X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-28396

Well Details

Well ID: 37-005-28396
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Kittanning Township
Operator Name: KRIEBEL WELLS DISSOLUTION CO LLC
Well Pad ID:
Farm/Lease Name: JACKSON 001
License Status:
Spud Date:
Permit Date: 2005-11-15
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.767475
Longitude: -79.446108

For data sources see[1][2][3]

Well History

Date Event
2005-11-15 New Permit Application
2006-11-01 Permit Renewal Application
2007-11-13 Permit Renewal Application
2008-11-18 Permit Renewal Application
2009-11-03 Performed Spud Operation
2009-11-06 Drilling Completion
2009-11-18 Perforation
2010-04-21 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 KRIEBEL MINERALS INC 4,327.00 266 0.00 0 0.00 0
2011 KRIEBEL MINERALS INC 5,419.00 324 0.00 0 0.00 0
2012 KRIEBEL MINERALS INC 4,944.00 324 15.21 324 0.00 0
2013 KRIEBEL MINERALS INC 4,201.00 322 0.00 0 0.00 0
2014 KRIEBEL MINERALS INC 3,579.00 320 0.00 0 0.00 0
2015 KRIEBEL MINERALS INC 2,879.00 298 0.00 0 0.00 0
2016 KRIEBEL MINERALS INC 2,761.00 300 0.00 0 0.00 0
2017 KRIEBEL WELLS DISSOLUTION CO LLC 2,574.00 317 0.00 0 0.00 0
2018 KRIEBEL WELLS DISSOLUTION CO LLC 2,344.00 309 0.00 0 0.00 0
2019 KRIEBEL WELLS DISSOLUTION CO LLC 2,230.00 320 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 KRIEBEL MINERALS INC Produced Fluid 20.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2013 KRIEBEL MINERALS INC Produced Fluid 50 Bbl CENT WASTE TRT FAC NPDES PA0095443
2013 KRIEBEL MINERALS INC Produced Fluid 50.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2015 KRIEBEL MINERALS INC Produced Fluid 10 Bbl CENT WASTE TRT FAC NPDES PA0095273
2015 KRIEBEL MINERALS INC Produced Fluid 10.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2017 KRIEBEL WELLS DISSOLUTION CO LLC Produced Fluid 10.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2019 KRIEBEL WELLS DISSOLUTION CO LLC Produced Fluid 40.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1843296 Primary Facility 2009-11-05 Routine/Complete Inspection No Violations Noted Drill rig located onsite and drilling was ongoing at the time of the inspection. Below grade pit located onsite and it had more than two feet of lined freeboard. No accelerated erosion & sedimentation was observed in relation to the access road or well-site. Noted that the culvert outlets were rocked properly, however they outlet into a disturbed area, thus negating the purpose of the sediment removal erosion controls. The Department recommends that the operator mulch the exposed disturbed area, especially the area below the access road where the culverts outlet.
1850004 Primary Facility 2009-12-15 Routine/Complete Inspection No Violations Noted Drilling had been completed, site had been partially regraded and the below grade pit had been backfilled. No accelerated erosion & sedimentation was observed in relation to the access road or well-site. Noted that the culvert outlets were rocked properly, however they outlet into a disturbed area, thus negating the purpose of the sediment removal erosion controls. The Department recommends that the operator mulch the exposed disturbed area, especially the area below the access road where the culverts outlet, as stated in the previous inspection dated 11/05/09.
1884106 Primary Facility 2010-05-13 Routine/Complete Inspection No Violations Noted Well appeared to beequipped for and in production at the time of the inspection. Brine tank located onsite, and it appeared to be holding fluids but a large dent was observed in the tank. The site had been regraded, seeded & mulched and it was noted that the vegetation had begun to grow however it did not meet the 70% uniform coverage criteria as of yet. The operator should continue to monitor the site to insure that the 70% uniform vegetative cover criteria is met.

For data sources see[7]

References