If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-24216 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.89,"lon":-81.95,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Wayne Township | |
Operator Name: MS PRODUCING LLC | |
Well Pad ID: | |
Farm/Lease Name: LYNDY ENTERPRISES | |
License Status: Producing | |
License Date: 1985-08-29 | |
Spud Date: 1985-08-27 | |
Spud Drilling Contractor: CO TOOLS | |
Final Drill Date: 1985-10-18 | |
Well Total Depth: 3420.00 ft | |
Configuration: Vertical | |
Latitude: 40.890000 | |
Longitude: -81.950000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1985-08-27 | |
CO | 1985-08-29 | 2023 H & H PRODUCING GeoDate 8/29/85 |
Oil and Gas | 1985-08-29 | Issued Date 8/29/85 Expired Date 8/29/86 Acres 0020000 Tool Type CT Proposed Formation CLINTON Proposed Depth 03420 Proposed Drill Depth 03420 |
Completed | 1985-10-18 | |
Reached Total Depth | 1985-10-18 | |
Completion Report Received | 1985-11-14 | |
Construction Permit Expires | 1986-08-29 | |
CO | 1994-10-26 | 3367 CRISSINGER ROBERT A INC GeoDate 8/29/85 |
Change of Owner | 1998-08-11 | Operator changed from 3367, CRISSINGER ROBERT A INC to 4356, JD PRODUCING INC |
Change of Owner | 2013-06-13 | Operator changed from 4356, JD PRODUCING INC to 5660, S & S ENERGY CORPORATION |
Change of Owner | 2017-01-12 | Operator changed from 5660, S & S ENERGY CORPORATION to 9842, MS PRODUCING LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3311 | 3364 | 19 |
3311 | 3364 | 19 | |
3311 | 3364 | 19 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 400 Gal | 0 | FRAC;H2O,N2 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1990 | CRISSINGER ROBERT A INC | 2710.00 | 0.00 | 182 |
1991 | CRISSINGER ROBERT A INC | 4227.00 | 0.00 | 365 |
1992 | CRISSINGER ROBERT A INC | 3571.00 | 0.00 | 365 |
1993 | H & H PRODUCING | 2659.00 | 0.00 | 275 |
1994 | CRISSINGER ROBERT A INC | 240.00 | 0.00 | 120 |
1995 | CRISSINGER ROBERT A INC | 132.00 | 0.00 | 365 |
1996 | CRISSINGER ROBERT A INC | 10.00 | 0.00 | 365 |
1997 | CRISSINGER ROBERT A INC | 1892.00 | 0.00 | 365 |
1998 | JD PRODUCING INC | 344.00 | 0.00 | 210 |
1999 | JD PRODUCING INC | 2655.00 | 45.00 | 365 |
2000 | JD PRODUCING INC | 2368.00 | 0.00 | 365 |
2001 | JD PRODUCING INC | 2366.00 | 0.00 | 365 |
2002 | JD PRODUCING INC | 2652.00 | 0.00 | 365 |
2003 | JD PRODUCING INC | 2694.00 | 0.00 | 365 |
2004 | JD PRODUCING INC | 2134.00 | 0.00 | 365 |
2005 | JD PRODUCING INC | 1904.00 | 0.00 | 365 |
2006 | JD PRODUCING INC | 1259.00 | 0.00 | 365 |
2007 | JD PRODUCING INC | 1188.00 | 0.00 | 365 |
2008 | JD PRODUCING INC | 542.00 | 0.00 | 365 |
2009 | JD PRODUCING INC | 282.00 | 0.00 | 365 |
2010 | JD PRODUCING INC | 250.00 | 0.00 | 365 |
2011 | JD PRODUCING INC | 390.00 | 0.00 | 365 |
2012 | JD PRODUCING INC | 381.00 | 0.00 | 366 |
2013 | S & S ENERGY CORP | 398.00 | 0.00 | 365 |
2014 | S & S ENERGY CORP | 315.00 | 0.00 | 365 |
2015 | S & S ENERGY CORP | 280.00 | 0.00 | 282 |
2016 | S & S ENERGY CORP | 224.00 | 0.00 | 365 |
2017 | MS PRODUCING LLC | 44.00 | 0.00 | 365 |
2018 | MS PRODUCING LLC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1990 | CRISSINGER ROBERT A INC | Brine | 0 | 182 |
1991 | CRISSINGER ROBERT A INC | Brine | 0 | 365 |
1992 | CRISSINGER ROBERT A INC | Brine | 0 | 365 |
1993 | H & H PRODUCING | Brine | 0 | 275 |
1994 | CRISSINGER ROBERT A INC | Brine | 0 | 120 |
1995 | CRISSINGER ROBERT A INC | Brine | 0 | 365 |
1996 | CRISSINGER ROBERT A INC | Brine | 40 | 365 |
1997 | CRISSINGER ROBERT A INC | Brine | 0 | 365 |
1998 | JD PRODUCING INC | Brine | 0 | 210 |
1999 | JD PRODUCING INC | Brine | 0 | 365 |
2000 | JD PRODUCING INC | Brine | 0 | 365 |
2001 | JD PRODUCING INC | Brine | 0 | 365 |
2002 | JD PRODUCING INC | Brine | 0 | 365 |
2003 | JD PRODUCING INC | Brine | 0 | 365 |
2004 | JD PRODUCING INC | Brine | 0 | 365 |
2005 | JD PRODUCING INC | Brine | 0 | 365 |
2006 | JD PRODUCING INC | Brine | 0 | 365 |
2007 | JD PRODUCING INC | Brine | 0 | 365 |
2008 | JD PRODUCING INC | Brine | 0 | 365 |
2009 | JD PRODUCING INC | Brine | 0 | 365 |
2010 | JD PRODUCING INC | Brine | 0 | 365 |
2011 | JD PRODUCING INC | Brine | 0 | 365 |
2012 | JD PRODUCING INC | Brine | 0 | 366 |
2013 | S & S ENERGY CORP | Brine | 0 | 365 |
2014 | S & S ENERGY CORP | Brine | 0 | 365 |
2015 | S & S ENERGY CORP | Brine | 0 | 282 |
2016 | S & S ENERGY CORP | Brine | 0 | 365 |
2017 | MS PRODUCING LLC | Brine | 0 | 365 |
2018 | MS PRODUCING LLC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1832500828 | 2020-6-3 0:00:0 | PW | No Violations | |
-1836245544 | 2018-3-23 0:00: | PW | No Violations | |
-199541598 | 2017-8-25 0:00: | PW | No Violations | |
00000PL432 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0199541598 | 2017-08-25 | Production Wells | No Violations | Inspected production well on 08/25/2017. The tank battery consists of 3-100 bbl steel tanks, 1-50 bbl steel tank, 4-vertical separators, 2-drips, 2-meters, and 4-meter boxes, located within an earthen dike; the diked area is located within a locked metal fence. The tank battery is used by multiple wells (4); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, drip, regulator, and meter. Well identification is posted at the wellhead as required. All well identification issues noted in the previous inspection have been addressed, and no problems were noted at the time of the inspection. |
0624451891 | 2016-11-01 | Production Wells | No Violations | Inspected production well on 11/01/2016. The tank battery consists of 3-100 bbl steel tanks, 1-50 bbl steel tank, and 4-vertical separator, located within an earthen dike; the diked area is located within a locked metal fence. The tank battery is used by multiple wells (4); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. No well identification is posted at the wellhead as required. Jason with S&S Energy was notified of this issue and will address it promptly. No other problems were noted at the time of the inspection. |
0986036777 | 2017-07-10 | Production Wells | No Violations | Inspected production well on 07/10/2017. The tank battery consists of 3-100 bbl steel tanks, 1-50 bbl steel tank, 4-vertical separators, 2-drips, 2-meters, and 4-meter boxes, located within an earthen dike; the diked area is located within a locked metal fence. The tank battery is used by multiple wells (4); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, a drip, and meter. No well identification is posted at the wellhead as required. Jim, the well tender, was notified of this issue and will address it promptly. No other problems were noted at the time of the inspection. |
1836245544 | 2018-03-23 | Production Wells | No Violations | Inspected production well on 03/23/2018. The tank battery consists of 3-100 bbl steel tanks, 1-50 bbl steel tank, 4-vertical separators, 2-meters with 2-drips and 2-regulators, and 4-meter boxes, located within an earthen dike; the diked area is located within an unlocked metal fence. The tank battery is used by multiple wells (4); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, and 1-meter with a drip and regulator. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
624451891 | 2016-11-1 0:00: | PW | No Violations | |
986036777 | 2017-7-10 0:00: | PW | No Violations | |
PL432 | PL | No Violations |
For data sources see[9]