If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-167-60414 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.61,"lon":-81.41,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Washington | |
Municipality: Aurelius Township | |
Operator Name: TRIAD HUNTER LLC | |
Well Pad ID: | |
Farm/Lease Name: TORPY MILLS (J L MILLS) | |
License Status: Final Restoration | |
License Date: 2018-10-24 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 39.610000 | |
Longitude: -81.410000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Change of Owner | 2003-09-12 | Operator changed from 2060, FEICK C R to 7517, PIERSOL OIL AND GAS |
Change of Owner | 2006-03-20 | Operator changed from 7517, PIERSOL OIL AND GAS to 2348, TRIAD RESOURCES INC |
Change of Owner | 2010-03-24 | Operator changed from 2348, TRIAD RESOURCES INC to 8610, TRIAD HUNTER LLC |
APP | 2018-10-24 | Proposed Formations:BEREA SAND, Issued Date:10/24/2018, Expired Date:10/23/2020 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2018-11-07 | UPDATE LOCATION PER DOGRM SURVEYOR ALE 10/29/2018. GMM UPDATED PLUG STATUS |
Record Last Modified | 2019-04-26 | UPDATE LOCATION PER DOGRM SURVEYOR ALE 10/29/2018. GMM UPDATED PLUG STATUS |
Construction Permit Expires | 2020-10-23 | UPDATE LOCATION PER DOGRM SURVEYOR ALE 10/29/2018. GMM UPDATED PLUG STATUS |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1998 | FEICK C R | 0.00 | 135.00 | 365 |
1999 | FEICK C R | 0.00 | 134.00 | 365 |
2000 | FEICK C R | 0.00 | 135.00 | 365 |
2001 | FEICK C R | 0.00 | 136.00 | 365 |
2002 | FEICK C R | 0.00 | 131.00 | 365 |
2003 | FEICK C R | 0.00 | 319.00 | 365 |
2004 | PIERSOL OIL AND GAS | 0.00 | 26.00 | 365 |
2005 | PIERSOL OIL AND GAS | 0.00 | 25.00 | 365 |
2006 | TRIAD RESOURCES INC | 0.00 | 47.00 | 365 |
2007 | TRIAD RESOURCES INC | 0.00 | 53.00 | 365 |
2008 | TRIAD RESOURCES INC | 0.00 | 37.00 | 365 |
2009 | TRIAD RESOURCES INC | 0.00 | 0.00 | 365 |
2010 | TRIAD RESOURCES INC | 0.00 | 0.00 | 365 |
2011 | TRIAD HUNTER LLC | 0.00 | 0.00 | 365 |
2012 | TRIAD HUNTER LLC | 0.00 | 0.00 | 366 |
2013 | TRIAD HUNTER LLC | 0.00 | 0.00 | 365 |
2014 | TRIAD HUNTER LLC | 0.00 | 0.00 | 0 |
2015 | TRIAD HUNTER LLC | 0.00 | 0.00 | 0 |
2016 | TRIAD HUNTER LLC | 0.00 | 0.00 | 0 |
2017 | TRIAD HUNTER LLC | 0.00 | 197.00 | 365 |
2018 | TRIAD HUNTER LLC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1998 | FEICK C R | Brine | 0 | 365 |
1999 | FEICK C R | Brine | 0 | 365 |
2000 | FEICK C R | Brine | 0 | 365 |
2001 | FEICK C R | Brine | 0 | 365 |
2002 | FEICK C R | Brine | 0 | 365 |
2003 | FEICK C R | Brine | 0 | 365 |
2004 | PIERSOL OIL AND GAS | Brine | 0 | 365 |
2005 | PIERSOL OIL AND GAS | Brine | 0 | 365 |
2006 | TRIAD RESOURCES INC | Brine | 0 | 365 |
2007 | TRIAD RESOURCES INC | Brine | 0 | 365 |
2008 | TRIAD RESOURCES INC | Brine | 0 | 365 |
2009 | TRIAD RESOURCES INC | Brine | 0 | 365 |
2010 | TRIAD RESOURCES INC | Brine | 0 | 365 |
2011 | TRIAD HUNTER LLC | Brine | 0 | 365 |
2012 | TRIAD HUNTER LLC | Brine | 0 | 366 |
2013 | TRIAD HUNTER LLC | Brine | 0 | 365 |
2014 | TRIAD HUNTER LLC | Brine | 0 | 0 |
2015 | TRIAD HUNTER LLC | Brine | 0 | 0 |
2016 | TRIAD HUNTER LLC | Brine | 0 | 0 |
2017 | TRIAD HUNTER LLC | Brine | 0 | 365 |
2018 | TRIAD HUNTER LLC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1354762653 | 2016-2-26 0:00: | PW | No Violations | 0.50 |
-615538018 | 2016-3-30 0:00: | AM | No Violations | 0.20 |
-905720597 | 2018-11-6 0:00: | PB | No Violations | 8.00 |
-938159044 | 2016-11-3 0:00: | PW | No Violations | 0.10 |
0544320526 | 2018-10-31 | Plug / Plug Back | No Violations | I was on location today to witness the plugging of this well. Blue Ridge has Viking Well Service on this well to plug it. They have already pulled the rods and tubing from the well. Today they are running 2 inch diameter tubing back in the well and having Formation Cementing come out to plug the well. Formation Cementing ended up not being able to make it because of another job. We had to shut down for the day. |
0615538018 | 2016-03-30 | Administrative Inspection | No Violations | Met at Barlow Office with Supervisor Dan Goins and Triad-Hunter representatives Ben Smeltzer and Bob Handschumaker to discuss compliance issues at this well. Triad-Hunter is in the process of evaluating this well for potential to produce or if it needs plugged and abandoned. |
0905720597 | 2018-11-06 | Plug / Plug Back | No Violations | I was on location today to witness the plugging of this well. Today the rig crew had Formation Cementing come out to plug this well. The well only has 5.5 inch diameter casing in it. The rig crew ran 1692 feet of 2 inch diameter tubing in the well. They set a 400 foot plug with Class a cement then pulled the tubing up to 300 feet. We then pumped 25 sacks of Class a cement at this point. The tubing was then pulled from the well and a bridge plug was set at 200 feet. The cement did not stay at the surface so we shut down to let the cement setup. |
0938159044 | 2016-11-03 | Production Wells | No Violations | ODNR Division of Oil and Gas supervisors Dan Goins and Eric Conrad, and I met with Triad Hunter representatives Austin Clark, Mike Horan, and Bob Handschumaker. We discussed the violation issues with this well and a timeline in which these violations shall be put back within compliance. Triad stated that they plan to plug this well. |
0976309314 | 2019-04-23 | Final Restoration | No Violations | I was on location today to do the final restoration on this well. The final restoration meets 1509.072(B) requirements. |
0980852222 | 2018-11-07 | Plug / Plug Back | No Violations | I was back on location today to witness the plugging of this well. Today Formation Cementing was back on location to top off the well. The cement had settled out to 141 feet. The rig crew ran tubing down over the hill to the well so Formation could pump cement to the well. The cement stayed at the surface with no air pockets. The well is now plugged. |
1250566140 | 2009-04-24 | Production Wells | No Violations | Inspection this day found well with rods, tubing, 1 gas escape packer but no jack, no tank, no IDs. Lots of old steel lines, fittings around the location. Well not producing. Needs NOV. |
1354762653 | 2016-02-26 | Production Wells | Violations Noted | Upon inspection, it was observed that this well is capable of production, but is currently shut-in and is idle. The well consists of a pumping unit standing over 5.1875 casing, 2.375 production tubing with rods, and 1 tubing on a gas escape packer. Judging by the deteriorating surface equipment and overgrowth of vegetation, it is assumed that the well has not operated in a significant amount of time. There is no flow line attached to the 1 gas escape tubing. There is a 100 bbl production tank nearby which has ID information from Triad and refers to the well as P#60414, which is correct. RBDMS records indicate that no production has ever been reported for the well. The well shall be plugged and abandoned. Triad Hunter LLC shall submit a written plugging schedule within 30 days to Inspector Lynn Parkins at 5880 Memory Rd. Zanesville, OH 43701 and plug the well within 180 days. Triad Hunter LLC will be notified if the plugging schedule is approved or denied. |
544320526 | 2018-10-31 0:00 | PB | No Violations | 8.00 |
976309314 | 2019-4-23 0:00: | FR | No Violations | 0.70 |
980852222 | 2018-11-7 0:00: | PB | No Violations | 8.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1354762653 | US-OH-110261 | 2016-03-07 | Well shall be plugged |
For data sources see[7]