If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-25475 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.77,"lon":-81.99,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Wooster Township | |
Operator Name: KENOIL LLC | |
Well Pad ID: | |
Farm/Lease Name: SHERRICK | |
License Status: Producing | |
License Date: 2003-08-11 | |
Spud Date: 2003-09-20 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2003-09-23 | |
Well Total Depth: 3384.00 ft | |
Configuration: Vertical | |
Latitude: 40.770000 | |
Longitude: -81.990000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2003-08-11 | Proposed Formations:CLINTON, Issued Date:8/11/2003, Expired Date:8/10/2004 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2003-09-20 | RBDMS Rec |
Completed | 2003-09-23 | RBDMS Rec |
Reached Total Depth | 2003-09-23 | RBDMS Rec |
Completion Report Received | 2004-01-09 | RBDMS Rec |
Construction Permit Expires | 2004-08-10 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2004-03-12 | 3183 | 3250 | 79 |
3183 | 3250 | 79 | |
3183 | 3250 | 79 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1800 Bbl | 35000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2004 | KENOIL LLC | 10778.00 | 3395.00 | 365 |
2005 | KENOIL LLC | 8678.00 | 1315.00 | 365 |
2006 | KENOIL LLC | 6204.00 | 748.00 | 365 |
2007 | KENOIL LLC | 4017.00 | 481.00 | 0 |
2008 | KENOIL LLC | 1833.00 | 266.00 | 365 |
2009 | KENOIL LLC | 1108.00 | 270.00 | 365 |
2010 | KENOIL LLC | 1474.00 | 257.00 | 365 |
2011 | KENOIL LLC | 2081.00 | 222.00 | 0 |
2012 | KENOIL LLC | 2253.00 | 211.00 | 366 |
2013 | KENOIL LLC | 2155.00 | 248.00 | 365 |
2014 | KENOIL LLC | 1514.00 | 139.00 | 365 |
2015 | KENOIL LLC | 1133.00 | 137.00 | 365 |
2016 | KENOIL LLC | 965.00 | 181.00 | 365 |
2017 | KENOIL LLC | 1024.00 | 57.00 | 365 |
2018 | KENOIL LLC | 979.00 | 130.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2004 | KENOIL LLC | Brine | 27 | 365 |
2005 | KENOIL LLC | Brine | 0 | 365 |
2006 | KENOIL LLC | Brine | 0 | 365 |
2007 | KENOIL LLC | Brine | 0 | |
2008 | KENOIL LLC | Brine | 0 | 365 |
2009 | KENOIL LLC | Brine | 0 | 365 |
2010 | KENOIL LLC | Brine | 0 | 365 |
2011 | KENOIL LLC | Brine | 20 | |
2012 | KENOIL LLC | Brine | 15 | 366 |
2013 | KENOIL LLC | Brine | 0 | 365 |
2014 | KENOIL LLC | Brine | 0 | 365 |
2015 | KENOIL LLC | Brine | 0 | 365 |
2016 | KENOIL LLC | Brine | 0 | 365 |
2017 | KENOIL LLC | Brine | 0 | 365 |
2018 | KENOIL LLC | Brine | 40 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1149662708 | 2004-9-22 0:00: | PL | No Violations | 1.00 |
-1283577231 | 2015-10-7 0:00: | PW | No Violations | |
-1575095753 | 2005-8-10 0:00: | PW | No Violations | 2.00 |
-1657334947 | 2020-5-11 0:00: | PW | No Violations | |
-1945374056 | 2019-8-15 0:00: | PW | No Violations | |
-588134053 | 2015-9-22 0:00: | PW | No Violations | 0.50 |
-680188716 | 2005-8-22 0:00: | PW | No Violations | 1.70 |
0138014987 | 2017-03-27 | Preliminary Restoration | No Violations | Inspected production well on 03/27/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
0521990289 | 2018-05-04 | Production Wells | No Violations | Inspected production well on 05/04/2018. The tank battery consists of 2-100 bbl steel tanks, 1-1,700 gal plastic tank (shared), 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike; the plastic tank is shared with the Sherrick #3 well (PN: 169-25446). Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor, and 1-meter with a drip and regulator. No problems were noted at the time of the inspection. |
0588134053 | 2015-09-22 | Production Wells | No Violations | This is a pump jack well. No apparent problems at this time. |
0680188716 | 2005-08-22 | Production Wells | No Violations | Check on clean up and found that there are booms and pads which need removed soon .The stream has dried up to only a few inches and almost no flow. |
0789632370 | 2017-03-27 | Production Wells | No Violations | Inspected production well on 03/27/2017. The tank battery consists of 2-100 bbl lsteel tanks, 1-1,600 gal plastic tank (shared with the Sherrick #3 well; PN: 169-25446), and 1-vertical separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor, and a drip, regulator, and meter. No problems were noted at the time of the inspection. |
0866132635 | 2004-04-22 | Preliminary Restoration | No Violations | Pits closed area needs graded and seeded. |
1065021675 | 2003-09-21 | Drill / Deepen / Reopen | No Violations | Arrive to witness casing instalation and cementing. Petorset Cementing service completed job with 150 sks of regular class A cement. |
1065094334 | 2003-09-25 | Drill / Deepen / Reopen | No Violations | Check on rig depth and found that they are done and have moved. Fluid level good in pit and liners still in place. |
1125507790 | 2005-08-09 | Production Wells | No Violations | Had call from Ron Grosjean about a lightening strike and clean up. The tank was hit and about 3 to 5 barrels of oil ran down a field tile into a intermittent stream. They have booms in place and have set up sumps and dikes in front of the oil .The entire amount has been contained and most of the clean up has already taken place .Met clean up crew on site and collected photos and G.P.S reading of where spill started and where it entered the intermittent stream. The stream is two to three ft wide at the largest point and less than one ft at most points .It is several inches deep for the most part. |
1149662708 | 2004-09-22 | Preliminary Restoration | No Violations | Pits closed and area graded and seeded. |
1166027701 | 2006-10-03 | Production Wells | No Violations | Check well after clean up and found the dike is still clean and all booms and oil pads have been removed . |
1223814068 | 2005-09-09 | Production Wells | No Violations | Met clean up crew on site and had them pull all boom ,dikes and pads from the stream.All of the clean up has been done and the clean up is now complete. |
1283577231 | 2015-10-07 | Production Wells | No Violations | Inspected production well on 10/07/2015. The tank battery consists of 2-100 bbl steel tanks, 1-1,600 gal plastic tank, and 1-vertical separator located within an earthen dike. The earthen dike is shared with the production equipment for the Sherrick #3 well (PN: 169-25446). Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |
138014987 | 2017-3-27 0:00: | PL | No Violations | |
1470309193 | 2016-08-02 | Production Wells | No Violations | Inspected production well on 08/02/2016. The tank battery consists of 4-100 bbl steel tanks, 1-1,600 gal plastic tank, and 2-vertical separators, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
1575095753 | 2005-08-10 | Production Wells | No Violations | Check on clean up progress and found that almost all of the oil has been cleaned up and only the dike booms and pads are left to clean up. |
1610535715 | 2014-04-30 | Production Wells | No Violations | This is a pumping unit well. There are no apparent problems at time of inspection. |
521990289 | 2018-5-4 0:00:0 | PW | No Violations | |
789632370 | 2017-3-27 0:00: | PW | No Violations | |
866132635 | 2004-4-22 0:00: | PL | No Violations | 1.00 |
For data sources see[9]