{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.84,"lon":-81.9,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: MORMACK IND INC | |
Well Pad ID: | |
Farm/Lease Name: MYRTLE FARMS INC | |
License Status: Producing | |
License Date: 1988-02-19 | |
Spud Date: 1988-02-22 | |
Spud Drilling Contractor: G & H DRLG | |
Final Drill Date: 1988-02-27 | |
Well Total Depth: 3600.00 ft | |
Configuration: Vertical | |
Latitude: 40.840000 | |
Longitude: -81.900000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1988-02-19 | Issued Date 2/19/88 Expired Date 2/18/89 Acres 0020000 Tool Type CRAF Proposed Formation CLINTON Proposed Depth 03600 Proposed Drill Depth 03600 |
Original Spud | 1988-02-22 | |
Completed | 1988-02-27 | |
Reached Total Depth | 1988-02-27 | |
CO | 1988-03-17 | 2002 CASCADE PETROLEUM INC GeoDate 2/19/88 |
Completion Report Received | 1988-03-21 | |
Construction Permit Expires | 1989-02-18 | |
CO | 1994-01-28 | 182 BELDEN & BLAKE CO GeoDate 2/19/88 |
Change of Owner | 1997-12-26 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 1383, OHIO L & M CO INC |
Change of Owner | 1998-10-21 | Operator changed from 1383, OHIO L & M CO INC to 4969, C & T ENTERPRISES |
Change of Owner | 2007-07-11 | Operator changed from 4969, C & T ENERGY OF EAST CANTON to 217, MORMACK IND INC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3454 | 3538 | 0 |
3454 | 3538 | 0 | |
2006-09-11 | 3479 | 3535 | 18 |
3479 | 3535 | 18 | |
3454 | 3538 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 62000 Gal | 0 | FRAC: H2O,SAND,N2 | ||
N2 | 0 | 180 Mscf | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1988 | CASCADE PETROLEUM INC | 20362.00 | 0.00 | 180 |
1989 | CASCADE PETROLEUM INC | 29670.00 | 0.00 | 365 |
1990 | CASCADE PETROLEUM INC | 14616.00 | 54.00 | 365 |
1991 | CASCADE PETROLEUM INC | 4591.00 | 0.00 | 365 |
1992 | CASCADE PETROLEUM INC | 2499.00 | 0.00 | 365 |
1993 | BELDEN & BLAKE CORPORATION | 1847.00 | 0.00 | 366 |
1994 | BELDEN & BLAKE CORPORATION | 1052.00 | 0.00 | 339 |
1995 | BELDEN & BLAKE CORPORATION | 3165.00 | 0.00 | 358 |
1996 | BELDEN & BLAKE CORPORATION | 529.00 | 0.00 | 108 |
1997 | BELDEN & BLAKE CORPORATION | 0.00 | 0.00 | 21 |
1998 | BELDEN & BLAKE CORPORATION | 0.00 | 32.00 | 365 |
2000 | C & T ENERGY OF EAST CANTON IN | 817.00 | 0.00 | 365 |
2001 | C & T ENERGY OF EAST CANTON IN | 706.00 | 32.00 | 365 |
2002 | C & T ENERGY OF EAST CANTON IN | 472.00 | 0.00 | 365 |
2003 | C & T ENERGY OF EAST CANTON IN | 201.00 | 0.00 | 365 |
2004 | C & T ENERGY OF EAST CANTON IN | 651.00 | 0.00 | 365 |
2005 | C & T ENERGY OF EAST CANTON IN | 947.00 | 0.00 | 365 |
2006 | C & T ENERGY OF EAST CANTON IN | 1075.00 | 0.00 | 365 |
2007 | MORMACK IND INC | 178.00 | 0.00 | 365 |
2008 | MORMACK IND INC | 649.00 | 0.00 | 365 |
2009 | MORMACK IND INC | 806.00 | 0.00 | 365 |
2010 | MORMACK IND INC | 874.00 | 0.00 | 365 |
2011 | MORMACK IND INC | 1094.00 | 0.00 | 0 |
2012 | MORMACK IND INC | 621.00 | 0.00 | 366 |
2013 | MORMACK IND INC | 997.00 | 0.00 | 365 |
2014 | MORMACK IND INC | 870.00 | 0.00 | 365 |
2015 | MORMACK IND INC | 379.00 | 0.00 | 365 |
2016 | MORMACK IND INC | 0.00 | 0.00 | 0 |
2017 | MORMACK IND INC | 1.00 | 0.00 | 365 |
2018 | MORMACK IND INC | 22.00 | 0.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1456531645 | 2016-6-9 0:00:0 | PW | No Violations | |
-1492096843 | 2017-9-20 0:00: | PW | No Violations | |
-369849563 | 2013-7-1 0:00:0 | PW | No Violations | 0.50 |
00000PL179 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0369849563 | 2013-07-01 | Production Wells | No Violations | This is a plunger lift well. No apparent problems at this time. |
0369965995 | 2014-08-07 | Production Wells | No Violations | This is now a pumping unit well. There are no apparent problems at time of inspection. |
1456531645 | 2016-06-09 | Production Wells | No Violations | Inspected production well on 06/09/2016. The tank battery consists of 1-100 bbl steel tank, 1-1,600 gal plastic tank, and 1-vertical separator, located within an earthen dike. The plastic tank is caved in, and needs to be removed. Ed Mack with Mormack, was notified of this issue and will have it addressed promptly. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with a natural gas-powered motor. No other problems were noted at the time of the inspection. |
1492096843 | 2017-09-20 | Production Wells | No Violations | Inspected production well on 09/20/2017. The tank battery consists of 1-100 bbl steel tank, 1-1,600 gal plastic tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. The top of the plastic tank was noted to be caved-in, but the tank did not appear to be in-use at the time of the inspection. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with a natural gas-powered motor. No problems were noted at the time of the inspection. |
1537193268 | 2018-08-01 | Production Wells | No Violations | Inspected production well on 08/01/2018. The tank battery consists of 1-100 bbl steel tank, 1-1,600 gal plastic tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with a natural gas-powered motor. The well is located ~100 from its RBDMS location. A comparison of the well location with the original plat indicated that the permit number is correct, only the location is incorrect. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Gregg Miller and Aaron Lantz (DOGRM Columbus). No other problems were noted at the time of the inspection. |
369965995 | 2014-8-7 0:00:0 | PW | No Violations | 0.50 |
PL179 | PL | No Violations |