{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.67,"lon":-81.87,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Salt Creek Township | |
Operator Name: INDUSTRY STANDARD SUPPLIES INC | |
Well Pad ID: | |
Farm/Lease Name: ABERNATHY UNIT | |
License Status: Producing | |
License Date: 2006-11-01 | |
Spud Date: 2006-11-16 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2006-11-20 | |
Well Total Depth: 3716.00 ft | |
Configuration: Vertical | |
Latitude: 40.670000 | |
Longitude: -81.870000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-11-01 | Proposed Formations:CLINTON, Issued Date:11/1/2006, Expired Date:11/1/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2006-11-20 | |
Reached Total Depth | 2006-11-20 | |
Completion Report Received | 2007-06-13 | |
Change of Owner | 2007-10-11 | Operator changed from 8104, INDUSTRY STANDARD SUPPLIES INC to 6288, ALLIANCE PETROLEUM CORPORATION |
Construction Permit Expires | 2007-11-01 | |
Change of Owner | 2016-12-13 | Operator changed from 6288, ALLIANCE PETROLEUM CORPORATION to 8104, INDUSTRY STANDARD SUPPLIES INC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2007-10-03 | 3514 | 3580 | 32 |
3514 | 3580 | 32 | |
3514 | 3580 | 32 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 37432 Gal | 60000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | ALLIANCE PETROLEUM CORPORATION | 3820.00 | 0.00 | 321 |
2008 | ALLIANCE PETROLEUM CORPORATION | 23431.00 | 38.00 | 365 |
2009 | ALLIANCE PETROLEUM CORPORATION | 11410.00 | 0.00 | 365 |
2010 | ALLIANCE PETROLEUM CORPORATION | 5695.00 | 0.00 | 365 |
2011 | INDUSTRY STANDARD SUPPLIES INC | 2899.00 | 0.00 | 365 |
2012 | INDUSTRY STANDARD SUPPLIES INC | 4408.00 | 0.00 | 366 |
2013 | INDUSTRY STANDARD SUPPLIES INC | 3892.00 | 45.00 | 365 |
2014 | INDUSTRY STANDARD SUPPLIES INC | 2411.00 | 0.00 | 365 |
2015 | INDUSTRY STANDARD SUPPLIES INC | 2182.00 | 0.00 | 365 |
2016 | INDUSTRY STANDARD SUPPLIES INC | 1641.00 | 40.00 | 365 |
2017 | INDUSTRY STANDARD SUPPLIES INC | 1683.00 | 0.00 | 365 |
2018 | INDUSTRY STANDARD SUPPLIES INC | 1607.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 321 |
2008 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 365 |
2009 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 365 |
2010 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 365 |
2011 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
2012 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 366 |
2013 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
2014 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
2015 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
2016 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
2017 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
2018 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1543893252 | 2018-8-9 0:00:0 | PW | No Violations | |
-1755948069 | 2014-6-26 0:00: | PW | No Violations | 0.50 |
-1857739666 | 2006-11-17 0:00 | DD | No Violations | 4.50 |
-2051120397 | 2017-6-1 0:00:0 | PL | No Violations | |
-459359391 | 2013-1-7 0:00:0 | PW | No Violations | |
-592245411 | 2006-11-21 0:00 | DD | No Violations | 1.50 |
-795761550 | 2016-7-21 0:00: | PW | No Violations | |
-833316788 | 2006-11-20 0:00 | DD | No Violations | 1.50 |
0316554732 | 2015-07-24 | Production Wells | No Violations | This is a plunger lift well. No apparent problems nor compliance issues at this time. |
0459359391 | 2013-01-07 | Production Wells | No Violations | This is a producing plunger lift well. There were no problems noted at the time of the inspection. |
0592245411 | 2006-11-21 | Drill / Deepen / Reopen | No Violations | Capstar Drilling is moving today to Holmes Co. not Stark like the night before .Pit level and liners good . |
0795761550 | 2016-07-21 | Production Wells | No Violations | Inspected production well on 07/21/2016. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator, located within an earthen dike. Well identification is posted at the tank battery, but it is too faded to be legible. Mike Abernathy, with ISSI, was notified of this issue and will have it addressed promptly. The well is a rabbit well. No other problems were noted at the time of the inspection. |
0833316788 | 2006-11-20 | Drill / Deepen / Reopen | No Violations | Capstar Drilling at 3750 ft. on 7 7/8 hole soaping .T.D. shortly near 4001 ft. |
0873560662 | 2016-11-04 | Production Wells | No Violations | Inspected production well on 11/04/2016. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is a rabbit well. A small gas leak was noted at the tubing head. Tim Levengood with Alliance Petroleum Corp. was notified of this issue and will address it promptly. No other problems were noted at the time of the inspection. |
1115407647 | 2016-11-04 | Preliminary Restoration | No Violations | Inspected production well on 11/04/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
1363360341 | 2013-03-15 | Production Wells | No Violations | Well is an 1 1/2 rabbit well. Tank battery consists of 1 100 barrel tank and a steel 50 barrel water tank. Signage is in place and legible. Equipment appears to be in good condition. |
1413129280 | 2006-11-17 | Drill / Deepen / Reopen | No Violations | Check Capstar Drilling and found that they are going to be ready around 5 or 6 tonight . |
1496836090 | 2017-06-01 | Production Wells | No Violations | Inspected production well on 06/01/2017. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, and 1-meter box, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is a rabbit well, equipped with a meter. No problems were noted at the time of the inspection. |
1543893252 | 2018-08-09 | Production Wells | No Violations | Inspected production well on 08/09/2018. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is a rabbit well, equipped with 1-meter with 1-drip and 2-regulators. No problems were noted at the time of the inspection. |
1755948069 | 2014-06-26 | Production Wells | No Violations | This is a plunger lift well. There appears to be no obvious problems at time of inspection. |
1857739666 | 2006-11-17 | Drill / Deepen / Reopen | No Violations | Capstar Drilling set 426 ft. of 8 5/8 casing c/w 180 sks -Petroset - John . 11 hole to 465 ft .23lb pipe. Good returns |
1877625898 | 2006-11-13 | Drill / Deepen / Reopen | No Violations | Capstar Drilling is moving in today . |
2051120397 | 2017-06-01 | Preliminary Restoration | No Violations | Inspected production well on 06/01/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
316554732 | 2015-7-24 0:00: | PW | No Violations | 0.50 |
744687672 | 2020-10-28 0:00 | PW | No Violations | |
873560662 | 2016-11-4 0:00: | PW | No Violations |