If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-25310 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.009266,"lon":-79.291388,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Redbank Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: | |
Farm/Lease Name: GLENN C. SHICK SR 4-101 | |
License Status: ACTIVE | |
Spud Date: | |
Permit Date: 1994-02-22 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.009266 | |
Longitude: -79.291388 |
Date | Event |
---|---|
1994-02-22 | New Permit Application |
1994-03-16 | Performed Spud Operation |
1994-03-22 | Drilling Completion |
1994-04-04 | Perforation |
1994-04-18 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
1996 | SNYDER BROS INC | 8469 | 214 | 40.77 | 214 | 0.00 | 0 |
1997 | SNYDER BROS INC | 11747 | 328 | 146.71 | 328 | 0.00 | 0 |
1998 | SNYDER BROS INC | 8947 | 327 | 25.73 | 327 | 0.00 | 0 |
1999 | SNYDER BROS INC | 7654 | 342 | 28.78 | 342 | 0.00 | 0 |
2000 | SNYDER BROS INC | 7057 | 322 | 0.00 | 0 | 0.00 | 0 |
2001 | SNYDER BROS INC | 5971 | 341 | 127 | 341 | 0.00 | 0 |
2002 | SNYDER BROS INC | 4859 | 346 | 0.00 | 0 | 0.00 | 0 |
2003 | SNYDER BROS INC | 3765 | 263 | 58.16 | 263 | 0.00 | 0 |
2004 | SNYDER BROS INC | 5219 | 310 | 5.2 | 310 | 0.00 | 0 |
2005 | SNYDER BROS INC | 5574 | 357 | 153 | 357 | 0.00 | 0 |
2006 | SNYDER BROS INC | 4276.00 | 284 | 108.00 | 284 | 0.00 | 0 |
2007 | SNYDER BROS INC | 4487.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2008 | SNYDER BROS INC | 3396.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2009 | SNYDER BROS INC | 3106.00 | 325 | 0.00 | 0 | 0.00 | 0 |
2010 | SNYDER BROS INC | 2,881.00 | 319 | 0.00 | 0 | 0.00 | 0 |
2011 | SNYDER BROS INC | 3,679.00 | 302 | 0.00 | 0 | 0.00 | 0 |
2012 | SNYDER BROS INC | 2,880.00 | 321 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 2,637.00 | 353 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 2,595.00 | 343 | 60.00 | 343 | 0.00 | 0 |
2015 | SNYDER BROS INC | 2,995.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 2,408.00 | 345 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 2,438.00 | 313 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 2,124.00 | 322 | 7.60 | 27 | 0.00 | 0 |
2019 | SNYDER BROS INC | 2,484.00 | 326 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2002 | SNYDER BROS INC | Brine | 25.00 Bbl | Road Spreading | |
2003 | SNYDER BROS INC | Brine | 45.00 Bbl | Brine or Industrial Waste Treatment Plt | |
2004 | SNYDER BROS INC | Brine | 35.00 Bbl | Road Spreading | |
2005 | SNYDER BROS INC | Brine | 55.00 Bbl | Reuse other than road spreading | 3701921388 |
2006 | SNYDER BROS INC | Brine | 45.00 Bbl | Reuse other than road spreading | |
2006 | SNYDER BROS INC | Brine | 15.00 Bbl | Road Spreading | |
2008 | SNYDER BROS INC | Brine | 45.00 Bbl | Reuse other than road spreading | |
2011 | SNYDER BROS INC | Produced Fluid | 40.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2014 | SNYDER BROS INC | Produced Fluid | 20.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0101508 |
2014 | SNYDER BROS INC | Produced Fluid | 20 Bbl | CENT WASTE TRT FAC NPDES | PA0101508 |
2017 | SNYDER BROS INC | Produced Fluid | 16.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1772757 | Primary Facility | 2009-02-27 | Routine/Complete Inspection | Violation(s) Noted | nspection performed as a follow-up to an oil spill which occurred and was reported to the Department on 02/20/09. Vince Yantko, ER Team responded to the spill report and a copy of the incident report is attacehed. Noted that the underflow dams which had been constructed onsite were functioning properly, and that any oil was accumatling on top of the water behind the underflow dams. Saw no visible evidence on the surface of the ground of any oil discharge, nor was there any evidence of oil contamination entering Redbank Creek. There were two roll off dumpsters located onsite, both of which were lined and covered. The operator should continue to monitor the site and spill control measures should remain onsite until all of the evidence of oil contamination is abated. |
1779672 | Primary Facility | 2009-03-31 | Compliance Evaluation | No Violations Noted | nspection performed as a follow-up to an oil spill which occurred and was reported to the Department on 02/20/09. Saw no visible evidence on the surface of the ground of any oil discharge, nor was there any evidence of oil contamination entering Redbank Creek. In addition there was no observed evidence of oil contamination accumulated beind the underflow dams implemented during the spill cleanup. |
215991 | Primary Facility | 1994-06-10 | Routine/Complete Inspection | No Violations Noted | E&S OK; TWO TANKS |
216108 | Primary Facility | 1994-08-12 | Routine/Complete Inspection | No Violations Noted | E&S OK; TANK |
216237 | Primary Facility | 1994-09-29 | Site Restoration | No Violations Noted | SITE RESTORED; TANK |
923765 | Primary Facility | 2000-03-14 | Routine/Complete Inspection | No Violations Noted | Tag, 2 tanks, e&s ok. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1772757 | 557397 | 02/20/2009 | 2009-02-20 | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
557397 | 243354 | NOV - Notice of Violation | Comply/Closed | 2009-03-31 | |||
557397 | 251251 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2009-10-16 | 2009-10-16 | $3,000.00 | $3,000.00 |
For data sources see[7]