34-169-25560

Well Details

Well ID: 34-169-25560
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Chippewa Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: KOCSIS
License Status: Producing
License Date: 2012-06-05
Spud Date: 2007-09-27
Spud Drilling Contractor: H A D INC
Final Drill Date: 2007-10-11
Well Total Depth: 660.00 ft
Configuration: Vertical
Latitude: 40.910000
Longitude: -81.680000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-03-09 Proposed Formations:BEREA, Issued Date:3/9/2007, Expired Date:3/8/2008 6:00:00 AM, Drilling unit acres:1, Proposed Well Type:OG, Proposed Well Class:ESPW
APP 2007-05-01 Proposed Formations:BEREA, Issued Date:5/1/2007, Expired Date:4/30/2008 6:00:00 AM, Drilling unit acres:1, Proposed Well Type:OG, Proposed Well Class:ESPW
Reached Total Depth 2007-10-11
Completion Report Received 2009-01-27
APP 2012-06-05 Proposed Formations:BEREA, Issued Date:6/5/2012, Expired Date:6/5/2014 12:00:00 PM, Drilling unit acres:1, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2014-06-05
Record Last Modified 2017-02-15

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 0 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 PAC DRILLING LLC 0.00 0.00 1
2014 PAC DRILLING LLC 126.00 0.00 43
2016 PAC DRILLING LLC 105.00 0.00 290
2017 PAC DRILLING LLC 105.00 0.00 250
2018 PAC DRILLING LLC 78.00 0.00 284

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 PAC DRILLING LLC Brine 0 1
2014 PAC DRILLING LLC Brine 0 43
2016 PAC DRILLING LLC Brine 0 290
2017 PAC DRILLING LLC Brine 0 250
2018 PAC DRILLING LLC Brine 0 284

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1210288379 2011-9-9 0:00:0 PW No Violations 1.00
-124437546 2009-1-22 0:00: PL No Violations 2.70
-1377007496 2011-5-24 0:00: PW No Violations 1.00
-139097663 2013-4-10 0:00: PW No Violations 1.00
-23694235 2011-9-9 0:00:0 PW No Violations 1.00
-45259897 2011-9-9 0:00:0 PW No Violations 1.00
-587296488 2011-9-9 0:00:0 PW No Violations 1.00
-92449766 2007-10-1 0:00: DD No Violations 1.00
0023694235 2011-09-09 Production Wells Violations Noted Check to see if well has been placed into operation and found that the well head has proper ID but the tank battery for multiple wells does not. I had spoke to Jeromy Caldwell and he advised that correct ID would be posted after I notified him of the problem following my inspection 08/04/2011. Well is to have separate meter run to show well is in production .
0025946716 2012-02-22 Production Wells No Violations I checked this well today and found that there is production from two wells being recorded on the same chart. One well shows almost no production. I contacted the well owner and he stated that he does not think the well can make enough gas to stay in production and that this well will most likely be plugged in late spring.
0045259897 2011-09-09 Production Wells No Violations FOLLOW UP TO NOV # -23694235 Check to see if well has been placed into operation and found that the well head has proper ID but the tank battery for multiple wells does not. I had spoke to Jeromy Caldwell and he advised that correct ID would be posted af
0092449766 2007-10-01 Drill / Deepen / Reopen No Violations Inspect well depth and found that rig is here but nobody is around to run it.
0124437546 2009-01-22 Preliminary Restoration No Violations Had request from Columbus to check the status of this well. Also had call from operator who wanted to meet on site to review possilbe safety violations.While waiting for operator the landowner met with me and was concerned that the other well on lease have been shut in on occasion just to keep landowners from hooking up them and getting free gas.I advise that I could not get involved with any lease questions but that she should take it to an attorney.Later I met wit operator who showed me the hook up and we both felt that it was hooked up correctly. Also that he could not stop them from using it because of a safety issue. They are concerned that they would be held responsble if there was a problem.I advised him that since their company did not hook it up or show them how to hook it up they are alright.Contact Columbus and advise well is not in operation due to making too much water .Advise operator to either correct problem with well or plug it in the spring.
0139097663 2013-04-10 Production Wells No Violations Appears to still be in violation.
0333463827 2013-12-06 Production Wells No Violations This non-producing well has been issued a plugging permit, expiring in 6/2014.
0413581841 2012-01-24 Production Wells No Violations This well does not have its own meter and there is no way to find out if it is producing or being back fed pressure from another well. I had issued a compliance notice to separate the wells and meters.
0439352065 2007-09-27 Drill / Deepen / Reopen No Violations Drilling rig is over the well but there is no drilling today because there is nobody here.
0587283355 2013-04-23 Production Wells No Violations Request from Supv. Ziegler to check status of well. On last inspection, 4/10/13, well was inoperative. As of today, well has new chart however it appears to have minimal, if any production. ID signs mentioned in NOV 23694235 are in place and legible.
0587296488 2011-09-09 Production Wells No Violations FOLLOW UP TO NOV # -45259897 FOLLOW UP TO NOV # -23694235 Check to see if well has been placed into operation and found that the well head has proper ID but the tank battery for multiple wells does not. I had spoke to Jeromy Caldwell and he advised that correct ID would be posted af
0798683054 2017-07-20 Preliminary Restoration No Violations Inspected production well on 07/20/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0886629512 2012-03-05 Production Wells No Violations I checked on well production today. I could not tell if there was production or just a continuous line on the chart. Which means the well is not producing enough to meet minimum production standards of 100 MCF of natural gas or 15 BBL of oil /or a combination of both.
0925057077 2012-02-21 Production Wells No Violations My inspection found that this well does not appear to have produced today. I contacted the PAC office (330-874-3781) and left a message on their answering machine.
0934169896 2011-09-09 Production Wells No Violations Check on well status and found that well has ID. Common tank battery for multiple wells does not have any ID.
1071451447 2009-04-15 Production Wells No Violations This well was drilled and is not in production and should be plugged or placed into production.Contact Phil Caldwell and he advised that the well would be placed into production as soon as they could find the right service contractor willing to do it. It is Berea well and is shallow.
1191242361 2007-09-27 Drill / Deepen / Reopen No Violations Found that rig is over the well and that it appears to have conductor set.There is nobody around the rig today.
1199303698 2007-10-03 Drill / Deepen / Reopen No Violations Check on rig and found that they are running 7 inch casing and forgot to call me.Ran 533 ft. 7 inch casing c/w 100 sks Universal Well.
1210288379 2011-09-09 Production Wells No Violations FOLLOW UP TO NOV # -23694235 Check to see if well has been placed into operation and found that the well head has proper ID but the tank battery for multiple wells does not. I had spoke to Jeromy Caldwell and he advised that correct ID would be posted after I notified him of the problem following my inspection 08/04/2011. Well is to have separate meter run to show well is in production .
1302713244 2011-04-11 Production Wells Violations Noted This well has not been placed into production. This well must be plugged or placed into production. If you have legal proof as to why this well can not be plugged or produced , you will present that information. Your Attorney or legal staff will send the above legal files, forms or court documents showing that you can not plug or produce this well. Since this is an on going Notice of a violation this well should be plugged or placed into production within 90 days. If there are any questions please contact our Uniontown Office. 330- 896-0616
1312554680 2011-08-04 Production Wells Violations Noted Check well today to see if it is in production. I found that the well is connected in line with 2 other wells. The well has proper ID but the tank battery does not. There is no meter for the Berea well to show production . I contacted PAC Drilling and talked with Jerromy Caldwell . I advised that a separate meter needed to be connected to the Berea well to show production . It can produce into the same tank . The tank needs to have proper ID to show all wells producing into that tank.. He advised he would set a meter and update the ID on the tank.
1377007496 2011-05-24 Production Wells No Violations No work done on plug or produce notice.
1501190642 2011-04-11 Production Wells No Violations Check on well and found that it is idle still. Issue NOV to plug or produce.
1579321556 2018-11-05 Production Wells No Violations Inspected production well on 11/05/2018. The tank battery consists of 1-100 bbl steel tank and 1-horizontal separator with a meter box, located within a partial earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a swedge to the surface casing, elbow, and flowline. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1696994959 2009-06-24 Production Wells No Violations Well remains idle , no work done on producing well.
1737550895 2012-03-13 Production Wells No Violations I checked this well production chart. The line on the production chart has not moved enough to show any visible production.
1884800131 2016-03-21 Production Wells No Violations Inspected production well on 03/21/2016. The tank battery consists of 1-100 bbl steel tank and 1-horizontal separator located within an earthen dike. The dike needs built-up on the backside in order to effectively serve as containment. Gus with PAC Drilling was notified of this issue and will have it addressed promptly. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a swedge-top wellhead with flowline. Well identification is posted at the wellhead as required. No other problems were noted at the time of the inspection.
2018877313 2017-07-20 Production Wells No Violations nspected production well on 07/20/2017. The tank battery consists of 1-100 bbl steel tank and 1-horizontal separator equipped with a meter box, located within a shallow earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a swedge with an elbow and flowline. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
25946716 2012-2-22 0:00: PW No Violations 1.00
333463827 2013-12-6 0:00: PW No Violations 0.50
413581841 2012-1-24 0:00: PW No Violations 1.00
439352065 2007-9-27 0:00: DD No Violations 1.50
587283355 2013-4-23 0:00: PW No Violations 1.00
798683054 2017-7-20 0:00: PL No Violations
886629512 2012-3-5 0:00:0 PW No Violations 1.00
925057077 2012-2-21 0:00: PW No Violations 1.00
934169896 2011-9-9 0:00:0 PW No Violations 1.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0023694235 US-OH-122276 2011-09-12 Failure to legibly identify well
1302713244 US-OH-108538 2011-04-13 Failure to legibly identify well
1302713244 US-OH-108539 2011-04-13 Defective casing, leaking well
1312554680 US-OH-108865 2011-08-05 Failure to legibly identify well

For data sources see[8]

References