X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-30386

Well Details

Well ID: 37-005-30386
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Wayne Township
Operator Name: ECM EXPLORATION INC
Well Pad ID:
Farm/Lease Name: A PAUL REESMAN 2
License Status:
Spud Date:
Permit Date: 2009-07-08
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.925640
Longitude: -79.313030

For data sources see[1][2][3]

Well History

Date Event
2009-07-08 New Permit Application
2009-08-11 Performed Spud Operation
2009-08-14 Drilling Completion
2009-12-22 Perforation
2010-01-13 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 ECM EXPLORATION INC 859.00 84 0.00 0 0.00 0
2010 ECM EXPLORATION INC 7,258.00 365 0.00 0 0.00 0
2011 ECM EXPLORATION INC 7,050.40 365 0.00 0 0.00 0
2012 ECM EXPLORATION INC 7,468.00 365 0.00 0 0.00 0
2013 ECM EXPLORATION INC 6,764.00 365 0.00 0 0.00 0
2014 ECM EXPLORATION INC 5,575.00 365 0.00 0 0.00 0
2015 ECM EXPLORATION INC 5,278.00 365 0.00 0 0.00 0
2016 ECM EXPLORATION INC 2,670.00 365 0.00 0 0.00 0
2017 ECM EXPLORATION INC 2,495.05 365 0.00 0 0.00 0
2018 ECM EXPLORATION INC 1,569.00 365 0.00 0 0.00 0
2019 ECM EXPLORATION INC 1,540.25 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2009 ECM EXPLORATION INC Fracking Fluid 100.00 Bbl Brine or Industrial Waste Treatment Plt PA0101508
2010 ECM EXPLORATION INC Produced Fluid 80.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 ECM EXPLORATION INC Produced Fluid 160.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012 ECM EXPLORATION INC Produced Fluid 231.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2013 ECM EXPLORATION INC Produced Fluid 173.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2013 ECM EXPLORATION INC Produced Fluid 173 Bbl CENT WASTE TRT FAC NPDES PA0101508
2014 ECM EXPLORATION INC Produced Fluid 90.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2014 ECM EXPLORATION INC Produced Fluid 90 Bbl CENT WASTE TRT FAC NPDES PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1822220 Primary Facility 2009-08-20 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed at the time of the inspection. Below grade pit located onsite and it had momre than the two feet of required lined freeboard. Noted that in the E&S Plan located onsite the disposal method for the drill cuttings was not included. This information should be included in future well-site E&S Plans. Observed no accelerated erosion & sedimentation in relation to the access road or well-site. The erosion control measures had been installed properly and should effectively minimize accelerated erosion & sedimentation.
1823384 Primary Facility 2009-08-19 Drilling/Alteration No Violations Noted drilling complete - not equipped/ID&pit ok/E&S ok
1833045 Primary Facility 2009-10-05 Routine/Complete Inspection No Violations Noted Drilling was completed at the time of the inspection. Well did not appear to be equipped for production. Below grade pit still located onsite, and it had more than the required two feet of lined freeboard. The Department recommends that the operator close the pit, dispose of the fluids contained therein and the drill cuttings according to the regulations. In addition the operator should also implement erosion control BMP's to temporarily stabilize the site through the winter months, or regrade the site and seed & mulch the site with perrenial vegetation and a winter cover crop.
1897372 Primary Facility 2010-07-12 Site Restoration No Violations Noted Drilling was completed on 08/14/09. Well appeared to be equipped for & in production. Brine tank located onsite. Noted that the brine tank appeared to be older and it had a large amount of rust on it. No accelerated erosion & sedimentation in relation to the access road or well-site. No well tag was observed located on any of the well apparatus associated with the well. At this time the Department is requesting that the operator forward documentation or contact WQS Higgins no later than 08/03/10 that the well has been properly tagged with the appropriate permit number and well name.
1923602 Primary Facility 2010-08-17 Routine/Complete Inspection No Violations Noted Drilling complete and well producing gas. Site graded and vegetated. TAG on pipe to tank. Tank and equipment is rusty and scaling, apparently from another well

For data sources see[7]