Well Details

Well ID: 37-003-00926
Loading map...
Country: United States
State: Pennsylvania
County: Allegheny
Municipality: Forward Township
Operator Name: EQUITRANS LP
Well Pad ID:
Farm/Lease Name: M.P. IRWIN
License Status: Plugged and Abandoned
Spud Date:
Permit Date:
Well Type: STORAGE WELL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.216393
Longitude: -79.862098

For data sources see[1][2][3]

Well History

Date Event
1942-01-01 Drilling Completion
1942-01-01 NEWLY DRILLED
2018-10-10 Begin Plugging
2018-10-19 Finished Plugging
2020-01-02 Fully Plugged

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2002 CONSOL GAS CO 0.00 0 0.00 0 0.00 0
2004 0.00 0 0.00 0 0.00 0
2005 0.00 0 0.00 0 0.00 0
2006 0.00 0 0.00 0 0.00 0
2010 0.00 0 0.00 0 0.00 0
2011 0.00 0 0.00 0 0.00 0
2012 0.00 0 0.00 0 0.00 0
2013 0.00 0 0.00 0 0.00 0
2014 EQUITRANS LP 0.00 0 0.00 0 0.00 0
2015 EQUITRANS LP 0.00 0 0.00 0 0.00 0
2016 EQUITRANS LP 0.00 0 0.00 0 0.00 0
2017 EQUITRANS LP 0.00 0 0.00 0 0.00 0
2018 EQUITRANS LP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 Produced Fluid 2.06 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE OH0987034667
2012 Produced Fluid 5.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE OH0987034667
2013 Produced Fluid 0.50 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1718221 Primary Facility 2008-06-17 Routine/Complete Inspection No Violations Noted observation
1916315 Primary Facility 2009-08-03 Routine/Complete Inspection No Violations Noted
2036284 Primary Facility 2012-01-19 Routine/Complete Inspection No Violations Noted Observation well in GambleHayden reservoir;643psig; not in line; annulus open
2119122 Primary Facility 2012-11-28 Routine/Complete Inspection No Violations Noted Observation well in PNG Gamble Hayden; Valves good; annulus open; need better access 100 feet to location; 645 psig;
218995 Primary Facility 1995-05-14 Routine/Complete Inspection No Violations Noted 630 PSI/ANN OPEN
219101 Primary Facility 1997-04-29 Routine/Complete Inspection No Violations Noted 630 PSI/ANN OPEN
220568 Primary Facility 1998-06-11 Routine/Complete Inspection No Violations Noted 640 PSI; ANN OPEN
221662 Primary Facility 1999-05-18 Routine/Complete Inspection No Violations Noted 600 PSI; ANN OPEN
2226631 Primary Facility 2013-11-26 Routine/Complete Inspection No Violations Noted Observation well in PNG Gamble Hayden reservoir; 650 psig; open annulus; wellhead ok;
2330800 Primary Facility 2014-12-22 Routine/Complete Inspection No Violations Noted 647 psig; withdrawing; no issues;
2429584 Primary Facility 2015-11-05 Routine/Complete Inspection No Violations Noted 648 psig; observation well; valve ok;
2514914 Primary Facility 2016-08-18 Routine/Complete Inspection No Violations Noted Observation well; 650 psig; no issues; not connected; open annulus; injecting in field;
2784375 Primary Facility 2018-10-04 Plugging(Includes Plugged/Mined Through) No Violations Noted Viking Well Service Rig is just setting up to begin plugging this well.
2786450 Primary Facility 2018-10-10 Plugging(Includes Plugged/Mined Through) No Violations Noted Equitrans is setting a bottom hole plug at 1628' to shut off gas from the Big Injun Sand. After the plug is set they will run a bond log in the 7"casing.
2790856 Primary Facility 2018-10-18 Plugging(Includes Plugged/Mined Through) No Violations Noted This well is cemented solid from 1,628' up to 1,511'. From 1,511' the 7" casing is being perfed or jet cut every 50'. At this time they have been unable to pull the7".

For data sources see[7]