If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30597 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.805617,"lon":-79.264556,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Cowanshannock Township | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: SAMUEL GOLDSTROHM 1 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-05-03 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.805617 | |
Longitude: -79.264556 |
Date | Event |
---|---|
2010-05-03 | New Permit Application |
2010-08-02 | Performed Spud Operation |
2010-08-09 | Drilling Completion |
2010-08-23 | Perforation |
2010-12-02 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ALCOVE INVESTMENTS | 923.00 | 90 | 0.00 | 0 | 0.00 | 0 |
2011 | ALCOVE INVESTMENTS | 9,553.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | ALCOVE INVESTMENTS | 7,142.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2013 | ALCOVE INVESTMENTS | 5,397.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | ALCOVE INVESTMENTS | 4,979.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | ALCOVE INVESTMENTS | 3,694.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | ALCOVE INVESTMENTS | 3,784.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | ALCOVE INVESTMENTS | 3,083.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | ALCOVE INVESTMENTS | 3,199.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | ALCOVE INVESTMENTS | 2,859.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | ALCOVE INVESTMENTS | Produced Fluid | 75.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1902365 | Primary Facility | 2010-08-02 | Routine/Complete Inspection | No Violations Noted | Drill rig onsite. Drilling had not as of yet commenced. Pit was not lined, and recommended to the drill crew onsite to have the pit lined with hay and/or straw prior to placing the liner in the pit. E&S plan could not be reviewed due to the plan tube being too long and vertical. No accelerated erosion & sedimentation in relation to the access road or well-site. Silt fencing had been installed properly. Noted that the rock construction entrance should be expanded on the access road. |
1908238 | Primary Facility | 2010-08-05 | Drilling/Alteration | No Violations Noted | drilling @ 2880ft |
1981756 | Primary Facility | 2011-06-20 | Site Restoration | No Violations Noted | Drilling was completed on 08/09/10. Well appeared to be equipped for production. Brine tank located onsite and appeared to be equipped for production. Observed no accelerated erosion or sedimentation in relation to the access road or well-site. Noted that there was no well tag observed on any of the well apparatus located onsite. |
2462728 | Primary Facility | 2016-03-07 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Annulus plumbed-open. Well head casing-equipment-100 bbl tank look ok. |
2644355 | Primary Facility | 2017-10-06 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The annulus is shut. The well head casing and grounded 100 bbl fiberglass tank look ok. |
For data sources see[7]