it in place. |
1361914534 | 2013-02-26 | Salt Water Injection Well | No Violations | On site to witness running and cementing of 7 casing string Precision drilling ran 7222 of 26# casing and 1-cementing shoe and 10-centrilizers and 1-float collar and 1-stage tool while landing 7 casing they plugged shoe and we had to get a set of 7 elevators and long bails to move pipe upward and once they established circulation decision was made to circulate hole with drilling mud be fore we cemented pipe in place.
Baker Hughes cemented first stage with 285 sacks of 50/50 POZ MIX. |
1362089676 | 2013-02-28 | Salt Water Injection Well | No Violations | On site to witness Baker Hughes wireline truck bond log 7 casing string . |
1363216637 | 2013-03-13 | Salt Water Injection Well | No Violations | Inspection revealed that well has been drilled and not completed at this time in conversation with company rep stating they plan on performing testing on well in early April. |
1366326217 | 2013-04-18 | Drill / Deepen / Reopen | No Violations | I went to the location today to witness the frac job. Having too many technical difficulties prevented them from finishing the job by the time I left the location. 12 barrels of acid and 846 lbs. of sand had been pumped. There was a total of 363.8 barrels of slurry that was pumped downhole. Well was shut in at 1584 psi. |
1366828136 | 2013-04-23 | Completion Testing | No Violations | On site to witness acid job being preformed on said well Baker Hughes pumped 1000 gal of 28% acid at 5 bpm at 1930 psi and ISIP was 1750 psi and 5 min was 1700 psi and 15 min was 1690 and still falling we will start packer and tubing in well tomorrow. |
1366894658 | 2013-04-24 | Salt Water Injection Well | No Violations | On site to witness Packer and tubing run in well Key Energy service rig preformed work they ran 2100 of pipe today and will resume operations at daylight in the morning. |
1367067230 | 2013-04-25 | Salt Water Injection Well | No Violations | On site to witness running of 4.5 tubing and packer in hole and pressure tested.
Key Energy Services preformed work at site, they ran 7175 of casing and we pressure tested @2020psi and it held(TEST PASSED),Baker Hughes pumped 134 bbl of inhibitor laden fluid in annulus of well. Note: Kline packer stainless steel and it was set under 32K compression. |
1367882907 | 2013-05-06 | Salt Water Injection Well | No Violations | Key Energy Services back on site to repair mandrel type wellhead and Baker Hughes was on site with pump truck to retest annulus of tubing once we fixed wellhead,packer is set under 32K compression and string weight of tubing is 83K. |
1372106345 | 2013-06-24 | Salt Water Injection Well | No Violations | On site to witness start up of injection well, owner has placed 10-500 bbl tanks in temporary containment and placed injection pump and generator at site to perform testing on injection zone they hope to perform pressure falloff test by weeks end. |
1372712983 | 2013-06-28 | Salt Water Injection Well | No Violations | On site to witness Blue Dot Services set down hole digital pressure gauges inside of injection string@7160 and pressure on tubing prior to setting gauges was 1790 psi. |
1373590724 | 2013-07-10 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that two company owned tankers were unloading at the site during my inspection. |
1386471148 | 2017-09-08 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection. |
1393016224 | 2014-02-20 | Salt Water Injection Well | No Violations | On site to witness Blue Dot Wire line run tools in well to check total depth and try and determine if tubing or packer has failed integrity. |
1395356262 | 2014-03-20 | Salt Water Injection Well | No Violations | Inspection revealed that Key Energy Services has a coil tubing unit on well trying to clean out fill up in bottom of hole and once cleaned out they will hire service rig to release packer and pull from well to check for leakage in tubing or packer. |
1405716944 | 2014-07-18 | Salt Water Injection Well | No Violations | On site to pressure test annulus of tubing and to witness mini frack operation on said well. |
1476908876 | 2016-10-14 | Salt Water Injection Well | No Violations | Inspection revealed that well is not in operation at this time ,owner is planning on plugging well back at some point in time. |
1481224978 | 2016-12-06 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump to this well was not in operation at the time of my inspection. |
1494808018 | 2019-03-25 | Salt Water Injection Well | No Violations | On site to meet with contractors to discuss upcoming plug back operation. |
1524852011 | 2018-04-26 | Salt Water Injection Well | No Violations | Inspection today indicated that well was not in operation during my inspection. |
1532204319 | 2018-07-19 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
|
1542838378 | 2013-10-16 | Salt Water Injection Well | No Violations | Inspection revealed that well was in operation today and it was noted that company owned vacuum trucks were emptying storage tanks at the site of approved temporary storage facility. |
1550706580 | 2014-06-24 | Salt Water Injection Well | No Violations | Inspection revealed that service rig was still on site preparing to run tubing back into well and wash to bottom and once they have bottom of hole cleaned up they plan on running scraper in well and then place liner string in place. |
1570045644 | 2019-9-30 0:00: | PB | No Violations | |
1571250546 | 2019-10-12 0:00 | PB | No Violations | 6.00 |
1571648235 | 2019-10-18 0:00 | PB | No Violations | |
1572443736 | 2019-10-28 0:00 | PB | No Violations | |
1572628103 | 2019-10-29 0:00 | PB | No Violations | |
1573594892 | 2019-11-12 0:00 | PB | No Violations | |
1573672769 | 2019-11-12 0:00 | PB | No Violations | |
1574445293 | 2019-11-16 0:00 | PB | No Violations | 8.00 |
1576255733 | 2019-12-8 0:00: | PB | No Violations | 4.00 |
1576269627 | 2019-12-11 0:00 | PB | No Violations | |
1576520340 | 2019-12-15 0:00 | PB | No Violations | 6.00 |
1576861392 | 2019-12-17 0:00 | PB | No Violations | |
1576867046 | 2019-12-18 0:00 | PB | No Violations | |
1577528803 | 2019-12-24 0:00 | PB | No Violations | |
1630193220 | 2019-10-23 0:00 | SW | No Violations | |
1638383744 | 2013-12-02 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that temporary storage site has been decommissioned. |
1687696078 | 2016-06-06 | Salt Water Injection Well | No Violations | Well not in operation during my inspection. |
1727551462 | 2013-02-15 | Salt Water Injection Well | No Violations | On site for pre spud meeting with drilling contractor personnel and company reps to discuss drilling procedure and safety issues and answer questions regarding state regulations pertaining to drilling SWIW in Ohio. |
1782742291 | 2019-11-15 0:00 | PB | No Violations | |
178828093 | 2017-2-1 0:00:0 | SW | No Violations | |
1833413072 | 2017-04-05 | Salt Water Injection Well | No Violations | Inspection revealed that pump was not in operation during our inspection. |
1836284607 | 2013-12-13 | Salt Water Injection Well | No Violations | Inspection revealed that well is not in operation at this time. |
1861031987 | 2016-03-01 | Salt Water Injection Well | No Violations | Unable to check pressures today due to locks being changed out at the well head, called company and requested key so I can get required pressure readings. |
1882999581 | 2014-06-17 | Salt Water Injection Well | No Violations | Inspection revealed that service rig on site mixing drill mud to kill said well and once killed they will release packer and pull from well and then they plan on running liner string into open hole section of well bore. |
1890958709 | 2013-02-20 | Salt Water Injection Well | No Violations | On site to witness testing of Blowout Prevent or, Greenes Energy Group tested blind rams at 250 psi on low side and 2500 psi on high side with no decline in pressures and also tested annular section with 250 psi on low side and 1500 psi on high side with no pressure loss and kill lines were tested and choke manifold was also tested and pipe rams also passed testing levels approved by inspector. |
1927237123 | 2019-10-9 0:00: | PB | No Violations | |
1936958455 | 2018-11-21 | Salt Water Injection Well | No Violations | Inspection revealed that well was not in operation during my inspection. |
194000599 | 2018-1-9 0:00:0 | SW | No Violations | |
1974930350 | 2015-03-18 | Salt Water Injection Well | No Violations | On site to witness mini test on annulus of injection string they pressured up to 680 psi and we monitored pressure for 15 minutes with no decline in pressure and it appears that well is not used much at this time due to high pressure issues. |
2000905025 | 2020-4-20 0:00: | SW | No Violations | |
2061546145 | 2014-01-28 | Salt Water Injection Well | No Violations | Inspection revealed that well is down waiting on company to deepen well or possibly plug due to fact that current injection zone wont take fluid. |
2095607429 | 2014-07-22 | Preliminary Restoration | No Violations | Inspection revealed that site has been restored and well is back into active disposal mode. |
2113170097 | 2013-12-30 | Salt Water Injection Well | No Violations | Inspection revealed that well is not in use at this time due to high injection pressures, owner is considering applying for deepening permit at this time. |
2134671361 | 2014-12-11 | Salt Water Injection Well | No Violations | Inspection revealed that well was not in operation during my inspection and it was noted that owner has winterized wellhead and associated plumbing going to well. |
269218046 | 2014-6-16 0:00: | SW | No Violations | |
368935874 | 2013-3-1 0:00:0 | SW | No Violations | |
566448239 | 2019-12-19 0:00 | PB | No Violations | |
74355347 | 2013-8-21 0:00: | SW | No Violations | 2.00 |
747030739 | 2014-6-26 0:00: | SW | No Violations | |
766412508 | 2013-2-22 0:00: | SW | No Violations | |
767143750 | 2019-2-28 0:00: | SW | No Violations | |
807598334 | 2018-5-27 0:00: | SW | No Violations | |
904552061 | 2013-8-21 0:00: | SW | No Violations | 2.50 |
93698858 | 2019-12-27 0:00 | PB | No Violations | |
96115455 | 2013-11-20 0:00 | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1185538084 | US-OH-104905 | 2018-03-21 | NONE | Failure to report disposal fees |
For data sources see[5]