Well ID: 34-169-22683
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Clinton Township
Operator Name: CAPSTONE OIL PRODUCING LLC
Well Pad ID:
Farm/Lease Name: WELLS
License Status: Producing
License Date: 1980-12-31
Spud Date: 1981-05-05
Spud Drilling Contractor:
Final Drill Date: 1981-05-09
Well Total Depth: 3299.00 ft
Configuration: Vertical
Latitude: 40.700000
Longitude: -82.020000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-12-31 2960 TUCO PARTNERSHIP GeoDate 12/31/80
Oil and Gas 1980-12-31 Issued Date 12/31/80 Expired Date Acres 0020000 Tool Type CRAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1981-05-05
Completed 1981-05-09
Reached Total Depth 1981-05-09
CO 1992-01-02 627 KENOIL GeoDate 12/31/80
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3157 3174 18
3157 3174 18
3157 3174 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 4500

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DERBY OIL & GAS CORP 10512.00 2062.00 0
1985 DERBY OIL & GAS CORP 6622.00 828.00 335
1986 DERBY OIL & GAS CORP 3411.00 373.00 267
1992 KENOIL LLC 1373.00 367.00 365
1993 KENOIL LLC 1199.00 230.00 365
1994 KENOIL LLC 1172.00 153.00 0
1995 KENOIL LLC 1169.00 153.00 0
1996 KENOIL LLC 1367.00 149.00 0
1997 KENOIL LLC 810.00 210.00 365
1998 KENOIL LLC 867.00 139.00 365
1999 KENOIL LLC 683.00 75.00 0
2000 KENOIL LLC 627.00 141.00 365
2001 KENOIL LLC 892.00 78.00 365
2002 KENOIL LLC 526.00 77.00 365
2003 KENOIL LLC 634.00 147.00 365
2004 KENOIL LLC 748.00 150.00 365
2005 KENOIL LLC 639.00 135.00 365
2006 KENOIL LLC 559.00 71.00 365
2007 KENOIL LLC 554.00 66.00 365
2008 KENOIL LLC 555.00 70.00 365
2009 KENOIL LLC 645.00 70.00 365
2010 KENOIL LLC 592.00 66.00 365
2011 KENOIL LLC 521.00 0.00 0
2012 KENOIL LLC 541.00 71.00 366
2013 KENOIL LLC 448.00 116.00 365
2014 KENOIL LLC 387.00 75.00 365
2015 KENOIL LLC 421.00 75.00 365
2016 KENOIL LLC 509.00 67.00 365
2017 KENOIL LLC 458.00 119.00 365
2018 KENOIL LLC 305.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DERBY OIL & GAS CORP Brine 15 0
1985 DERBY OIL & GAS CORP Brine 192 335
1986 DERBY OIL & GAS CORP Brine 138 267
1992 KENOIL LLC Brine 0 365
1993 KENOIL LLC Brine 0 365
1994 KENOIL LLC Brine 0 0
1995 KENOIL LLC Brine 0 0
1996 KENOIL LLC Brine 0 0
1997 KENOIL LLC Brine 0 365
1998 KENOIL LLC Brine 0 365
1999 KENOIL LLC Brine 35
2000 KENOIL LLC Brine 0 365
2001 KENOIL LLC Brine 0 365
2002 KENOIL LLC Brine 0 365
2003 KENOIL LLC Brine 0 365
2004 KENOIL LLC Brine 0 365
2005 KENOIL LLC Brine 0 365
2006 KENOIL LLC Brine 0 365
2007 KENOIL LLC Brine 0 365
2008 KENOIL LLC Brine 0 365
2009 KENOIL LLC Brine 0 365
2010 KENOIL LLC Brine 0 365
2011 KENOIL LLC Brine 20
2012 KENOIL LLC Brine 0 366
2013 KENOIL LLC Brine 0 365
2014 KENOIL LLC Brine 0 365
2015 KENOIL LLC Brine 0 365
2016 KENOIL LLC Brine 0 365
2017 KENOIL LLC Brine 20 365
2018 KENOIL LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1189017874 2016-3-30 0:00: PW No Violations
-185666199 2018-9-12 0:00: PW No Violations
0185666199 2018-09-12 Production Wells No Violations Inspected production well on 09/12/2018. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike; the diked area is shared with the tank battery for the Wells #1 well (PN: 169-22247). Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. The well is located ~165 from its RBDMS location. A comparison of the well location with the original plat indicated that the permit number is correct, only the location is incorrect. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Gregg Miller and Aaron Lantz (DOGRM Columbus). No other problems were noted at the time of the inspection.
0912563817 2017-07-27 Production Wells No Violations Inspected production well on 07/27/2017. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike; the diked area is shared with the tank battery for the Wells #1 well (PN: 169-22683). Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The well is located ~160 from its RBDMS location. No problems were noted at the time of the inspection.
1189017874 2016-03-30 Production Wells No Violations Inspected production well on 03/30/2016. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
1309883347 2020-4-21 0:00: PW No Violations
912563817 2017-7-27 0:00: PW No Violations

For data sources see[9]