Well Details

Well ID: 34-169-25420
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Wayne Township
Operator Name: HARLEY DRILLING & PRODUCING LT
Well Pad ID:
Farm/Lease Name: JONES
License Status: Producing
License Date: 2001-09-10
Spud Date: 2001-09-13
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2001-09-22
Well Total Depth: 5587.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -81.980000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2001-09-10 337 HARLEY DRILLING & PRODUCI Proposed Formation CLINTON/TREMPEALEAU Issued Date 9/10/01 Expired Date 9/10/02 6:00:00 AM
Original Spud 2001-09-13 RBDMS Rec
Completed 2001-09-22 RBDMS Rec
Reached Total Depth 2001-09-22 RBDMS Rec
Construction Permit Expires 2002-09-10 RBDMS Rec
Completion Report Received 2003-10-15 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-11-21 5518 5544 0
5518 5544 0
5518 5544 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1500 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 HARLEY DRILLING & PRODUCING LT 0.00 2529.00 365
2002 HARLEY DRILLING & PRODUCING LT 49560.00 7967.00 365
2003 HARLEY DRILLING & PRODUCING LT 24663.00 2235.00 365
2004 HARLEY DRILLING & PRODUCING LT 9486.00 867.00 365
2005 HARLEY DRILLING & PRODUCING LT 5911.00 680.00 365
2006 HARLEY DRILLING & PRODUCING LT 4224.00 857.00 365
2007 HARLEY DRILLING & PRODUCING LT 3565.00 1558.00 365
2008 HARLEY DRILLING & PRODUCING LT 3128.00 1390.00 365
2009 HARLEY DRILLING & PRODUCING LT 3171.00 1766.00 365
2010 HARLEY DRILLING & PRODUCING LT 3018.00 1053.00 365
2011 HARLEY DRILLING & PRODUCING LT 2871.00 2713.00 365
2012 HARLEY DRILLING & PRODUCING LT 2916.00 1296.00 366
2013 HARLEY DRILLING & PRODUCING LT 3780.00 2434.00 365
2014 HARLEY DRILLING & PRODUCING LT 1995.00 870.00 365
2015 HARLEY DRILLING & PRODUCING LT 3023.00 2038.00 365
2016 HARLEY DRILLING & PRODUCING LT 3351.00 1560.00 365
2017 HARLEY DRILLING & PRODUCING LT 3003.00 1564.00 365
2018 HARLEY DRILLING & PRODUCING LT 1091.00 1215.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 HARLEY DRILLING & PRODUCING LT Brine 0 365
2002 HARLEY DRILLING & PRODUCING LT Brine 0 365
2003 HARLEY DRILLING & PRODUCING LT Brine 0 365
2004 HARLEY DRILLING & PRODUCING LT Brine 0 365
2005 HARLEY DRILLING & PRODUCING LT Brine 0 365
2006 HARLEY DRILLING & PRODUCING LT Brine 0 365
2007 HARLEY DRILLING & PRODUCING LT Brine 0 365
2008 HARLEY DRILLING & PRODUCING LT Brine 0 365
2009 HARLEY DRILLING & PRODUCING LT Brine 0 365
2010 HARLEY DRILLING & PRODUCING LT Brine 0 365
2011 HARLEY DRILLING & PRODUCING LT Brine 190 365
2012 HARLEY DRILLING & PRODUCING LT Brine 360 366
2013 HARLEY DRILLING & PRODUCING LT Brine 850 365
2014 HARLEY DRILLING & PRODUCING LT Brine 30 365
2015 HARLEY DRILLING & PRODUCING LT Brine 95 365
2016 HARLEY DRILLING & PRODUCING LT Brine 59 365
2017 HARLEY DRILLING & PRODUCING LT Brine 45 365
2018 HARLEY DRILLING & PRODUCING LT Brine 25 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1072832701 2003-6-3 0:00:0 PW No Violations
-1113068156 2004-1-11 0:00: PL No Violations 0.70
-118223062 2014-12-16 0:00 PW No Violations 0.50
-1616603478 2016-3-9 0:00:0 PW No Violations
-2010492191 2012-11-29 0:00 PW No Violations
-63424733 2017-2-1 0:00:0 PL No Violations
-647859029 2013-9-30 0:00: PW No Violations 0.50
-845419008 2016-8-9 0:00:0 PW No Violations
0026978767 2002-10-02 Production Wells No Violations Well is leaking fluid at stuffing box and a pool of oil 3x 3 at well head. No identification on well or tank battery. Called Harley drilling and advised to clean up oil and identify well and tank battery.
0063424733 2017-02-01 Preliminary Restoration No Violations Inspected production well on 02/01/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0118223062 2014-12-16 Production Wells No Violations Pump jack well in operation at time of inspection. No apparent problems at this time.
0647859029 2013-09-30 Production Wells No Violations This is a producing pumping unit that has no apparent problems at this time.
0807557866 2017-02-01 Production Wells No Violations Inspected production well on 02/01/2017. The tank battery consists of 3-210 bbl steel tanks, 1-horizontal separator, 2-vertical separators, 1-compressor, and 1-underground brine vault, located within an earthen dike; the diked area is shared with the tank battery for the Jones #2 and Jentes-Jones #H-6 wells (PN: 169-24148/25561). The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, and a compressor. The well was pumping at the time of the inspection. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
0845419008 2016-08-09 Production Wells No Violations Inspected production well on 08/09/2016. The tank battery consists of 3-210 bbl steel tanks, 2-vertical separators, 1-horizontal separator, 1-compressor, and 1-underground brine vault, located within an earthen dike. The underground brine vault is also used by the Jones #2 and Jones #H-6 wells. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1072832701 2003-06-03 Production Wells No Violations I.D.posted oil removed from tankbattery,and wellhead.
1113068156 2004-01-11 Preliminary Restoration No Violations Meets requirements for preliminary restoration.
1184645324 2018-03-07 Production Wells No Violations Inspected production well on 03/07/2018. The tank battery consists of 2-210 bbl steel tanks, 1-horizontal separator with a drip, 1-meter box with a drip, and 1-underground brine vault (shared), located within an earthen dike; the diked area and noted equipment are shared with the Jentes-Jones #H-4 and #H-6 wells (PN: 169-25432/25561). The well is equipped with a pump jack with an electric motor, and a compressor. The well was pumping at the time of the inspection. Well identification is clearly displayed at both the tank battery and the wellhead. The well is located ~200 from its RBDMS location. A map showing the location discrepancy as well as a request that the location be updated in RBDMS was sent to Gregg Miller (DOGRM Columbus).
1616603478 2016-03-09 Production Wells No Violations Inspected production well on 03/09/2016. The tank battery consists of 3-210 bbl steel tanks, 1-horizontal separator, 2-vertical separators, 1-underground brine vault, and 1-compressor located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. Well identification is posted at the wellhead as required. The well is not located in its RBDMS location. No other problems were noted at the time of the inspection.
1694928503 2007-01-18 Preliminary Restoration No Violations Meets requirements for Primary restoration .
2010492191 2012-11-29 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
26978767 2002-10-2 0:00: PW No Violations 1.00
634200554 2020-6-10 0:00: PW No Violations
807557866 2017-2-1 0:00:0 PW No Violations

For data sources see[9]