X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-30536

Well Details

Well ID: 37-005-30536
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Manor Township
Operator Name: BLX INC
Well Pad ID: 147344
Farm/Lease Name: ARBUCKLE 1-67.3
License Status:
Spud Date:
Permit Date: 2009-12-28
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.791410
Longitude: -79.491611

For data sources see[1][2][3]

Well History

Date Event
2009-12-28 New Permit Application
2010-09-28 Performed Spud Operation
2011-01-05 Drilling Completion
2011-05-11 Perforation
2014-04-14 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 BLX INC 0.00 0 0.00 0 0.00 0
2011 BLX INC 13,842.00 58 0.00 0 0.00 0
2012 BLX INC 39,431.00 334 0.00 0 0.00 0
2013 BLX INC 28,090.00 351 0.00 0 0.00 0
2014 BLX INC 18,332.00 306 0.00 0 0.00 0
2015 BLX INC 18,682.00 354 0.00 0 0.00 0
2016 BLX INC 16,898.00 350 0.00 0 0.00 0
2017 BLX INC 14,999.00 359 0.00 0 0.00 0
2018 BLX INC 13,681.00 358 0.00 0 0.00 0
2019 BLX INC 11,877.00 360 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 BLX INC Fracing Fluid Waste 410.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2011 BLX INC Fracing Fluid Waste 4,735.71 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674
2011 BLX INC Fracing Fluid Waste 105.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2011 BLX INC Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-155-22403
2011 BLX INC Drilling Fluid Waste 300.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011 BLX INC Produced Fluid 87.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-007-24355
2012 BLX INC Produced Fluid 400.00 Bbl INJECTION DISPOSAL WELL 34-155-22403
2012 BLX INC Produced Fluid 33.33 Bbl INJECTION DISPOSAL WELL 34-155-21894
2012 BLX INC Produced Fluid 133.33 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012 BLX INC Produced Fluid 33.34 Bbl INJECTION DISPOSAL WELL 34-155-23203
2013 BLX INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-133-23614
2013 BLX INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-155-22403
2016 BLX INC Produced Fluid 115.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2016 BLX INC Produced Fluid 60.00 Bbl REUSE OTHER THAN ROAD SPREADING
2019 BLX INC Produced Fluid 95.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2019 BLX INC Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-155-23196

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1917976 Primary Facility 2010-10-05 Routine/Complete Inspection No Violations Noted Site construction was underway, drilling was not ongoing at the time of the inspection. Noted that the silt fencing had not been installed properly and that due to access road construction the road should be rocked with clean durable rock and maintained as such during well development. Contacted operator representative Walt Emquist regarding these matters. Mr. Emquist stated that the previous day the access road had been discussed and it was decided to rock the entire road up to the site with R3 rock. In addition he stated that he will have the silt fencing issue addressed as soon as possible.
1923331 Primary Facility 2010-10-28 Routine/Complete Inspection No Violations Noted Site construction had been completed, drilling was not ongoing at the time of the inspection. Both drill and frac pits located onsite, however they had not been lined. All access road and site erosion controls had been implemented properly and no accelerated erosion & sedimentation was observed in relation to the site or access road.
1929890 Primary Facility 2010-10-27 Drilling/Alteration No Violations Noted conductor set/E&S ok/ID&pit ok
1933568 Primary Facility 2010-12-01 Drilling/Alteration No Violations Noted currently not drilling/E&S ok/ID&pit ok
1944040 Primary Facility 2011-01-20 Routine/Complete Inspection No Violations Noted Drilling had been undertaken but was not ongoing at the time of the inspection. Drill pit contained drill cuttings and what appeared to be a frozen liquid fraction. The pit had more than the required two feet of lined freeboard. Observed no accelerated erosion & sedimentation in relation to the access road or site.
1955889 Primary Facility 2011-03-09 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed. Drill pit located onsite and it contained cuttings and fluids. The pit had more than the required two feet of lined freeboard. There was no observed accelerated erosion & sedimentation in relation to the access road or site. Noted that the disturbed areas which would not be utilized during well development had been mulched as an additional temporary erosion control BMP and that the entire access road had been rocked with clean durable rock.
1968522 Primary Facility 2011-04-26 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed. Drill pit located onsite and it contained cuttings and fluids. The pit had more than the required two feet of lined freeboard. There was no observed accelerated erosion & sedimentation in relation to the access road or site. Noted that the disturbed areas which would not be utilized during well development had been mulched as an additional temporary erosion control BMP. Operator was transferring fluids from the drill pit and rainwater collected in one of the unlined frac pits to the lined frac pit. The lined frac pit had more than the required two feet of lined freeboard.
1972171 Primary Facility 2011-05-12 Administrative/File Review Viol(s) Noted & Immediately Corrected
1975742 Primary Facility 2011-05-24 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed. Drill pit had been regraded. Well appears to have been stimulated. Frac impoundments located onsite contained fluids and they had more than the required two feet of lined freeboard. Observed no accelerated erosion or sedimentation in relation to the access road or well-site.
2039456 Primary Facility 2012-02-02 Routine/Complete Inspection No Violations Noted Drilling had been completed, well appeared to be equipped to production. Brine tanks located onsite and they appeared to be in sound condition. Site had been regraded, seeded. mulched and a good portion of the site had vegetation. It was noted that approximately 1/3 of what had been the well site had been disturbed for a home and sand mound construction. This home now shares the access road with the gas well.
2235753 Primary Facility 2014-01-13 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. Site had been restored and the vegetative cover met the 70% uniform coverage criteria. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2540124 Primary Facility 2016-11-30 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2558960 Primary Facility 2017-02-02 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production set equipment-2 grounded 100 bbl fiberglass tanks looked ok.
2707693 Primary Facility 2018-03-15 Routine/Complete Inspection In Compliance with Policy At time of inspection, well drilled and appears equipped for production.

The Department attempted to reach two operator representatives by phone to notify the operator of the below-noted observations. At 1201, operator representative Gretchen called the Department. Gretchen stated that personnel would be directed to the location to investigate and will follow-up with the Department. The Department is requesting the following information at this time: The last time the brine tank was inspected and the tank readings from the last time the tank was emptied through today. The operator appears to be in compliance with policy at this time. Violations may be forthcoming pending operator response and investigation.

2715858 Primary Facility 2018-03-27 Administrative/File Review In Compliance with Policy Admin inspection in response to inspection record 2707693.

Operator representative Brandon Mayhugh contacted the Department by phone to follow-up on the Department's observations observed under inspection record 2707693.

Per Mr. Mayhugh: The tanks were repaired. It is not believed that the seeps were a leak, but perhaps moisture trapped under the paint of the tanks. There was no loss of fluid per tank readings and the fluid levels were previously below these observed seeps. The operator will continue to monitor the tanks as necessary in order to ensure these seeps do not reappear.

2741041 Primary Facility 2018-06-13 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is shut. The well head casing, piping, production set equipment, containment dike and two grounded 100 bbl fiberglass fluid collection tanks look ok.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1972171 610768 05/12/2011 2011-05-12 212WELLRCD - Failure to submit well record within 30 days of completion of drilling Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
610768 271425 CACP - Consent Assessment of Civil Penalty Comply/Closed 2011-06-09 2011-06-09 $1,000.00 $1,000.00

For data sources see[7]

References