If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-21314 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.89,"lon":-81.9,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Wayne Township | |
Operator Name: D & D ENERGY COMPANY | |
Well Pad ID: | |
Farm/Lease Name: YATES HARRY | |
License Status: Producing | |
License Date: 1962-08-10 | |
Spud Date: 1962-08-07 | |
Spud Drilling Contractor: | |
Final Drill Date: 1962-08-30 | |
Well Total Depth: 5725.00 ft | |
Configuration: Vertical | |
Latitude: 40.890000 | |
Longitude: -81.900000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1962-08-07 | |
Completed | 1962-08-30 | |
Reached Total Depth | 1962-08-30 | |
Completion Report Received | 1962-10-09 | |
Plugged Back | 1965-08-10 | |
CO | 1988-02-05 | 265 CSAPO FRANK A JR |
Change of Owner | 2013-01-07 | Operator changed from 265, CSAPO LIMITED to 8423, C & C PRODUCING LLC |
Change of Owner | 2016-11-14 | Operator changed from 8423, C & C PRODUCING LLC to 5569, D & D ENERGY COMPANY |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1998-03-25 | 3431 | 3452 | 0 |
3431 | 3452 | 0 | |
5640 | 5656 | 89 | |
1998-03-25 | 5640 | 5656 | 89 |
3431 | 3452 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
OIL | 0 | 600 Bbl | 12500 | WELL GAUGED 848MCF AFTER FRAC |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | OBERMILLER CLARENCE TRUST | 0.00 | 75.00 | 0 |
1985 | OBERMILLER CLARENCE TRUST | 0.00 | 159.00 | 365 |
1986 | OBERMILLER CLARENCE TRUST | 0.00 | 79.00 | 365 |
1987 | OBERMILLER CLARENCE TRUST | 0.00 | 79.00 | 365 |
1988 | CSAPO LIMITED | 0.00 | 81.00 | 365 |
1989 | CSAPO LIMITED | 0.00 | 0.00 | 365 |
1990 | CSAPO LIMITED | 0.00 | 163.00 | 365 |
1991 | CSAPO LIMITED | 0.00 | 81.00 | 365 |
1992 | CSAPO LIMITED | 0.00 | 0.00 | 0 |
1993 | CSAPO LIMITED | 0.00 | 84.00 | 365 |
1994 | CSAPO LIMITED | 0.00 | 86.00 | 365 |
1995 | CSAPO LIMITED | 0.00 | 82.00 | 365 |
1996 | CSAPO LIMITED | 0.00 | 0.00 | 365 |
1997 | CSAPO LIMITED | 0.00 | 82.00 | 365 |
1998 | CSAPO LIMITED | 0.00 | 86.00 | 365 |
2000 | CSAPO LIMITED | 0.00 | 81.00 | 365 |
2001 | CSAPO LIMITED | 0.00 | 0.00 | 365 |
2002 | CSAPO LIMITED | 0.00 | 82.00 | 365 |
2003 | CSAPO LIMITED | 0.00 | 0.00 | 365 |
2004 | CSAPO LIMITED | 0.00 | 68.00 | 365 |
2005 | CSAPO LIMITED | 0.00 | 0.00 | 365 |
2006 | CSAPO LIMITED | 0.00 | 83.00 | 365 |
2007 | CSAPO LIMITED | 0.00 | 32.00 | 365 |
2008 | CSAPO LIMITED | 0.00 | 35.00 | 365 |
2009 | CSAPO LIMITED | 0.00 | 68.00 | 365 |
2010 | CSAPO LIMITED | 0.00 | 0.00 | 0 |
2011 | CSAPO LIMITED | 0.00 | 51.00 | 365 |
2012 | CSAPO LIMITED | 0.00 | 59.00 | 366 |
2013 | C & C PRODUCING LLC | 0.00 | 40.00 | 365 |
2014 | C & C PRODUCING LLC | 0.00 | 42.00 | 365 |
2015 | C & C PRODUCING LLC | 0.00 | 37.00 | 365 |
2016 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
2017 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
2018 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | OBERMILLER CLARENCE TRUST | Brine | 0 | 0 |
1985 | OBERMILLER CLARENCE TRUST | Brine | 0 | 365 |
1986 | OBERMILLER CLARENCE TRUST | Brine | 0 | 365 |
1987 | OBERMILLER CLARENCE TRUST | Brine | 0 | 365 |
1988 | CSAPO LIMITED | Brine | 0 | 365 |
1989 | CSAPO LIMITED | Brine | 0 | 365 |
1990 | CSAPO LIMITED | Brine | 0 | 365 |
1991 | CSAPO LIMITED | Brine | 0 | 365 |
1992 | CSAPO LIMITED | Brine | 0 | 0 |
1993 | CSAPO LIMITED | Brine | 0 | 365 |
1994 | CSAPO LIMITED | Brine | 3 | 365 |
1995 | CSAPO LIMITED | Brine | 0 | 365 |
1996 | CSAPO LIMITED | Brine | 0 | 365 |
1997 | CSAPO LIMITED | Brine | 0 | 365 |
1998 | CSAPO LIMITED | Brine | 0 | 365 |
2000 | CSAPO LIMITED | Brine | 1 | 365 |
2001 | CSAPO LIMITED | Brine | 0 | 365 |
2002 | CSAPO LIMITED | Brine | 0 | 365 |
2003 | CSAPO LIMITED | Brine | 0 | 365 |
2004 | CSAPO LIMITED | Brine | 0 | 365 |
2005 | CSAPO LIMITED | Brine | 0 | 365 |
2006 | CSAPO LIMITED | Brine | 0 | 365 |
2007 | CSAPO LIMITED | Brine | 2 | 365 |
2008 | CSAPO LIMITED | Brine | 0 | 365 |
2009 | CSAPO LIMITED | Brine | 0 | 365 |
2010 | CSAPO LIMITED | Brine | 0 | 0 |
2011 | CSAPO LIMITED | Brine | 0 | 365 |
2012 | CSAPO LIMITED | Brine | 0 | 366 |
2013 | C & C PRODUCING LLC | Brine | 0 | 365 |
2014 | C & C PRODUCING LLC | Brine | 0 | 365 |
2015 | C & C PRODUCING LLC | Brine | 0 | 365 |
2016 | C & C PRODUCING LLC | Brine | 0 | 365 |
2017 | D & D ENERGY COMPANY | Brine | 0 | 0 |
2018 | D & D ENERGY COMPANY | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1278981177 | 2017-8-5 0:00:0 | PW | No Violations | |
-1658892163 | 2016-12-28 0:00 | PW | No Violations | |
0515518713 | 2018-05-30 | Production Wells | No Violations | Inspected production well on 05/30/2018. The tank battery consists of 1-100 bbl steel tank, located within an earthen dike; 1-vertical separator and 2-Aspire stations are located nearby. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |
1278981177 | 2017-08-05 | Production Wells | No Violations | Inspected production well on 08/05/2017. The tank battery consists of 1-100 bbl steel tank, located within an earthen dike; 1-vertical separator is located nearby. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |
1658892163 | 2016-12-28 | Production Wells | No Violations | Inspected production well on 12/28/2016. The tank battery consists of 1-100 bbl steel tank, located within an earthen dike; 1-vertical separator is located nearby. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |
1754495540 | 2020-8-20 0:00: | PW | No Violations | |
515518713 | 2018-5-30 0:00: | PW | No Violations |
For data sources see[9]