Well Details

Well ID: 37-003-22092
Loading map...
Country: United States
State: Pennsylvania
County: Allegheny
Municipality: Fawn Township
Operator Name: XTO ENERGY INC
Well Pad ID: 149695
Farm/Lease Name: FAWN DEVELOPERS INC 4H
License Status:
Spud Date:
Permit Date: 2009-09-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.648704
Longitude: -79.777674

For data sources see[1][2][3]

Well History

Date Event
2009-09-28 New Permit Application
2009-12-03 Performed Spud Operation
2010-01-17 Drilling Completion
2010-04-13 Perforation
2010-07-08 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 PHILLIPS EXPLORATION INC 653,479.00 218 0.00 34 0.00 0
2011 PHILLIPS EXPLORATION INC 671,431.00 362 0.00 0 0.00 0
2012 XTO ENERGY INC 425,511.00 366 0.00 0 0.00 0
2013 XTO ENERGY INC 315,499.00 365 0.00 0 0.00 0
2014 XTO ENERGY INC 262,820.00 349 0.00 0 0.00 0
2015 XTO ENERGY INC 212,210.00 355 0.00 0 0.00 0
2016 XTO ENERGY INC 40,860.00 73 0.00 0 0.00 0
2017 XTO ENERGY INC 175,873.60 217 0.00 0 0.00 0
2018 XTO ENERGY INC 188,222.00 353 0.00 0 0.00 0
2019 XTO ENERGY INC 154,247.00 361 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 PHILLIPS EXPLORATION INC Produced Fluid 7,901.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2011 PHILLIPS EXPLORATION INC Produced Fluid 2,194.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2011 PHILLIPS EXPLORATION INC Produced Fluid 1,770.00 Bbl INJECTION DISPOSAL WELL 34-059-24067
2011 PHILLIPS EXPLORATION INC Produced Fluid 119.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-133-20114
2011 PHILLIPS EXPLORATION INC Produced Fluid 965.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2011 PHILLIPS EXPLORATION INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2012 XTO ENERGY INC Produced Fluid 503.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2012 XTO ENERGY INC Produced Fluid 225.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 XTO ENERGY INC Produced Fluid 3,079.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674
2012 XTO ENERGY INC Produced Fluid 189.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2012 XTO ENERGY INC Produced Fluid 114.00 Bbl INJECTION DISPOSAL WELL 34-059-24067
2012 XTO ENERGY INC Produced Fluid 119.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2013 XTO ENERGY INC Produced Fluid 108.00 Bbl INJECTION DISPOSAL WELL 34-059-24067
2013 XTO ENERGY INC Produced Fluid 678.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674
2013 XTO ENERGY INC Produced Fluid 186.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 XTO ENERGY INC Produced Fluid 164.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2013 XTO ENERGY INC Produced Fluid 406.00 Bbl CENT WASTE TRT FAC NPDES PA0254185
2013 XTO ENERGY INC Produced Fluid 392.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 101674
2013 XTO ENERGY INC Produced Fluid 406.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0254185
2014 XTO ENERGY INC Produced Fluid 1,253.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2014 XTO ENERGY INC Produced Fluid 50.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2014 XTO ENERGY INC Produced Fluid 116.00 Bbl CENT WASTE TRT FAC NPDES PA0254185
2014 XTO ENERGY INC Produced Fluid 116.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0254185
2015 XTO ENERGY INC Produced Fluid 1,081.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2015 XTO ENERGY INC Produced Fluid 45.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 XTO ENERGY INC Produced Fluid 250.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2016 XTO ENERGY INC Produced Fluid 7.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 XTO ENERGY INC Servicing Fluid 330.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 XTO ENERGY INC Other Oil & Gas Wastes 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 XTO ENERGY INC 1,275.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 XTO ENERGY INC Produced Fluid 1,535.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 XTO ENERGY INC Produced Fluid 1,141.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 XTO ENERGY INC Servicing Fluid 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 XTO ENERGY INC Produced Fluid 134.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2019 XTO ENERGY INC Produced Fluid 187.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2019 XTO ENERGY INC Produced Fluid 604.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1851500 Primary Facility 2009-12-02 Drilling/Alteration No Violations Noted SITE BUILT NO RIG.
1851527 Primary Facility 2009-12-14 Drilling/Alteration No Violations Noted MARCELLUS TOP HOLE COMPLETE @ 6000'
1851531 Primary Facility 2009-12-08 Drilling/Alteration No Violations Noted PHILLIPS 6 DRILLING AT 1650'
1864339 Primary Facility 2010-01-05 Drilling/Alteration No Violations Noted DRILLING @ 6300'. SITE, PIT, E&S, & ACCESS, OK.
1865495 Primary Facility 2010-01-20 Drilling/Alteration No Violations Noted SAXON RIG 124 MOVING TO 3H.
1865639 Primary Facility 2010-02-24 Drilling/Alteration No Violations Noted DRILLING COMPLETE. SAXON 124 MOVING FROM SITE. WELL HEAD EQUIPTMENT INSTALLED.
1865643 Primary Facility 2010-02-24 Drilling/Alteration No Violations Noted DRILLING COMPLETE. WELLHEAD EQUIPTMENT INSTALLED. FRACK PIT FULL WITH FRESH WATER.
1879882 Primary Facility 2010-04-22 Routine/Complete Inspection No Violations Noted On April 22, 2010 I visited this site for a routine inspection. Drilling had been completed and the well was being flared off. A site ID sign and E&S plan were posted on site. The access road was in good condition. The E&S controls were in place according to the plan on site. The pits appeared to be in good condition. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is fully restored.
1882740 Primary Facility 2010-04-05 Drilling/Alteration No Violations Noted THIS MARCELLUS WELL IS READY TO FRAC. SITE, PIT, E&S, AND ACCESS OK.
1894370 Primary Facility 2010-06-23 Routine/Complete Inspection No Violations Noted On June 23, 2010 I visited this site for a routine inspection. Drilling had been completed and work was commencing on the production units. A site ID sign and E&S plan were posted on site. The access road was in good condition. The E&S controls were in place according to the plan on site. The pits appeared to be in good condition. Portions of the silt fence surrounding the impoundments were beginning to become overtaken. These should be addressed immediately. The operator should continue to inspect and maintain the E&S controls routinely and after each runoff event until the site is fully restored.
1894790 Primary Facility 2010-05-03 Drilling/Alteration No Violations Noted marcellus horizontal, fraced, in line
1904661 Primary Facility 2010-07-21 Routine/Complete Inspection No Violations Noted On July 21st, 2010 I visited this site for a routine inspection. Drilling had been completed and work was being completed on the production units and security fence was being installed. A site ID sign and E&S plan were posted on site. The access road was in good condition. The E&S controls were in place according to the plan on site. The pits were being drained at the time of my inspection. The operator should continue to inspect and maintain the E&S controls routinely and after each runoff event until the site is fully restored.
1913796 Primary Facility 2010-09-02 Routine/Complete Inspection No Violations Noted On September 2nd, 2010 I visited this site for a routine inspection. Drilling had been completed. A site ID sign and E&S plan were posted on site. The access road was in good condition. The E&S controls were in place according to the plan on site. The pits were emptied. Repairs had been made to the silt fence that were noted in the 7/21/10 inspection. The operator should continue to inspect and maintain the E&S controls routinely and after each runoff event until the site is fully restored.
1930591 Primary Facility 2010-11-10 Drilling/Alteration No Violations Noted WELL IS PROTECTED BY A FENCE. HEATERS AND TANKS ARE ALSO FENCED. RESTORATION IN PROGRESS.
1940452 Primary Facility 2010-12-28 Routine/Complete Inspection No Violations Noted On December 28th, 2010 I visited this site for a routine inspection. Drilling had been completed. The well was in production. A site ID sign and E&S plan were posted on site. The access road was in good condition. The E&S controls were in place according to the plan on site. The pits were closed and the site was graded. The area around the well head was being rocked. The operator should continue to inspect and maintain the E&S controls routinely and after each runoff event until the site is fully restored.
1993489 Primary Facility 2011-07-26 Routine/Complete Inspection No Violations Noted On July 26th, 2011 I visited this site for a routine inspection. Drilling had been completed. The well was in production. A well tag was present. The access road was in good condition. The site was graded, seeded , and mulched. Growth was sparse in some areas however. 6 tanks were surrounded by a dike. No spills, leaks, or accelerated erosion were observed during the inspection.
2102491 Primary Facility 2012-09-25 Routine/Complete Inspection No Violations Noted John Ley , WQS, SWRO was on site to conduct a routine inspection. There was a security gate located at the entrance to the access road and fencing surrounding the well pad. At the time of the inspection, the well sign and inspections copies were on site. Hillsides were stabilized and had good growth on them. No accelerated erosion or sedimentation issues were observed on site.
2728897 Primary Facility 2018-05-11 Routine/Complete Inspection No Violations Noted Multi-well pad. At time of Inspection, both wells drilled and appear equipped for production.