Well ID: 34-169-25318 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.84,"lon":-82.03,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Chester Township | |
Operator Name: DERBY OPERATING CORP | |
Well Pad ID: | |
Farm/Lease Name: CORBETT JOHN | |
License Status: Final Restoration | |
License Date: 2016-09-06 | |
Spud Date: 1999-11-22 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 1999-12-02 | |
Well Total Depth: 5440.00 ft | |
Configuration: Vertical | |
Latitude: 40.840000 | |
Longitude: -82.030000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 1999-11-15 | Proposed Formations:TREMPEALEAU, Issued Date:11/15/99, Expired Date:11/14/2000 6:00:00 AM, Drilling unit acres:47.6, Proposed Well Type:OG, Proposed Well Class:EOUT |
Original Spud | 1999-11-22 | RBDMS Rec |
Completed | 1999-12-02 | RBDMS Rec |
Reached Total Depth | 1999-12-02 | RBDMS Rec |
Completion Report Received | 2000-07-21 | RBDMS Rec |
Change of Owner | 2003-01-08 | Operator changed from 4653, RED BIRD PRODUCING CO to 2892, DERBY OPERATING CORP |
APP | 2016-09-06 | Proposed Formations:TREMPEALEAU, Issued Date:9/6/2016, Expired Date:9/6/2018 12:00:00 PM, Drilling unit acres:47.6, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2016-09-21 | RBDMS Rec |
Record Last Modified | 2018-04-07 | RBDMS Rec |
Construction Permit Expires | 2018-09-06 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-10-12 | 5418 | 5430 | 25 |
2000-10-12 | 5420 | 5425 | 15 |
5418 | 5430 | 25 | |
5420 | 5425 | 15 | |
5418 | 5430 | 25 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 1300 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | DERBY OPERATING CORP | 13030.00 | 0.00 | 331 |
2001 | DERBY OPERATING CORP | 7051.00 | 0.00 | 331 |
2002 | DERBY OPERATING CORP | 2402.00 | 0.00 | 365 |
2003 | DERBY OPERATING CORP | 3090.00 | 0.00 | 365 |
2004 | DERBY OPERATING CORP | 2284.00 | 0.00 | 365 |
2005 | DERBY OPERATING CORP | 1748.00 | 0.00 | 365 |
2006 | DERBY OPERATING CORP | 241.00 | 0.00 | 365 |
2007 | DERBY OPERATING CORP | 425.00 | 0.00 | 365 |
2008 | DERBY OPERATING CORP | 1.00 | 0.00 | 365 |
2009 | DERBY OPERATING CORP | 1040.00 | 549.00 | 365 |
2010 | DERBY OPERATING CORP | 2115.00 | 596.00 | 365 |
2011 | DERBY OPERATING CORP | 1067.00 | 281.00 | 365 |
2012 | DERBY OPERATING CORP | 803.00 | 210.00 | 366 |
2013 | DERBY OPERATING CORP | 698.00 | 151.00 | 365 |
2014 | DERBY OPERATING CORP | 646.00 | 70.00 | 365 |
2015 | DERBY OPERATING CORP | 404.00 | 76.00 | 365 |
2016 | DERBY OPERATING CORP | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | DERBY OPERATING CORP | Brine | 0 | 331 |
2001 | DERBY OPERATING CORP | Brine | 0 | 331 |
2002 | DERBY OPERATING CORP | Brine | 80 | 365 |
2003 | DERBY OPERATING CORP | Brine | 0 | 365 |
2004 | DERBY OPERATING CORP | Brine | 0 | 365 |
2005 | DERBY OPERATING CORP | Brine | 0 | 365 |
2006 | DERBY OPERATING CORP | Brine | 0 | 365 |
2007 | DERBY OPERATING CORP | Brine | 0 | 365 |
2008 | DERBY OPERATING CORP | Brine | 0 | 365 |
2009 | DERBY OPERATING CORP | Brine | 2418 | 365 |
2010 | DERBY OPERATING CORP | Brine | 3884 | 365 |
2011 | DERBY OPERATING CORP | Brine | 2909 | 365 |
2012 | DERBY OPERATING CORP | Brine | 10665 | 366 |
2013 | DERBY OPERATING CORP | Brine | 2195 | 365 |
2014 | DERBY OPERATING CORP | Brine | 1585 | 365 |
2015 | DERBY OPERATING CORP | Brine | 1460 | 365 |
2016 | DERBY OPERATING CORP | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1033557818 | 2018-2-5 0:00:0 | FR | No Violations | |
-1967134169 | 2016-9-22 0:00: | PB | No Violations | |
-207604525 | 2014-12-31 0:00 | PW | No Violations | 0.50 |
0207604525 | 2014-12-31 | Production Wells | No Violations | This is a pumping unit well. There are no apparent problems at time of inspection. |
1033557818 | 2018-02-05 | Final Restoration | No Violations | Visited location on 02/05/2018 to complete the final restoration inspection. No surface expression of the well, production equipment, or lease road were noted at the time of the inspection. Final restoration passes. |
1069248981 | 2012-11-19 | Production Wells | No Violations | This is a producing pump jack well. It was pumping when I was there. There were no problems noted at the time of the inspection. |
1208715264 | 2016-03-22 | Production Wells | No Violations | Inspected production well on 03/22/2016. The tank battery consists of 2-100 bbl steel tanks, 1-50 bbl steel tank, and 1-vertical separator located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |
1384523072 | 2013-11-15 | Production Wells | No Violations | This is a pumping unit well in operation at time of inspection. No apparent problems at this time. |
1967134169 | 2016-09-22 | Plug / Plug Back | No Violations | Visited location on 09/22/2016 to follow-up on plugging operations. Bremer Steam Service and Gary Miller (Derby Operating Corp) were on-site to steam clean tubing removed from the well for plugging. The well was covered up by the liner used for steaming, so the top of cement could not be checked. Will follow-up. No problems were noted at the time of the inspection. |
iDIAN00402 | 2000-05-04 | Preliminary Restoration | No Violations | |
iDIAN004021 | 2000-5-4 0:00:0 | PL | No Violations |