Well ID: 34-169-25350 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.88,"lon":-81.98,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Wayne Township | |
Operator Name: MORMACK IND INC | |
Well Pad ID: | |
Farm/Lease Name: SNYDER JAMIE # 4` | |
License Status: Producing | |
License Date: 2000-08-09 | |
Spud Date: 2000-09-21 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2000-09-29 | |
Well Total Depth: 5625.00 ft | |
Configuration: Vertical | |
Latitude: 40.880000 | |
Longitude: -81.980000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2000-08-09 | 4653 RED BIRD PRODUCING CO Proposed Formation TREMPEALEAU Issued Date 8/9/00 Expired Date 8/9/01 6:00:00 AM |
Original Spud | 2000-09-21 | RBDMS Rec |
Completed | 2000-09-29 | RBDMS Rec |
Reached Total Depth | 2000-09-29 | RBDMS Rec |
Completion Report Received | 2001-01-04 | RBDMS Rec |
Correction to Well | 2001-07-06 | CHANGE IN UNIT SIZE TO 120 ACRES. |
Construction Permit Expires | 2001-08-09 | RBDMS Rec |
Change of Owner | 2001-08-17 | Operator changed from 4653, RED BIRD PRODUCING CO to 217, MORMACK IND INC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2001-02-27 | 5522 | 5532 | 0 |
2001-02-27 | 5560 | 5570 | 0 |
5560 | 5570 | 0 | |
5522 | 5532 | 0 | |
5522 | 5532 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 2000 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | MORMACK IND INC | 52047.00 | 444.00 | 52 |
2001 | MORMACK IND INC | 115752.00 | 5272.00 | 365 |
2002 | MORMACK IND INC | 60856.00 | 3202.00 | 365 |
2003 | MORMACK IND INC | 22444.00 | 2082.00 | 365 |
2004 | MORMACK IND INC | 13762.00 | 1658.00 | 365 |
2005 | MORMACK IND INC | 19393.00 | 1408.00 | 365 |
2006 | MORMACK IND INC | 6001.00 | 1013.00 | 365 |
2007 | MORMACK IND INC | 3904.00 | 877.00 | 365 |
2008 | MORMACK IND INC | 2456.00 | 651.00 | 365 |
2009 | MORMACK IND INC | 2200.00 | 535.00 | 365 |
2010 | MORMACK IND INC | 2006.00 | 484.00 | 365 |
2011 | MORMACK IND INC | 1805.00 | 493.00 | 0 |
2012 | MORMACK IND INC | 2633.00 | 646.00 | 366 |
2013 | MORMACK IND INC | 2771.00 | 549.00 | 365 |
2014 | MORMACK IND INC | 1847.00 | 495.00 | 365 |
2015 | MORMACK IND INC | 1452.00 | 356.00 | 365 |
2016 | MORMACK IND INC | 1422.00 | 321.00 | 365 |
2017 | MORMACK IND INC | 1166.00 | 242.00 | 365 |
2018 | MORMACK IND INC | 852.00 | 232.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | MORMACK IND INC | Brine | 52 | |
2001 | MORMACK IND INC | Brine | 0 | 365 |
2002 | MORMACK IND INC | Brine | 24 | 365 |
2003 | MORMACK IND INC | Brine | 0 | 365 |
2004 | MORMACK IND INC | Brine | 0 | 365 |
2005 | MORMACK IND INC | Brine | 0 | 365 |
2006 | MORMACK IND INC | Brine | 23 | 365 |
2007 | MORMACK IND INC | Brine | 27 | 365 |
2008 | MORMACK IND INC | Brine | 0 | 365 |
2009 | MORMACK IND INC | Brine | 0 | 365 |
2010 | MORMACK IND INC | Brine | 0 | 365 |
2011 | MORMACK IND INC | Brine | 19 | |
2012 | MORMACK IND INC | Brine | 22 | 366 |
2013 | MORMACK IND INC | Brine | 25 | 365 |
2014 | MORMACK IND INC | Brine | 13 | 365 |
2015 | MORMACK IND INC | Brine | 29 | 365 |
2016 | MORMACK IND INC | Brine | 0 | 365 |
2017 | MORMACK IND INC | Brine | 0 | 365 |
2018 | MORMACK IND INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-151955291 | 2016-11-1 0:00: | PL | No Violations | |
-166255180 | 2016-11-1 0:00: | PW | No Violations | |
-258615514 | 2017-5-17 0:00: | PW | No Violations | |
-624523159 | 2020-7-1 0:00:0 | PW | No Violations | |
-931706892 | 2014-12-16 0:00 | PW | No Violations | 0.50 |
0151955291 | 2016-11-01 | Preliminary Restoration | No Violations | Inspected production well on 11/01/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
0166255180 | 2016-11-01 | Production Wells | No Violations | Inspected production well on 11/01/2016 the tank battery was inspected on 11/02/2016. The tank battery consists of 2-210 bbl steel tanks, 2-100 bbl steel tanks, 1-1,900 gal plastic tank, and 1-vertical separator, located within an earthen dike. The tank battery is used by multiple wells (4); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
0258615514 | 2017-05-17 | Production Wells | No Violations | Inspected production well on 05/17/2017. The tank battery consists of 2-210 bbl steel tanks, located within an earthen dike; the diked area is shared with the tank battery for the D. Snyder #1 well (PN: 169-23976). The tank battery is used by multiple wells (3); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
0322079582 | 2016-08-09 | Production Wells | No Violations | Inspected production well on 08/09/2016. The tank battery consists of 2-210 bbl steel tanks, located within an earthen dike; the diked area is shared with the production equipment for the Snyder #1 well (PN: 169-23976). The tank battery is used by multiple wells (3); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. The area immediately around the wellhead needs to be cleaned-up. Ed Mack, with Mormack Inc. was notified of this issue and will have the pumper address it promptly. Well identification is posted at the wellhead as required. No other problems were noted at the time of the inspection. |
0850989226 | 2013-09-26 | Production Wells | No Violations | This is a producing pumping unit well. No apparent problems at time of inspection. |
0931706892 | 2014-12-16 | Production Wells | No Violations | This pumping unit well has no problems that are apparent at this time. |
1478257569 | 2015-11-17 | Production Wells | No Violations | Inspected production well on 11/17/2015. The tank battery consists of 2-210 bbl steel tanks, 2-100 bbl steel tanks, 1-2,000 gal plastic tank, and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells (4); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
1624096290 | 2003-03-31 | Preliminary Restoration | No Violations | |
1693228301 | 2012-11-29 | Production Wells | No Violations | This is a producing pump jack well. There were no problems noted at the time of the inspection. |
1965225391 | 2017-05-17 | Preliminary Restoration | No Violations | Inspected production well on 05/17/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
2147095577 | 2018-07-09 | Production Wells | No Violations | Inspected production well on 07/09/2018. The tank battery consists of 2-210 bbl steel tanks, located within an earthen dike; 2-vertical separators, 1-drip, 1-meter box, and 1-compressor house are located nearby. The diked area is shared with the tank battery for the D. Snyder #1 well (PN: 169-23976). The tank battery is used by multiple wells (3); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
322079582 | 2016-8-9 0:00:0 | PW | No Violations | |
850989226 | 2013-9-26 0:00: | PW | No Violations | 0.50 |
iDIAN00581 | 2001-01-11 | Preliminary Restoration | No Violations | |
iDIAN005815 | 2001-1-11 0:00: | PL | No Violations |
For data sources see[9]