34-169-23345

Well Details

Well ID: 34-169-23345
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Chester Township
Operator Name: SCHWARTZ CHRIS AND PAUL
Well Pad ID:
Farm/Lease Name: BOREMAN
License Status: Domestic Well
License Date: 2007-04-09
Spud Date: 1982-07-12
Spud Drilling Contractor: LEE MORAVY
Final Drill Date: 1982-08-21
Well Total Depth: 3174.00 ft
Configuration: Vertical
Latitude: 40.870000
Longitude: -82.020000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-07-02 Issued Date 7/2/82 Expired Date 1/1/83 Acres 0074000 Tool Type CT Proposed Formation CLINTON Proposed Depth 03174 Proposed Drill Depth 03174
Original Spud 1982-07-12
Completed 1982-08-21
Reached Total Depth 1982-08-21
CO 1982-10-22 79 OXFORD OIL CO GeoDate 7/2/82
Completion Report Received 1982-10-26
CO 1986-02-10 79 OXFORD OIL CO GeoDate 2/10/86
Unknown 1986-02-10 Issued Date 2/10/86 Expired Date 2/10/87 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
CO 1986-11-14 2577 MONTANA PRODUCTS INC GeoDate 2/10/86
Change of Owner 1998-12-29 Operator changed from 2577, MONTANA PRODUCTS INC to 627, KENOIL
APP 2007-04-09 Proposed Formations:CLINTON, Issued Date:4/9/2007, Expired Date:4/8/2008 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2007-10-24 Operator changed from 627, KENOIL to 8249, SCHWARTZ CHRIS AND PAUL
Construction Permit Expires 2008-04-08
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3112 3116 5
2006-09-11 3118 3122 5
3112 3116 5
3112 3116 5
2006-09-11 3128 3134 7

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 3500 Bbl 25000 FRAC: 3500BBL H2O, 25M SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 OXFORD OIL 1614.00 82.00 0
1985 OXFORD OIL 576.00 64.00 365
1986 OXFORD OIL 254.00 33.00 365
1999 KENOIL LLC 742.00 71.00 0
2000 KENOIL LLC 338.00 61.00 365
2001 KENOIL LLC 284.00 0.00 365
2002 KENOIL LLC 295.00 0.00 365
2003 KENOIL LLC 415.00 0.00 365
2004 KENOIL LLC 280.00 0.00 365
2005 KENOIL LLC 421.00 0.00 365
2006 KENOIL LLC 187.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 OXFORD OIL Brine 0 0
1985 OXFORD OIL Brine 60 365
1986 OXFORD OIL Brine 0 365
1999 KENOIL LLC Brine 0
2000 KENOIL LLC Brine 365
2001 KENOIL LLC Brine 0 365
2002 KENOIL LLC Brine 0 365
2003 KENOIL LLC Brine 0 365
2004 KENOIL LLC Brine 0 365
2005 KENOIL LLC Brine 50 365
2006 KENOIL LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1432286559 2018-03-30 Production Wells No Violations Inspected domestic well on 03/30/2018 at the request of a neighboring landowner, Ms. Lisa Smith. Ms. Smith indicated that she had been receiving house gas from the well since she purchased the home from the well owners, but that the gas had been shut-off for several months due to lack of maintenance to the well. The tank battery consists of 1-100 bbl steel tank, located within an earthen dike; 1-meter with a drip and 2-regulators is located nearby. The well is equipped with a pump jack with an electric motor, drip, and meter box. Kenoil well identification is posted at both the tank battery and the wellhead. The gauges at the wellhead were broken, and the electric line through the woods to the wellhead is down. A slight crude oil odor was noted at the wellhead, but no leaks or spills were noted. After discussing the issue with Jennifer Barret (DOGRM Legal Staff), it was agreed that the well no longer qualifies for exempt domestic well status, and the owners must properly register the well and post bond. Will work with the well owners and DOGRM Legal and Surety departments to get the well properly registered. No other problems were noted at the time of the inspection.

For data sources see[9]

References