X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-25464

Well Details

Well ID: 34-169-25464
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Wayne Township
Operator Name: HARLEY DRILLING & PRODUCING LT
Well Pad ID:
Farm/Lease Name: CARSON DAVID & SUSAN
License Status: Producing
License Date: 2003-03-18
Spud Date: 2003-04-10
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2003-04-14
Well Total Depth: 3496.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -81.970000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-03-18 Proposed Formations:CLINTON, Issued Date:3/18/2003, Expired Date:3/17/2004 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2003-04-10 RBDMS Rec
Completed 2003-04-14 RBDMS Rec
Reached Total Depth 2003-04-14 RBDMS Rec
Completion Report Received 2003-10-06 RBDMS Rec
Construction Permit Expires 2004-03-17 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-11-20 3303 3362 70
3303 3362 70
3303 3362 70

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 10000 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 HARLEY DRILLING & PRODUCING LT 1669.00 1177.00 365
2004 HARLEY DRILLING & PRODUCING LT 5188.00 1400.00 365
2005 HARLEY DRILLING & PRODUCING LT 7340.00 1036.00 365
2006 HARLEY DRILLING & PRODUCING LT 6070.00 1054.00 365
2007 HARLEY DRILLING & PRODUCING LT 6590.00 709.00 365
2008 HARLEY DRILLING & PRODUCING LT 7371.00 511.00 365
2009 HARLEY DRILLING & PRODUCING LT 7691.00 524.00 365
2010 HARLEY DRILLING & PRODUCING LT 7370.00 180.00 365
2011 HARLEY DRILLING & PRODUCING LT 7169.00 521.00 365
2012 HARLEY DRILLING & PRODUCING LT 4746.00 347.00 366
2013 HARLEY DRILLING & PRODUCING LT 2056.00 168.00 365
2014 HARLEY DRILLING & PRODUCING LT 2377.00 170.00 365
2015 HARLEY DRILLING & PRODUCING LT 1650.00 115.00 365
2016 HARLEY DRILLING & PRODUCING LT 2047.00 168.00 365
2017 HARLEY DRILLING & PRODUCING LT 2949.00 171.00 365
2018 HARLEY DRILLING & PRODUCING LT 4273.00 166.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 HARLEY DRILLING & PRODUCING LT Brine 0 365
2004 HARLEY DRILLING & PRODUCING LT Brine 0 365
2005 HARLEY DRILLING & PRODUCING LT Brine 0 365
2006 HARLEY DRILLING & PRODUCING LT Brine 0 365
2007 HARLEY DRILLING & PRODUCING LT Brine 0 365
2008 HARLEY DRILLING & PRODUCING LT Brine 0 365
2009 HARLEY DRILLING & PRODUCING LT Brine 0 365
2010 HARLEY DRILLING & PRODUCING LT Brine 0 365
2011 HARLEY DRILLING & PRODUCING LT Brine 0 365
2012 HARLEY DRILLING & PRODUCING LT Brine 0 366
2013 HARLEY DRILLING & PRODUCING LT Brine 85 365
2014 HARLEY DRILLING & PRODUCING LT Brine 25 365
2015 HARLEY DRILLING & PRODUCING LT Brine 0 365
2016 HARLEY DRILLING & PRODUCING LT Brine 0 365
2017 HARLEY DRILLING & PRODUCING LT Brine 0 365
2018 HARLEY DRILLING & PRODUCING LT Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1124120786 2016-11-2 0:00: PW No Violations
-1153347603 2017-5-17 0:00: PL No Violations
-11559486 2003-6-17 0:00: PW No Violations 0.70
-128788713 2016-11-2 0:00: PL No Violations
-1535094289 2012-11-26 0:00 PW No Violations
-1701438119 2015-12-23 0:00 PW No Violations
-1891956965 2003-6-17 0:00: PW No Violations 0.70
-2012639460 2017-5-17 0:00: PW No Violations
-504372476 2018-7-9 0:00:0 PW No Violations
-685486553 2003-4-30 0:00: DD No Violations 1.00
-869813073 2013-10-10 0:00 PW No Violations 0.50
-938680292 2014-8-7 0:00:0 PW No Violations 0.50
0011559486 2003-06-17 Production Wells No Violations Pits are closed and area needs graded and seeded .
0128788713 2016-11-02 Preliminary Restoration No Violations Inspected production well on 11/02/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0504372476 2018-07-09 Production Wells No Violations Inspected production well on 07/09/2018. The tank battery consists of 1-210 bbl steel tank, 1-100 bbl steel tank (shared), 1-vertical separator, 1-meter box with a drip, and 1-compressor (shared), located within an earthen dike; the diked area and noted equipment are shared with the tank batteries for the D. Carson #H-2, #H-1, and #H-6 wells (PN: 169-25457/25328/25609). The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0685486553 2003-04-30 Drill / Deepen / Reopen No Violations The operator is pumping pits off today and they are just about ready to close . Pits liners are still in place .
0763378126 2003-08-07 Production Wells No Violations This well has just been drilled and pits are closed. Area needs graded and seeded .
0869813073 2013-10-10 Production Wells No Violations This producing pumping unit, in operation at time of inspection, has no apparent problems.
0938680292 2014-08-07 Production Wells No Violations This is a pumping unit well. There are no apparent problems at this time.
1050671487 2003-04-11 Drill / Deepen / Reopen No Violations Capstar Drilling set 489 ft. of 8 5/8 casing c/w 175 sks .
105067148795569 2003-4-11 0:00: PW No Violations 3.50
105067148795741 2003-4-11 0:00: DD No Violations 3.50
1063038088 2003-08-26 Preliminary Restoration No Violations Pits are closed and area needs graded and seeded before restoration can be passed.
1124120786 2016-11-02 Production Wells No Violations Inspected production well on 11/02/2016. The tank battery consists of 4-210 bbl steel tanks, 1-100 bbl steel tank, 2-vertical separators, 1-horizontal separator, and 1-compressor (shared with the Carson #H-6 well; PN: 169-25609), located within an earthen dike (shared with the production equipment for the Carson #H-6 well; PN: 169-25609). The tank battery is used by multiple wells (3); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1153347603 2017-05-17 Preliminary Restoration No Violations Inspected production well on 05/17/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes.
1535094289 2012-11-26 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
1589421220 2020-7-2 0:00:0 PW No Violations
1701438119 2015-12-23 Production Wells No Violations Inspected production well on 12/23/2015. The tank battery consists of 5-210 bbl steel tanks, 2-100 bbl steel tanks, 3-vertical separators, 1-horizontal separator, and 1-compressor located within an earthen dike. The tank battery is used by multiple wells (4); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1891956965 2003-06-17 Production Wells No Violations Pits are closed and area graded , needs seeded .
2012639460 2017-05-17 Production Wells No Violations Inspected production well on 05/17/2017. The tank battery consists of 1-210 bbl steel tank, 1-100 bbl steel tank (shared), 1-vertical separator, and 1-compressor (shared), located within an earthen dike; the diked area is shared with the tank batteries for the D. Carson #H-1, H-2, and H-6 wells (PN: 169-25328/25457/25609). The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
763378126 2003-8-7 0:00:0 PW No Violations 1.00

For data sources see[9]

References