If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-60415 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.94,"lon":-81.68,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Chippewa Township | |
Operator Name: DOMINION EAST OHIO | |
Well Pad ID: | |
Farm/Lease Name: HUFFMAN DANIEL HEIRS | |
License Status: Storage Well | |
License Date: 1919-08-18 | |
Spud Date: 1900-01-01 | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 40.940000 | |
Longitude: -81.680000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Record Last Modified | 2009-12-11 | STORAGE- |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2002 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2003 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2004 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2005 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2006 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2007 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2008 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2002 | DOMINION EAST OHIO | Brine | 0 | 0 |
2003 | DOMINION EAST OHIO | Brine | 0 | 0 |
2004 | DOMINION EAST OHIO | Brine | 0 | 0 |
2005 | DOMINION EAST OHIO | Brine | 0 | 0 |
2006 | DOMINION EAST OHIO | Brine | 0 | 0 |
2007 | DOMINION EAST OHIO | Brine | 0 | 0 |
2008 | DOMINION EAST OHIO | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1524680863 | 2014-3-3 0:00:0 | SO | No Violations | 0.50 |
-539449320 | 2018-1-10 0:00: | SO | No Violations | |
0539449320 | 2018-01-10 | Storage Well | No Violations | Performed annual inspection for Dominion East Ohio Storage Well #0563 on 01/10/2018. The well is equipped with a flanged wellhead with 1-master valve and 2-wing valves, 1-vertical separator, and 1-100 bbl steel tank located within an earthen dike. Well identification is clearly displayed. The well is located ~150 from its RBDMS location. No other problems were noted at the time of the inspection. |
0595308072 | 2016-01-13 | Storage Well | No Violations | Inspected Dominion East Ohio Storage Well #563 on 01/13/2016. The tank battery consists of 1-100 bbl steel tank located within an earthen dike; 1-vertical separator is located nearby. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve. No problems were noted at the time of the inspection. |
0878289032 | 2017-01-09 | Storage Well | No Violations | Performed annual inspection for Dominion East Ohios Storage Well #0563 on 01/09/2017. The well is equipped with a flanged wellhead with 1-master valve and 2-wing valves, 1-vertical separator, and 2-100 bbl steel tanks, located within an earthen dike. Well identification is clearly displayed. A very small amount of fluid was noted in the snow around the front tank (within the earthen dike), with its source appearing to be from the top of the tank. Phil Zbasnik with Dominion East Ohio was notified of this issue and sent field staff to address it and make the repairs immediately (a line at the top of the tank was found to have broken - it was replaced). The well is located ~150 from its RBDMS location. No other problems were noted at the time of the inspection. |
1163009577 | 2015-01-29 | Storage Well | No Violations | This gas storage well has no apparent problems at this time. |
1184315030 | 2020-1-13 0:00: | SO | No Violations | |
1524680863 | 2014-03-03 | Storage Well | No Violations | This gas storage well has no apparent problems at time of inspection. |
1548765576 | 2019-01-25 | Storage Well | No Violations | Performed annual inspection for Dominion East Ohio Storage Well #0563 on 01/25/2019. The well is equipped with a flanged wellhead with 1-master valve and 2-wing valves, 1-vertical separator, and 1-100 bbl steel tank located within an earthen dike. Well identification is clearly displayed. A locked security chain around the master valve and one wing valve was present at the time of the inspection. The well is not located in its RBDMS location. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Aaron Lantz (DOGRM Columbus). No other problems were noted at the time of the inspection. |
1736605736 | 2013-03-25 | Storage Well | No Violations | I inspected Dominion East Ohio Gas storage well # 563 today. The well is located in Section 23, Chippewa Township, Wayne County, Ohio. The well is equipped with a master gate valve, and a side gate valve with a 4.00 Daniels run plumbed into the main pipeline. There are two (2) storage tanks on this well, along with a vertical separator. There is a flow gate with a 3.00 line plumbed into the first storage tank. There is a 3.00 line plumbed from the first storage tank, to the vertical separator with a 3.00 line returning into the second storage tank from the vertical separator. There are two (2) pickup lines on the first tank and one pickup line on the second tank. All lids and hatches on both tanks are closed and secure and the pickup lines on both tanks are secured with valves and bullhead plugs in place. There is a dike around the storage tanks and it is of sufficient size to meet the requirements of 1501-9-9-05. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. No violations found. |
595308072 | 2016-1-13 0:00: | SO | No Violations | |
878289032 | 2017-1-9 0:00:0 | SO | No Violations |
For data sources see[7]