X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-24916

Well Details

Well ID: 34-169-24916
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Green Township
Operator Name: C & C PRODUCING LLC
Well Pad ID:
Farm/Lease Name: THUT R& S
License Status: Producing
License Date: 1992-09-14
Spud Date: 1992-09-18
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1992-09-26
Well Total Depth: 5992.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -81.790000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1992-09-14 461 OBERMILLER PAUL J GeoDate 9/14/92
Oil and Gas 1992-09-14 Issued Date 9/14/92 Expired Date 9/14/93 Acres 0040000 Tool Type RTAF Proposed Formation CL/TREMPEALEAU Proposed Depth 05992 Proposed Drill Depth 05992
Original Spud 1992-09-18
Completed 1992-09-26
Reached Total Depth 1992-09-26
Completion Report Received 1992-12-22
Construction Permit Expires 1993-09-14
Change of Owner 2013-12-06 Operator changed from 461, OBERMILLER PAUL J to 8423, C & C PRODUCING LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3490 3572 0
3490 3572 0
2006-09-11 3507 3572 18
3507 3572 18
3490 3572 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2100 Bbl 30000 FRAC W/2100 BW & 300 SX SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 OBERMILLER PAUL J 0.00 0.00 339
1994 OBERMILLER PAUL J 0.00 0.00 0
1995 OBERMILLER PAUL J 7758.00 120.00 365
1996 OBERMILLER PAUL J 0.00 0.00 365
1997 OBERMILLER PAUL J 6202.00 39.00 365
1998 OBERMILLER PAUL J 5115.00 23.00 365
1999 OBERMILLER PAUL J 3430.00 66.00 365
2000 OBERMILLER PAUL J 5697.00 39.00 365
2001 OBERMILLER PAUL J 3611.00 41.00 365
2002 OBERMILLER PAUL J 2707.00 17.00 365
2003 OBERMILLER PAUL J 2359.00 17.00 365
2004 OBERMILLER PAUL J 2168.00 32.00 365
2005 OBERMILLER PAUL J 1981.00 15.00 365
2006 OBERMILLER PAUL J 2100.00 0.00 365
2007 OBERMILLER PAUL J 1858.00 19.00 365
2008 OBERMILLER PAUL J 1641.00 0.00 365
2009 OBERMILLER PAUL J 1842.00 18.00 365
2010 OBERMILLER PAUL J 1714.00 0.00 365
2011 OBERMILLER PAUL J 1592.00 21.00 365
2012 OBERMILLER PAUL J 1550.00 12.00 366
2013 OBERMILLER PAUL J 1222.00 14.00 365
2014 C & C PRODUCING LLC 1242.00 0.00 365
2015 C & C PRODUCING LLC 1019.00 13.00 365
2016 C & C PRODUCING LLC 936.00 0.00 365
2017 C & C PRODUCING LLC 788.00 0.00 365
2018 C & C PRODUCING LLC 1235.00 13.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 OBERMILLER PAUL J Brine 520 339
1994 OBERMILLER PAUL J Brine 0 0
1995 OBERMILLER PAUL J Brine 0 365
1996 OBERMILLER PAUL J Brine 0 365
1997 OBERMILLER PAUL J Brine 0 365
1998 OBERMILLER PAUL J Brine 0 365
1999 OBERMILLER PAUL J Brine 0 365
2000 OBERMILLER PAUL J Brine 0 365
2001 OBERMILLER PAUL J Brine 0 365
2002 OBERMILLER PAUL J Brine 0 365
2003 OBERMILLER PAUL J Brine 0 365
2004 OBERMILLER PAUL J Brine 160 365
2005 OBERMILLER PAUL J Brine 80 365
2006 OBERMILLER PAUL J Brine 85 365
2007 OBERMILLER PAUL J Brine 0 365
2008 OBERMILLER PAUL J Brine 0 365
2009 OBERMILLER PAUL J Brine 160 365
2010 OBERMILLER PAUL J Brine 540 365
2011 OBERMILLER PAUL J Brine 16 365
2012 OBERMILLER PAUL J Brine 16 366
2013 OBERMILLER PAUL J Brine 24 365
2014 C & C PRODUCING LLC Brine 25 365
2015 C & C PRODUCING LLC Brine 26 365
2016 C & C PRODUCING LLC Brine 18 365
2017 C & C PRODUCING LLC Brine 17 365
2018 C & C PRODUCING LLC Brine 11 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-126930919 2017-4-28 0:00: PW No Violations
-1537976263 2016-7-20 0:00: PW No Violations
-1933655469 2018-6-7 0:00:0 PW No Violations
-637408666 2017-4-28 0:00: PL No Violations
-732079043 2020-6-8 0:00:0 PW No Violations
0000019708 Preliminary Restoration No Violations PASSED Y WITNESSED 6/14/93 INSPECTOR HAROLD MORAVY DATE 06/1419/93 DATA FROM OLD VAX INFO
0126930919 2017-04-28 Production Wells No Violations Inspected production well on 04/28/2017. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator, located within an earthen dike. The tank battery is used by multiple wells (5); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with a natural gas-powered hitmiss motor, and 1-50 bbl steel tank. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
0637408666 2017-04-28 Preliminary Restoration No Violations Inspected production well on 04/28/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0687958086 2014-12-09 Production Wells No Violations Pumping unit well with no apparent problems. Exceedingly wet field prohibits ability to GPS well head.
1537976263 2016-07-20 Production Wells No Violations Inspected production well on 07/20/2016. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator, located within an earthen dike. The tank battery is used by multiple wells (5); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with a natural gas-powered motor. Well identification is posted at the wellhead as required. 1-50 bbl steel tank is located next to the wellhead, however there is no dike around it. Matt Csapo with C&C Producing, was notified of this issue and will address it promptly. No other problems were noted at the time of the inspection.
1933655469 2018-06-07 Production Wells No Violations Inspected production well on 06/07/2018. The tank battery consists of 2-100 bbl steel tanks, 1-vertical separator, 1-meter with a drip and regulator, and 1-meter box, located within an earthen dike. The tank battery is used by multiple wells (5); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with a natural gas-powered motor, and 1-50 bbl steel tank, all located within electric fencing. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
19708 PL No Violations
687958086 2014-12-9 0:00: PW No Violations 0.50

For data sources see[9]

References