37-005-22166

Well Details

Well ID: 37-005-22166
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Plumcreek Township
Operator Name: PETRO SVC PARTNERS INC
Well Pad ID:
Farm/Lease Name: ROY KAUFMAN 1
License Status: ACTIVE
Spud Date:
Permit Date: 1978-06-05
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.712412
Longitude: -79.348316

For data sources see[1][2][3]

Well History

Date Event
1978-06-05 New Permit Application
1978-09-09 Performed Spud Operation
1978-09-13 Drilling Completion
1978-10-20 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1991 PETRO SVC PARTNERS INC 3942.00 365 0.00 0 0.00 0
1996 CASTLE GAS CO INC 1745 186 0.00 0 0.00 0
1997 CASTLE GAS CO INC 1593 365 0.00 0 0.00 0
1998 CASTLE GAS CO INC 2707 365 0.00 0 0.00 0
1999 CASTLE GAS CO INC 3500 365 0.00 0 0.00 0
2000 CASTLE GAS CO INC 2786 365 0.00 0 0.00 0
2001 PETRO SVC PARTNERS INC 3060 364 0.00 0 0.00 0
2002 PETRO SVC PARTNERS INC 3656 365 0.00 0 0.00 0
2003 PETRO SVC PARTNERS INC 3598 365 0.00 0 0.00 0
2004 3502 366 0.00 0 0.00 0
2005 2836 365 0.00 0 0.00 0
2006 2458.00 360 0.00 0 0.00 0
2007 2329.00 365 0.00 0 0.00 0
2008 5106.00 366 0.00 0 0.00 0
2009 3740.00 365 0.00 0 0.00 0
2010 3,649.00 365 0.00 0 0.00 0
2011 3,158.00 353 0.00 0 0.00 0
2012 2,855.00 355 0.00 0 0.00 0
2018 PETRO SVC PARTNERS INC 2,531.00 275 0.00 0 0.00 0
2019 PETRO SVC PARTNERS INC 4,093.00 350 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2000 CASTLE GAS CO INC Brine 95.00 Bbl Brine or Industrial Waste Treatment Plt

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2465009 Primary Facility 2016-03-14 Routine/Complete Inspection Violation(s) Noted Well tagged-shut in. Annulus open-venting excessive-hazardous amount of gas into atmosphere with occupied residence 145' away. Well head needs some work to protect mechanical integrity. 50 bbl tank completely rusted away-still plumbed to well.
2465027 Primary Facility 2016-03-16 Follow-up Inspection No Violations Noted Met with emergency contractor Applachian Services to inspect the installation of a 2"x11' vertical vent with rain cap on the annulus of this well to vent and disperse gas higher into the atmosphere. This was done for immediate public safety until responsible party can be located to mitigate venting of gas in a more permanent manner.
2685168 Primary Facility 2018-01-12 Compliance Evaluation Outstanding Violations - Viols Req'd This well is not tagged and is shut in in failure to plug an abandoned well status. The well head casing is corroded and the annulus is venting an excessive amount of gas to the atmosphere in a manner that presents a hazard to the public. The 50 bbl steel fluid collection tank is completely rusted and corroded apart and need removed. No annual mechanical integrity report or annual production reports have been submitted for this well.
2754916 Primary Facility 2018-07-23 Follow-up Inspection Outstanding Violations - Viols Req'd This well still has an emergency vertical vent pipe plumbed 10' up into the air to vent leaking annular gas up into the atmosphere. This well is leaking a greater volume of gas now than it was during my last inspection and constitutes a higher degree of hazard to the health and safety of the public. The well is still untagged, shut in and venting leaking annular gas badly from defective casing somewhere down hole which was not reported. This well is still classified as a failure to plug an abandoned well with no mechanical integrity or annual production reports having been submitted annually as required by law. There is still a badly rusted 50 bbl steel tank sitting on site plumbed to the well which is so full of holes and rusted jagged edges of sharp metal as to constitute a hazard to domestic pasture animals and children who frequent this area which is near a home.
2759354 Primary Facility 2018-08-02 Follow-up Inspection Outstanding Violations - Viols Req'd On this date, the new operator extinguished the flare and plumbed two pressure recorders to the well in order to monitor the leaking annular space and the shut in 4 1/2" casing. The pressure recorders have both been calibrated and the operator gave me the calibration paperwork. I witnessed the installation of and pressurization of the recorders. The annulus space recorder had 2 psi on it and the 4 1/2" production casing recorder had 420 psi on it. The operator is going to monitor these recorders for 7 days to assess the mechanical integrity of the well and will furnish daily reports and take the appropriate steps to restore this well to production and maintain the mechanical integrity of the well. The operator plans to remove all equipment not necessary for production including the old rusted out 50 bbl steel fluid collection tank and the operator plans to pressure test the integrity of the sales line before returning this well to production.
2760510 Primary Facility 2018-08-06 Follow-up Inspection Outstanding Violations - Viols Req'd On this date a check of the pressure recorders indicated that the 4 1/2" production casing recorder was reading 425 psi and the annulus recorder was reading 1.5 psi.
2760846 Primary Facility 2018-08-07 Follow-up Inspection Outstanding Violations - Viols Req'd On this date a check of the pressure recorders indicated that the 4 1/2" production casing recorder was reading 420 psi and the annulus recorder was reading 1.5 psi. I conducted a gas check sweep of the surface area surrounding the well and checked the sub- surface in several openings and holes surrounding the well. I also sampled the air around the well including down wind from the well. All readings on my Altair 5 X meter remained at non-detect for the presence of gas. And I also used a Gas Trac sniffer to sample the ground and air around the well and the sampling came back at non-detect for the presence of any gas.
2823544 Primary Facility 2019-01-08 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus pressure is being monitored and is good. The well head casing and piping look ok.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2465009 754356 2016-03-14 2018-12-26 78.74 Environmental Health & Safety
2685168 807640 2018-01-12 OGA3211(H) Administrative
2685168 807641 2018-01-12 78a74 Environmental Health & Safety
2685168 807642 2018-01-12 78a88(d) Environmental Health & Safety
2685168 807643 2018-01-12 78.121(A) Administrative
2685168 807644 2018-01-12 78.88(b)1 Environmental Health & Safety
2685168 807645 2018-01-12 78.88(d) Environmental Health & Safety
2685168 807646 2018-01-12 78.91(a) Environmental Health & Safety
2754916 824602 2018-07-23 OGA3211(H) Administrative
2754916 824603 2018-07-23 78.74 Environmental Health & Safety
2754916 824604 2018-07-23 78a88(d) Environmental Health & Safety
2754916 824605 2018-07-23 78.121(A) Administrative
2754916 824606 2018-07-23 78.91(a) Environmental Health & Safety
2754916 824607 2018-07-23 78.88(d) Environmental Health & Safety
2759354 824167 2018-07-23 OGA3211(H) Administrative
2759354 824168 2018-07-23 78.74 Environmental Health & Safety
2759354 824169 2018-07-23 78a88(d) Environmental Health & Safety
2759354 824170 2018-07-23 78.121(A) Administrative
2759354 824171 2018-07-23 78.91(a) Environmental Health & Safety
2759354 824172 2018-07-23 78.88(d) Environmental Health & Safety
2760510 824406 2018-07-23 OGA3211(H) Administrative
2760510 824407 2018-07-23 78.74 Environmental Health & Safety
2760510 824408 2018-07-23 78a88(d) Environmental Health & Safety
2760510 824409 2018-07-23 78.121(A) Administrative
2760510 824410 2018-07-23 78.91(a) Environmental Health & Safety
2760510 824411 2018-07-23 78.88(d) Environmental Health & Safety
2760846 824501 2018-07-23 OGA3211(H) Administrative
2760846 824502 2018-07-23 78.74 Environmental Health & Safety
2760846 824503 2018-07-23 78a88(d) Environmental Health & Safety
2760846 824504 2018-07-23 78.121(A) Administrative
2760846 824505 2018-07-23 78.91(a) Environmental Health & Safety
2760846 824506 2018-07-23 78.88(d) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
754356 340815 NOV - Notice of Violation
754356 344737 ADORD - Administrative Order 2018-12-26

For data sources see[7]

References