If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-25027 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.93,"lon":-81.93,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Canaan Township | |
Operator Name: C & C PRODUCING LLC | |
Well Pad ID: | |
Farm/Lease Name: FRANKS MILDRED | |
License Status: Producing | |
License Date: 1995-01-31 | |
Spud Date: 1995-02-24 | |
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]] | |
Final Drill Date: 1995-03-01 | |
Well Total Depth: 5520.00 ft | |
Configuration: Vertical | |
Latitude: 40.930000 | |
Longitude: -81.930000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1995-01-31 | Issued Date 1/31/95 Expired Date 1/31/96 Acres 0093535 Tool Type RTAF Proposed Formation CLINTON/TPLU Proposed Depth 05520 Proposed Drill Depth 05520 |
Original Spud | 1995-02-24 | |
Completed | 1995-03-01 | |
Reached Total Depth | 1995-03-01 | |
CO | 1995-04-08 | 461 OBERMILLER PAUL J GeoDate 1/31/95 |
Completion Report Received | 1995-07-05 | |
Construction Permit Expires | 1996-01-31 | |
Change of Owner | 2013-12-06 | Operator changed from 461, OBERMILLER PAUL J to 8423, C & C PRODUCING LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5495 | 0 | |
5495 | 0 | ||
5495 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 2500 Gal | 0 | TREATED W/2500 GAL 15% FE ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | OBERMILLER PAUL J | 9653.00 | 2349.00 | 269 |
1996 | OBERMILLER PAUL J | 53790.00 | 3341.00 | 365 |
1997 | OBERMILLER PAUL J | 26494.00 | 876.00 | 365 |
1998 | OBERMILLER PAUL J | 19937.00 | 367.00 | 365 |
1999 | OBERMILLER PAUL J | 9148.00 | 247.00 | 365 |
2000 | OBERMILLER PAUL J | 5285.00 | 248.00 | 365 |
2001 | OBERMILLER PAUL J | 3427.00 | 188.00 | 365 |
2002 | OBERMILLER PAUL J | 2447.00 | 211.00 | 365 |
2003 | OBERMILLER PAUL J | 1787.00 | 126.00 | 365 |
2004 | OBERMILLER PAUL J | 1682.00 | 117.00 | 365 |
2005 | OBERMILLER PAUL J | 1040.00 | 121.00 | 365 |
2006 | OBERMILLER PAUL J | 894.00 | 120.00 | 365 |
2007 | OBERMILLER PAUL J | 952.00 | 120.00 | 365 |
2008 | OBERMILLER PAUL J | 771.00 | 142.00 | 365 |
2009 | OBERMILLER PAUL J | 1146.00 | 121.00 | 365 |
2010 | OBERMILLER PAUL J | 1251.00 | 127.00 | 365 |
2011 | OBERMILLER PAUL J | 1335.00 | 59.00 | 365 |
2012 | OBERMILLER PAUL J | 1626.00 | 124.00 | 366 |
2013 | OBERMILLER PAUL J | 1151.00 | 63.00 | 365 |
2014 | C & C PRODUCING LLC | 1116.00 | 154.00 | 365 |
2015 | C & C PRODUCING LLC | 883.00 | 69.00 | 365 |
2016 | C & C PRODUCING LLC | 977.00 | 70.00 | 365 |
2017 | C & C PRODUCING LLC | 915.00 | 63.00 | 365 |
2018 | C & C PRODUCING LLC | 718.00 | 27.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | OBERMILLER PAUL J | Brine | 1380 | 269 |
1996 | OBERMILLER PAUL J | Brine | 0 | 365 |
1997 | OBERMILLER PAUL J | Brine | 0 | 365 |
1998 | OBERMILLER PAUL J | Brine | 0 | 365 |
1999 | OBERMILLER PAUL J | Brine | 0 | 365 |
2000 | OBERMILLER PAUL J | Brine | 9 | 365 |
2001 | OBERMILLER PAUL J | Brine | 0 | 365 |
2002 | OBERMILLER PAUL J | Brine | 0 | 365 |
2003 | OBERMILLER PAUL J | Brine | 0 | 365 |
2004 | OBERMILLER PAUL J | Brine | 0 | 365 |
2005 | OBERMILLER PAUL J | Brine | 0 | 365 |
2006 | OBERMILLER PAUL J | Brine | 0 | 365 |
2007 | OBERMILLER PAUL J | Brine | 0 | 365 |
2008 | OBERMILLER PAUL J | Brine | 0 | 365 |
2009 | OBERMILLER PAUL J | Brine | 0 | 365 |
2010 | OBERMILLER PAUL J | Brine | 0 | 365 |
2011 | OBERMILLER PAUL J | Brine | 0 | 365 |
2012 | OBERMILLER PAUL J | Brine | 0 | 366 |
2013 | OBERMILLER PAUL J | Brine | 6 | 365 |
2014 | C & C PRODUCING LLC | Brine | 0 | 365 |
2015 | C & C PRODUCING LLC | Brine | 0 | 365 |
2016 | C & C PRODUCING LLC | Brine | 7 | 365 |
2017 | C & C PRODUCING LLC | Brine | 4 | 365 |
2018 | C & C PRODUCING LLC | Brine | 2 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1037113588 | 2017-4-4 0:00:0 | PL | No Violations | |
-1317901037 | 2018-5-22 0:00: | PW | No Violations | |
-1325941481 | 2017-4-4 0:00:0 | PW | No Violations | |
-664539882 | 2016-3-15 0:00: | PW | No Violations | |
0008331621 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 5/11/95 INSPECTOR MARK MORELAND DATE 05/1119/95 DATA FROM OLD VAX INFO | |
0664539882 | 2016-03-15 | Production Wells | No Violations | Inspected production well on 03/15/2016. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
1037113588 | 2017-04-04 | Preliminary Restoration | No Violations | Inspected production well on 04/04/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
1317901037 | 2018-05-22 | Production Wells | No Violations | Inspected production well on 05/22/2018. The tank battery consists of 2-100 bbl steel tanks, 1-vertical separator, 1-meter with a drip and regulator, 1-drip, and 1-meter box, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, located within barbed-wire/electric fencing. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
1325941481 | 2017-04-04 | Production Wells | No Violations | Inspected production well on 04/04/2017. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, located within electric fencing. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
8331621 | PL | No Violations |
For data sources see[9]