If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-167-65895 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.44,"lon":-81.13,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: PD VALENTINE OIL & GAS LLC | |
Well Pad ID: | |
Farm/Lease Name: HOLDREN | |
License Status: Producing | |
License Date: 2000-01-20 | |
Spud Date: 1900-01-01 | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 39.440000 | |
Longitude: -81.130000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Change of Owner | 2000-05-08 | Operator changed from 5426, BEAVER WALTER & ROMENA to 6151, VALENTINE OIL CO P & D |
Change of Owner | 2018-12-19 | Operator changed from 6151, P & D VALENTINE OIL CO to 10284, P D VALENTINE OIL & GAS LLC |
Record Last Modified | 2018-12-19 | P# ASSIGNED 1/20/2000. NO PREVIOUS RECORD OF WELL. |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | P & D VALENTINE OIL CO | 200.00 | 25.00 | 365 |
2001 | P & D VALENTINE OIL CO | 57.00 | 39.00 | 365 |
2002 | P & D VALENTINE OIL CO | 0.00 | 80.00 | 365 |
2005 | P & D VALENTINE OIL CO | 140.00 | 15.00 | 365 |
2006 | P & D VALENTINE OIL CO | 250.00 | 0.00 | 365 |
2007 | P & D VALENTINE OIL CO | 354.00 | 27.00 | 365 |
2008 | P & D VALENTINE OIL CO | 50.00 | 50.00 | 365 |
2009 | P & D VALENTINE OIL CO | 80.00 | 50.00 | 365 |
2011 | P & D VALENTINE OIL CO | 90.00 | 25.00 | 365 |
2012 | P & D VALENTINE OIL CO | 300.00 | 70.00 | 366 |
2013 | P & D VALENTINE OIL CO | 325.00 | 75.00 | 365 |
2014 | P & D VALENTINE OIL CO | 325.00 | 26.00 | 365 |
2015 | P & D VALENTINE OIL CO | 338.00 | 0.00 | 365 |
2016 | P & D VALENTINE OIL CO | 653.00 | 12.00 | 366 |
2017 | P & D VALENTINE OIL CO | 464.00 | 4.00 | 365 |
2018 | P & D VALENTINE OIL CO | 368.00 | 19.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2001 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2002 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2005 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2006 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2007 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2008 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2009 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2011 | P & D VALENTINE OIL CO | Brine | 31 | 365 |
2012 | P & D VALENTINE OIL CO | Brine | 55 | 366 |
2013 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2014 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2015 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
2016 | P & D VALENTINE OIL CO | Brine | 0 | 366 |
2017 | P & D VALENTINE OIL CO | Brine | 32 | 365 |
2018 | P & D VALENTINE OIL CO | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1324540869 | 2018-4-10 0:00: | PW | No Violations | 1.00 |
-1344718062 | 2011-5-31 0:00: | PW | No Violations | 1.50 |
-1649884723 | 2016-7-18 0:00: | PW | No Violations | 1.00 |
-1967088447 | 2018-8-21 0:00: | PW | No Violations | 0.60 |
-565857821 | 2017-5-25 0:00: | PW | No Violations | 1.00 |
0018688062 | 2011-06-17 | Production Wells | No Violations | Inspection this day found IDs now up, fence around both well and tank, producing. RESOLVED |
0565857821 | 2017-05-25 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with a pumping unit, a 7 inch diameter wellhead and 1 1/2 inch diameter production tubing. The valves on the wellhead are open at the time of inspection. The pumping unit is surrounded by a privacy fence. The tank battery is equipped with a vertical separator, a compressor unit, and an 100 barrel steel tank. The compressor was running at the time of inspection. The tank battery for the well is also surrounded by a privacy fence. There are no issues to report at this time and the well is in production at the time of inspection. |
0700944853 | 2005-02-11 | Production Wells | No Violations | Inspection this day found well with jack producing, tank has good IDs, needs more dike |
1324540869 | 2018-04-10 | Production Wells | Violations Noted | I received a call from Jim Woods of BLM about this well. Jim informed me that there were areas inside the tank battery and around the wellhead that looked like oil had been spilled. The inspection this day revealed that this well is equipped with a pumping unit, 4 1/2 inch diameter production casing, and production tubing. Around the wellhead there was a material that looked like saw dust to absorb the oil that was on the ground. The soil around the wellhead looked to have absorbed the oil and when it was touched you could feel that oil was soaked into it. The tank battery for this well is equipped with a 100 barrel steel tank, a separator, and a small motor that is used as a compressor station for the well. There is no proper identification on the tank battery or the wellhead. I spoke with Paul Valentine owner of P&D Valentine and iformed him he must take the proper steps to remediated the soil near the wellhead and inside the tank battery. I also informed him he must post proper and legible identification on the wellhead or tank. |
1344718062 | 2011-05-31 | Production Wells | Violations Noted | Inspection this day requested by Forest Service - feel there are violations. Reports that operator is dumping his brine water but not found this day. Well found producing with jack, capable, valves open, small compressor at tank running. Tank has good dike, trash, old oil jugs, and old electric box on pole laying inside dike, small hole inside dike but water in it tests fresh. IDs need operator name, permit no listed. Possibly there was a commitment of tank and well fenced and that has not been done. Would be a very good idea to fence both. 6/17 - All requirements met - IDs up as is fence. RESOLVED |
1563201891 | 2019-7-15 0:00: | PW | No Violations | 0.50 |
1649884723 | 2016-07-18 | Production Wells | No Violations | My inspection today found that the well is equipped with 7 inch casing on a hanger, 2 inch tubing, rods, and a pumping unit. The well is in production, producing out of the 7 inch casing, and the 2 inch tubing. The well and pumping unit are within a wooden privacy fence. The production equipment consist of one 100 barrel tank, a vertical separator, a drip, and a small electric powered gas compressor. The production equipment is within an earthen dike and a privacy fence. Identification is located on the 100 barrel tank. There are no violations during my inspection. Well and tank battery are located alongside the paved road leading to the Wayne National Forest Frontier Boat Launch. |
18688062 | 2011-6-17 0:00: | PW | No Violations | 0.50 |
1927628320 | 2019-06-03 | Production Wells | Violations Noted | On this day, I am conducting an inspection in regard to a notification of potential pollution and contamination at the production facility. I found the well to be produced by means of a pumping unit with rods and tubing, and the production valves appear to be open. The unit is contained within a locked wooden fence, limiting access to the wellhead. The production facility consists of (1) 100-barrel steel tank, drip tank, vertical separator, and a gas compressor all contained within an earthen dike that is fenced and locked, also limiting the access. Pictures were taken over the fence revealing product on the ground and stressed vegetation where the product had been released within the dike. A shovel and absorbent pads are currently present. The affected area will need to be addressed, and any additional product will need to be removed and disposed of properly. On 6/3/2019, I attempted to contact Mr. Paul Valentine and left a voicemail requesting a callback. |
1967088447 | 2018-08-21 | Production Wells | No Violations | On this day, I am conducting a compliance notice follow-up inspection. I found the issues to be resolved from 04/10/2018. |
700944853 | 2005-2-11 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1324540869 | US-OH-109285 | 2018-04-17 | 9-1-07 | Well operation causing pollution and contamination |
1324540869 | US-OH-109286 | 2018-04-17 | 9-9-05(A)10 | Failure to legibly identify well |
1344718062 | US-OH-109967 | 2011-05-31 | General Safety | |
1344718062 | US-OH-109968 | 2011-05-31 | Failure to legibly identify well | |
1927628320 | US-OH-119405 | 2019-06-11 | 9-1-07 | Well operation causing pollution and contamination |
For data sources see[7]