Well ID: 37-003-22131 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.359444,"lon":-79.802861,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Allegheny | |
Municipality: White Oak Borough | |
Operator Name: DAKOTA OIL & GAS CO | |
Well Pad ID: | |
Farm/Lease Name: GLUMAC | |
License Status: Plugged and Abandoned | |
Spud Date: 2010-11-03 | |
Permit Date: 2010-09-22 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.359444 | |
Longitude: -79.802861 |
Date | Event |
---|---|
2010-09-22 | New Permit Application |
2010-11-03 | Performed Spud Operation |
2010-11-15 | Drilling Completion |
2012-02-01 | NEWLY DRILLED |
2016-12-06 | Begin Plugging |
2016-12-07 | Finished Plugging |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | PENNECO OIL CO INC | 141.00 | 31 | 0.00 | 0 | 0.00 | 0 |
2011 | PENNECO OIL CO INC | 15,473.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | PENNECO OIL CO INC | 12,312.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | PENNECO OIL CO INC | 738.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | PENNECO OIL CO INC | 106.00 | 274 | 0.00 | 0 | 0.00 | 0 |
2015 | DAKOTA OIL & GAS CO | 102.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | DAKOTA OIL & GAS CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | PENNECO OIL CO INC | Drilling Fluid Waste | 4,730.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2013 | PENNECO OIL CO INC | Produced Fluid | 33 Bbl | CENT WASTE TRT FAC NPDES | PA0095443 |
2013 | PENNECO OIL CO INC | Produced Fluid | 33.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095443 |
2016 | DAKOTA OIL & GAS CO | Produced Fluid | 127.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095443 |
2016 | DAKOTA OIL & GAS CO | Produced Fluid | 127 Bbl | CENT WASTE TRT FAC NPDES | PA0095443 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1930553 | Primary Facility | 2010-11-03 | Drilling/Alteration | No Violations Noted | SITE IS BUILT. NO RIG. NO LINER IN PIT. PIT IS PROTECTED BY A CHAIN LINK FENCE. E&S, AND ACCESS, OK. |
1930556 | Primary Facility | 2010-11-04 | Drilling/Alteration | No Violations Noted | USE RIG 5. RIG DOWN FOR MEINTENANCE. DEPTH 335'. |
1930574 | Primary Facility | 2010-11-08 | Drilling/Alteration | No Violations Noted | USE RIG 5 @ 690'.HOME OWNER NEXT TO PAD SAID HIS WATER HAS TURNED BROWN. CONTRACTOR IS HOOKING UP A WATER BUFFALO TO TWO EFFECTED HOMES. |
1931207 | Primary Facility | 2010-11-12 | Complaint Inspection | No Violations Noted | On November 12th, 2010 I conducted an inspection of the above site in response to a water supply complaint. Drilling was taking place. The access road was in good condition. A Site ID and E&S Plan were posted on site. E&S controls were in place according to the plan. There was no evidence of spills or leaks and no accelerated erosion was observed at the time of the inspection. Drinking water samples were collected from the well at the complainant¿s residence. |
1933536 | Primary Facility | 2010-12-01 | Routine/Complete Inspection | No Violations Noted | On Decmber 1st, 2010 I conducted a routine inspection of the above site. Drilling was completed. The well was not yet in production. The access road was in good condition. A Site ID and E&S Plan were posted on site. E&S controls were in place according to the plan. The drilling pits were closed. There was no evidence of spills or leaks and no accelerated erosion was observed at the time of the inspection. |
1939734 | Primary Facility | 2010-12-14 | Routine/Complete Inspection | No Violations Noted | On Decmber 14th, 2010 I conducted a routine inspection of the above site. Drilling was completed. The well was not yet in production. The access road was in good condition. A Site ID and E&S Plan were posted on site. E&S controls were in place according to the plan. The drilling pits were closed. The site was rough graded. A crew was on site installing the pipeline. There was no evidence of spills or leaks and no accelerated erosion was observed at the time of the inspection. The operator was contacted to submit a schedule and plan for replacing the water supply impacted at 201 Will Court Rd, |
1957796 | Primary Facility | 2011-02-01 | Complaint Inspection | No Violations Noted | On February 1st, 2011 I visited this site in response to the water supply investigation at 201 Will Court Rd. Drilling operations were completed. The water suppply was first impacted on 11/04/2010. Peneco representatives were onsite and water samples were split between Penneco and DEP. Results of the samples will determine what further actions the operator will need to take to replace or repair the water supply. |
1961853 | Primary Facility | 2011-03-08 | Complaint Inspection | No Violations Noted | On March 8th, 2011 I visited this site in response to the water supply investigation at 201 Will Court Rd. Drilling operations were completed. The water suppply was first impacted on 11/04/2010. Peneco representatives were onsite and water samples were split between Penneco and DEP. Results of the samples will determine what further actions the operator will need to take to replace or repair the water supply. |
2027549 | Primary Facility | 2011-12-15 | Complaint Inspection | No Violations Noted | Split sample with consultant. Awaiting results. |
2077185 | Primary Facility | 2012-06-19 | Routine/Complete Inspection | No Violations Noted | 06-19-2012 This was a follow up inspection to the orginal complaint #275486. John Ley, WQS SWRO met with Jim and Linda Wetzler at their house. A meeting with the Wetzlers, Penneco and the Department was going to be held on 06-20-2012. This meeting was held to give the Wetzlers a chance to document their concerns. |
2081918 | Primary Facility | 2012-07-10 | Routine/Complete Inspection | No Violations Noted | John Ley WQS and John Carson WQS SWRO were on site to conduct a split water sample with the Penneco vendor. Samples were collected and shipped for analysis. |
2109086 | Primary Facility | 2012-10-18 | Routine/Complete Inspection | No Violations Noted | John Ley WQS SWRO was on site to conduct a split water sample with the Penneco vendor. Samples were collected and shipped to the lab for analysis. |
2115422 | Primary Facility | 2012-11-14 | Complaint Inspection | No Violations Noted | John Ley WQS SWRO was on site to conduct a split water sample with the Penneco vendor. Samples were collected and shipped to the lab for analysis. A copy of the water test results from the 10-18-12 split sample was handed to the Mrs. Wetzler while on site today. |
2124677 | Primary Facility | 2012-12-19 | Routine/Complete Inspection | No Violations Noted | John Ley WQS SWRO was on site to conduct a split water sample with the Penneco vendor. Samples were collected and shipped to the lab for analysis. A copy of the Department's water test results from the 11-14-12 sample was handed to the Mrs. Wetzler while on site today. The Glumac #1 well was inspected while on site. No violations were apparent. |
2153483 | Primary Facility | 2013-03-21 | Follow-up Inspection | No Violations Noted | Split a sample with Penneco of the Wetzler's drinking water. Examined and documented work on the drinking water system. |
For data sources see[7]