Well Details

Well ID: 34-169-25617
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Salt Creek Township
Operator Name: INDUSTRY STANDARD SUPPLIES INC
Well Pad ID:
Farm/Lease Name: COBLENTZ UNIT
License Status: Producing
License Date: 2008-09-16
Spud Date: 2008-10-18
Spud Drilling Contractor: WHIPSTOCK OHIO DRILLING
Final Drill Date: 2008-10-22
Well Total Depth: 3707.00 ft
Configuration: Vertical
Latitude: 40.660000
Longitude: -81.870000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-09-16 Proposed Formations:CLINTON, Issued Date:9/16/2008, Expired Date:9/16/2009 6:00:00 AM, Drilling unit acres:25, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-10-22
Completion Report Received 2009-04-16
Construction Permit Expires 2009-09-16
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-29 3486 3544 53
3486 3544 53
3486 3544 53

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 FRAC VOLUMES NOT REPORTED

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 INDUSTRY STANDARD SUPPLIES INC 6994.00 0.00 306
2010 INDUSTRY STANDARD SUPPLIES INC 3941.00 0.00 365
2011 INDUSTRY STANDARD SUPPLIES INC 2027.00 19.00 365
2012 INDUSTRY STANDARD SUPPLIES INC 917.00 0.00 366
2013 INDUSTRY STANDARD SUPPLIES INC 56.00 0.00 365
2014 INDUSTRY STANDARD SUPPLIES INC 97.00 0.00 365
2015 INDUSTRY STANDARD SUPPLIES INC 86.00 0.00 365
2016 INDUSTRY STANDARD SUPPLIES INC 101.00 0.00 365
2017 INDUSTRY STANDARD SUPPLIES INC 69.00 0.00 365
2018 INDUSTRY STANDARD SUPPLIES INC 74.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 INDUSTRY STANDARD SUPPLIES INC Brine 0 306
2010 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2011 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2012 INDUSTRY STANDARD SUPPLIES INC Brine 0 366
2013 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2014 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2015 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2016 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2017 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2018 INDUSTRY STANDARD SUPPLIES INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1127562791 2020-10-28 0:00 PW No Violations
-1185336779 2017-12-4 0:00: PL No Violations
-1288842134 2008-10-23 0:00 DD No Violations 1.50
-1501833421 2008-10-20 0:00 DD No Violations 1.50
-1545214128 2009-3-25 0:00: PL No Violations 1.00
-1765668576 2008-10-15 0:00 DD No Violations 2.50
-2104922236 2017-12-4 0:00: PW No Violations
-212730486 2018-8-9 0:00:0 PW No Violations
-935455430 2008-10-17 0:00 DD No Violations 5.50
0212730486 2018-08-09 Production Wells No Violations Inspected production well on 08/09/2018. The tank battery consists of 2-100 bbl steel tanks, 1-50 bbl steel tank, 2-vertical separators, 2-drips, and 2-meter boxes, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is a rabbit well. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
0935455430 2008-10-17 Drill / Deepen / Reopen No Violations Arrive to dig another test hole.Will dig entire pit today if we do not find water too soon.W/o equipment.Dig first pit and then had to wait for rig to spot equipment and then dig 2 nd pit.Haul in clay to fill pits and then line with reinforced state approved liners.
0981789498 2008-11-04 Drill / Deepen / Reopen No Violations ChemTech has another truck on site and used full load and blow pit is now firm and can be closed.
0987001975 2013-01-07 Production Wells No Violations This is a producing plunger lift well. There were no problems noted at the time of the inspection.
1185336779 2017-12-04 Preliminary Restoration No Violations Inspected production well on 12/04/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes.
1232998176 2008-11-03 Drill / Deepen / Reopen No Violations Solidify pits in floodplain area today with ChemTech.They sent two trucks.Start out on Working pit first and then close.Switch to blow pit and needed second load to firm it up .After 2nd load was done I advised leave open until morning and then after inspection it can be closed.
1288842134 2008-10-23 Drill / Deepen / Reopen No Violations Check on rig and found that they have moved.Pit level and liners are good.Pit needs to be pumped off and solidified and closed.
1491511984 2014-02-13 Production Wells No Violations This is a producing lift well. No apparent problems at this time.
1501833421 2008-10-20 Drill / Deepen / Reopen No Violations Whipstock Drilling set 384 ft. of 8 5/8 casing c/w 125 sks.Universal Well.Rig is at 404 ft dusting on 7 7/8 hole.
1545214128 2009-03-25 Preliminary Restoration No Violations Meets requirements for Primary Restoration .
1595370488 2008-11-07 Drill / Deepen / Reopen No Violations Pits have been closed and area graded.Needs re-seeded and vegetation established before Primary can be passed.
1765668576 2008-10-15 Drill / Deepen / Reopen No Violations W/o equipment and operator to arrive for test hole.During test found water at a depth which would not work for earthen pits.Contact Tim and advise.Had return call from Tim and he told me we dug in the wrong location and wanted to retest .Set test up for Thursday
2104922236 2017-12-04 Production Wells No Violations Inspected production well on 12/04/2017. The tank battery consists of 2-100 bbl steel tanks, 1-50 bbl steel tank, 2-vertical separators, 2-drips, and 2-meter boxes, located within a shallow earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is a rabbit well. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
981789498 2008-11-4 0:00: DD No Violations 2.00
987001975 2013-1-7 0:00:0 PW No Violations

For data sources see[9]