X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-23981

Well Details

Well ID: 34-169-23981
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Wayne Township
Operator Name: C & C PRODUCING LLC
Well Pad ID:
Farm/Lease Name: SMUCKER
License Status: Producing
License Date: 1984-11-14
Spud Date: 1984-12-14
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1984-12-16
Well Total Depth: 3477.00 ft
Configuration: Vertical
Latitude: 40.900000
Longitude: -81.910000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-11-14 Issued Date 11/14/84 Expired Date 5/13/85 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03477 Proposed Drill Depth 03477
Original Spud 1984-12-14
Completed 1984-12-16
Reached Total Depth 1984-12-16
CO 1984-12-21 360 RELIANCE ENERGY INC GeoDate 11/14/84
Completion Report Received 1985-01-15
Construction Permit Expires 1985-05-13
CO 1994-08-29 265 CSAPO FRANK A JR GeoDate 11/14/84
Change of Owner 2013-01-07 Operator changed from 265, CSAPO LIMITED to 8423, C & C PRODUCING LLC
Last Compliance Report 2014-08-05
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3408 3425 15
3408 3425 15
3408 3425 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 180 Mscf 0
H2O 0 65000 Gal 25000 FRAC: H2O,SAND,N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 RELIANCE ENERGY INC 0.00 1454.00 334
1986 RELIANCE ENERGY INC 6036.00 924.00 365
1987 RELIANCE ENERGY INC 2766.00 544.00 365
1988 RELIANCE ENERGY INC 2467.00 309.00 365
1989 RELIANCE ENERGY INC 1813.00 311.00 365
1990 RELIANCE ENERGY INC 1190.00 303.00 365
1991 RELIANCE ENERGY INC 962.00 158.00 365
1992 RELIANCE ENERGY INC 1010.00 239.00 365
1993 RELIANCE ENERGY INC 587.00 149.00 365
1994 RELIANCE ENERGY INC 447.00 87.00 227
1995 CSAPO LIMITED 0.00 316.00 365
1997 CSAPO LIMITED 0.00 308.00 365
1998 CSAPO LIMITED 0.00 0.00 365
2000 CSAPO LIMITED 0.00 0.00 365
2001 CSAPO LIMITED 0.00 157.00 365
2002 CSAPO LIMITED 0.00 152.00 365
2003 CSAPO LIMITED 0.00 0.00 365
2004 CSAPO LIMITED 0.00 149.00 365
2005 CSAPO LIMITED 0.00 0.00 365
2006 CSAPO LIMITED 0.00 119.00 365
2007 CSAPO LIMITED 30.00 78.00 365
2008 CSAPO LIMITED 521.00 218.00 365
2009 CSAPO LIMITED 392.00 155.00 365
2010 CSAPO LIMITED 424.00 146.00 365
2011 CSAPO LIMITED 356.00 77.00 365
2012 CSAPO LIMITED 558.00 135.00 366
2013 C & C PRODUCING LLC 417.00 119.00 365
2014 C & C PRODUCING LLC 562.00 177.00 365
2015 C & C PRODUCING LLC 372.00 130.00 365
2016 C & C PRODUCING LLC 464.00 144.00 365
2017 C & C PRODUCING LLC 374.00 76.00 365
2018 C & C PRODUCING LLC 341.00 111.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 RELIANCE ENERGY INC Brine 5 334
1986 RELIANCE ENERGY INC Brine 40 365
1987 RELIANCE ENERGY INC Brine 5 365
1988 RELIANCE ENERGY INC Brine 5 365
1989 RELIANCE ENERGY INC Brine 0 365
1990 RELIANCE ENERGY INC Brine 0 365
1991 RELIANCE ENERGY INC Brine 0 365
1992 RELIANCE ENERGY INC Brine 0 365
1993 RELIANCE ENERGY INC Brine 0 365
1994 RELIANCE ENERGY INC Brine 0 227
1995 CSAPO LIMITED Brine 0 365
1997 CSAPO LIMITED Brine 0 365
1998 CSAPO LIMITED Brine 0 365
2000 CSAPO LIMITED Brine 5 365
2001 CSAPO LIMITED Brine 0 365
2002 CSAPO LIMITED Brine 0 365
2003 CSAPO LIMITED Brine 0 365
2004 CSAPO LIMITED Brine 0 365
2005 CSAPO LIMITED Brine 0 365
2006 CSAPO LIMITED Brine 0 365
2007 CSAPO LIMITED Brine 5 365
2008 CSAPO LIMITED Brine 0 365
2009 CSAPO LIMITED Brine 0 365
2010 CSAPO LIMITED Brine 0 365
2011 CSAPO LIMITED Brine 30 365
2012 CSAPO LIMITED Brine 0 366
2013 C & C PRODUCING LLC Brine 26 365
2014 C & C PRODUCING LLC Brine 0 365
2015 C & C PRODUCING LLC Brine 0 365
2016 C & C PRODUCING LLC Brine 0 365
2017 C & C PRODUCING LLC Brine 0 365
2018 C & C PRODUCING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2134775602 2015-12-30 0:00 PW No Violations
00000PL581 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0161018420 2013-06-12 Production Wells No Violations This is a pump jack well. No apparent problems at this time.
1324343083 2015-08-24 Production Wells No Violations This is a pumping unit well. There are no apparent problems nor compliance issues at this time.
1402922332 2014-06-16 Production Wells No Violations This producing pumping unit well has no apparent problems at this time.
1534160694 2018-08-09 Production Wells No Violations Inspected production well on 08/09/2018. The tank battery consists of 2-100 bbl steel tanks, 2-vertical separators, 2-drips, and 2-meter boxes, located within an earthen dike. The well is equipped with a pump jack with an electric motor, and a compressor with 2-drips. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
161018420 2013-6-12 0:00: PW No Violations 0.50
170116055 2020-4-28 0:00: PW No Violations
2134775602 2015-12-30 Production Wells No Violations Inspected production well on 12/30/2015. The tank battery consists of 2-100 bbl steel tanks and 2-vertical separators located within an earthen dike. The well is equipped with a pump jack with an electric motor and a compressor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
2136172349 2017-09-20 Production Wells No Violations Inspected production well on 09/20/2017. The tank battery consists of 2-100 bbl steel tanks, 2-vertical separator, 2-drips, and 2-meter boxes, located within an earthen dike. The well is equipped with a pump jack with an electric motor, a drip, and compressor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
PL581 PL No Violations

For data sources see[9]