37-005-27309

Well Details

Well ID: 37-005-27309
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Boggs Township
Operator Name: BAKER GAS INC
Well Pad ID:
Farm/Lease Name: E DEWITT MARTIN 4
License Status: ACTIVE
Spud Date:
Permit Date: 2003-08-01
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.869126
Longitude: -79.436606

For data sources see[1][2][3]

Well History

Date Event
2003-08-01 New Permit Application
2003-10-08 Performed Spud Operation
2003-10-09 Drilling Completion
2003-10-29 Perforation
2004-03-03 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2003 963 365 0.00 0 0.00 0
2004 17481 365 0.00 0 0.00 0
2005 12055 365 0.00 0 0.00 0
2006 10533.00 365 0.00 0 0.00 0
2007 8438.00 365 0.00 0 0.00 0
2008 185.09 366 0.00 0 0.00 0
2009 7229.00 365 0.00 0 0.00 0
2010 4,902.00 279 0.00 0 0.00 0
2011 4,803.00 281 0.00 0 0.00 0
2012 5,028.00 366 0.00 0 0.00 0
2013 4,566.00 365 0.00 0 0.00 0
2014 2,750.00 258 0.00 0 0.00 0
2015 3,634.00 302 0.00 0 0.00 0
2016 3,116.00 356 0.00 0 0.00 0
2017 2,494.00 360 0.00 0 0.00 0
2018 2,382.00 359 0.00 0 0.00 0
2019 1,816.00 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2019 Produced Fluid 50.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1415445 Primary Facility 2005-02-04 Site Restoration No Violations Noted equipped/restored/tank&tag ok
2587305 Primary Facility 2017-04-26 Routine/Complete Inspection No Violations Noted Well tagged-on-annulus shut. Well head casing-100 bbl fiberglass tank look ok.