If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30613 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.822885,"lon":-79.327485,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Cowanshannock Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 148233 | |
Farm/Lease Name: DICKEY 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-04-15 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.822885 | |
Longitude: -79.327485 |
Date | Event |
---|---|
2010-04-15 | New Permit Application |
2010-08-22 | Performed Spud Operation |
2010-11-14 | Drilling Completion |
2010-12-03 | Perforation |
2011-12-14 | DEVIATED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA INC | 782,951.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 503,385.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 373,917.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 283,014.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 270,853.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 231,130.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 200,954.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | EXCO RESOURCES PA LLC | 178,973.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | EXCO RESOURCES PA LLC | 154,779.00 | 325 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | EXCO RESOURCES PA INC | Fracing Fluid Waste | 17,475.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2010 | EXCO RESOURCES PA INC | Drilling Fluid Waste | 2,031.40 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2010 | EXCO RESOURCES PA INC | Drilling Fluid Waste | 888.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2011 | EXCO RESOURCES PA INC | Produced Fluid | 110.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | EXCO RESOURCES PA INC | Produced Fluid | 323.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095443 |
2011 | EXCO RESOURCES PA INC | Produced Fluid | 393.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EXCO RESOURCES PA INC | Produced Fluid | 120.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2011 | EXCO RESOURCES PA INC | Produced Fluid | 2,034.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAS2D205BCLE |
2011 | EXCO RESOURCES PA INC | Fracing Fluid Waste | 5,917.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EXCO RESOURCES PA INC | Produced Fluid | 2,379.63 Bbl | INJECTION DISPOSAL WELL | 34-119-27350 |
2011 | EXCO RESOURCES PA INC | Produced Fluid | 2,876.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 1,895.45 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 445.89 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 501.13 Bbl | INJECTION DISPOSAL WELL | 34-119-27350 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 2,132.38 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 200.40 Bbl | INJECTION DISPOSAL WELL | 34-013-20611 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 227.12 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 3,747.48 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 2,556.33 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 35.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | 2014-07 |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 3,075.50 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2016 | EXCO RESOURCES PA LLC | Produced Fluid | 2,266.30 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2016 | EXCO RESOURCES PA LLC | Produced Fluid | 314.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | EXCO RESOURCES PA LLC | Produced Fluid | 2,091.30 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2017 | EXCO RESOURCES PA LLC | 1,413.30 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE | |
2017 | EXCO RESOURCES PA LLC | Produced Fluid | 105.20 Bbl | REUSE (AT WELL PAD) | |
2017 | EXCO RESOURCES PA LLC | 105.20 Bbl | REUSE (AT WELL PAD) | ||
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 302.20 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 1,467.50 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 1,645.90 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1909905 | Primary Facility | 2010-09-01 | Routine/Complete Inspection | No Violations Noted | Drill rig located onsite and drilling was ongoing at the time of the inspection. Erosion controls implemented as outlined in the E&S plan. No accelerated erosion & sedimentation was observed in relation to the access road or well-site. Below grade pit located onsite and it had more than the required two feet of lined freeboard. Frac pit located at the Dickey 2H site will likely be utilized for well stimulation at the Dickey 3H. |
1913588 | Primary Facility | 2010-09-02 | Routine/Complete Inspection | No Violations Noted | top-hole completed - rigging down/E&S ok/ID&pit ok |
1918576 | Primary Facility | 2010-10-07 | Routine/Complete Inspection | No Violations Noted | Drill rig located onsite, but drilling was not ongoing at the time of the inspection. No pit located onsite. All drill cuttings are to be taken off-site. No accelerated erosion & sedimentation was observed in relation to the access road or well-site. |
1919953 | Primary Facility | 2010-10-05 | Drilling/Alteration | No Violations Noted | rigging-up/E&S ok/ID&pit(tank) ok |
1919954 | Primary Facility | 2010-09-29 | Drilling/Alteration | No Violations Noted | rigging-up/E&S ok/ID ok |
1920687 | Primary Facility | 2010-10-13 | Drilling/Alteration | No Violations Noted | BOP tested - past to 5000psi/E&S ok/ID&pit ok |
1922501 | Primary Facility | 2010-10-20 | Drilling/Alteration | No Violations Noted | Directional drilling at 2556' |
1928765 | Primary Facility | 2010-11-17 | Routine/Complete Inspection | No Violations Noted | Drill rig onsite, drilling did not appear to be ongoing during inspection. During a cement job on the morning of 11/17/10 a fitting broke releasing approximately one barrel of a synthetic drill mud to the well pad and adjacent pad liner. In response to this spill the operator began clean-up operations after contacting OGI Supervisor Ed Renwick. At the time of the inspection it was noted that the drill mud had stayed on the surface of the well pad and that the affected media was being gathered and placed with the drill cuttings to be hauled off-site as there is no drill pit onsite. WQS Higgins spoke with Exco representative Doug Byers and requested that he forward via e-mail an outline of when the spill occurred, when cleanup began, what the clean-up consisted of, and when the clean-up was completed. Mr. Byers indicated that this should be compiled and forwarded the morning of 11/18/10. This information was received on 11/18/10 at 11:40 AM. |
1929875 | Primary Facility | 2010-11-02 | Drilling/Alteration | No Violations Noted | drilliing @ 7597ft/E&S ok/ID&pit ok |
1929886 | Primary Facility | 2010-10-20 | Drilling/Alteration | No Violations Noted | drilling/E&S ok/ID&tank ok - no pit |
1930822 | Primary Facility | 2010-11-24 | Follow-up Inspection | Violation(s) Noted | re-inspection for ESX10-005-0007 for erosion and sed. violations, wetland and stream encroached and damaged, construction of gasline outside of permit area of disturbance on Frederick property, silt fence not maintained, water bar on access road to compressor station not properly constructed, slit fence installed across streams. Advised operator, Perry Lupinetti of EXCO, to restore streams and construct proper stream crossing on Frederick property, need better maintenace on silt fences and repair water bar on access road |
1952058 | Primary Facility | 2011-02-22 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed, wells appeared to be equipped for production at the time of the inspection. Brine tanks located onsite and appeared to be in sound condition. Site had not as of yet been regraded. Erosion controls appeared to be holding up and would continue to function properly. |
1957427 | Primary Facility | 2011-03-15 | Routine/Complete Inspection | Viol(s) Noted & Immediately Corrected | Drilling had been completed, wells appeared to be equipped for production at the time of the inspection. Brine tanks located onsite and appeared to be in sound condition. Site inspection performed as a follow-up to a release of production fluids reported by the operator on 03/11/11. Due to a pipe failure on the production unit for the 3H well a mist of production fluids was released to the immediate area around the 3H and 1H production units. Due to this the affected media was excavated, contained onsite in plastic pending sample results. The affected area was subsequently sampled to insure that all of the affected media had been removed. Visual inspection found that it did not appear that the fluid release had made it past the area excavated immediately surrounding the production units. Documentation from the operator detailing how the release occurred, cleanup activities and actions taken to prevent a reoccurrence is forthcoming after a phone conversation with operator representative Doug Byers. |
1974143 | Primary Facility | 2011-03-31 | Routine/Complete Inspection | Violation(s) Noted | Inspection in response to a methanol spill. Contaminated media had been excavated and contained onsite prior to site inspection. |
1975583 | Primary Facility | 2011-04-28 | Compliance Evaluation | No Violations Noted | Drilling had been completed, wells appeared to be equipped for production at the time of the inspection. Brine tanks located onsite and appeared to be in sound condition. Noted that the excavated material from two recent fluid discharges was still onsite on and covered by plastic. Observed no accelerated erosion or sedimentation in relation to the access road or well-site. |
2075386 | Primary Facility | 2012-06-08 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed, site had been regraded. Well appeared to be equipped for production. Brine tanks located onsite and they are within containment. Containment contained minimal precipiation water which showed no sheen. Noted that the vegetative cover did not meet the 70% uniform coverage criteria. Spoke with EXCO representative Ted Parrish regarding this matter and he stated that he is contacting a contractor today to have the site reseeded as the grass seed drilled with the oat seed had not germinated. |
2208023 | Primary Facility | 2013-09-12 | Routine/Complete Inspection | No Violations Noted | There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. All site and road erosion controls appeared to have been maintained and were functioning properly. Well appeared to be equipped for production. Brine tank located onsite within secondary containment and the tank and containment appeared to be in sound condition. |
2264071 | Primary Facility | 2014-04-18 | Routine/Complete Inspection | No Violations Noted | There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. All site and road erosion controls appeared to have been maintained and were functioning properly. Well appeared to be equipped for production. Brine tank located onsite within secondary containment and the tank and containment appeared to be in sound condition. |
2385009 | Primary Facility | 2015-06-30 | Routine/Complete Inspection | No Violations Noted | Wells were appropriately labeled and brine tanks located onsite. Brine tanks appeared to be in sound condition. There was no observed accelerated erosion & sedimentation in relation to the site or access road. |
2471997 | Primary Facility | 2016-04-06 | Routine/Complete Inspection | No Violations Noted | 2 tanks onsite. Tag and e&s ok. |
2509648 | Primary Facility | 2016-08-10 | Routine/Complete Inspection | No Violations Noted | Well was appropriately labeled and brine tank located onsite. Brine tank appeared to be in sound condition. There was no observed accelerated erosion & sedimentation in relation to the site or access road. |
2615340 | Primary Facility | 2017-07-14 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2666191 | Primary Facility | 2017-12-01 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, production set equipment, tank battery and dike containment look ok. |
2691306 | Primary Facility | 2018-01-25 | Routine/Complete Inspection | No Violations Noted | At time of inspection, well 1H drilled and appears equipped for production. Well 3H also drilled and appears equipped for production. |
2752456 | Primary Facility | 2018-07-17 | Routine/Complete Inspection | No Violations Noted | Multi-well pad. At time of inspection, wells 3H and 1H drilled and appear equipped for production. |
2829081 | Primary Facility | 2019-01-17 | Routine/Complete Inspection | No Violations Noted | On 1/17/19 at 1335 hrs., I conducted a routine inspection of Exco Resources (PA), LLC's Dickey 3H well (API 005-30613) in Cowanshannock Twp., Armstrong Co. The well is equipped for production and well tag is present at the well head. There are no violations noted for this inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1930822 | 600469 | 11/24/2010 | 2010-11-24 | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | Administrative | |
1930822 | 600470 | 11/24/2010 | 2010-11-24 | 105GEN - Encroachment-General | Administrative | |
1957427 | 607784 | 03/15/2011 | 2011-03-15 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
1974143 | 611437 | 03/31/2011 | 2011-03-31 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
1974143 | 611438 | 03/31/2011 | 2011-03-31 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
611437 | 270720 | NOV - Notice of Violation | Comply/Closed | 2011-05-25 | |||
611438 | 270720 | NOV - Notice of Violation | Comply/Closed | 2011-05-25 |