37-005-30826

Well Details

Well ID: 37-005-30826
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Rayburn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 149253
Farm/Lease Name: SCHRECENGOST PAD 8 UNIT 3H
License Status:
Spud Date:
Permit Date: 2011-05-04
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.825039
Longitude: -79.475625

For data sources see[1][2][3]

Well History

Date Event
2011-05-04 New Permit Application
2011-06-23 Performed Spud Operation
2011-09-01 Drilling Completion
2011-10-24 Perforation
2014-07-16 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-10-24 2011-10-24 6,771 6,162,800

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Calfrac Well Services Propping Agent Quartz 14808-60-7 99.90 12.29
DAP-103 Calfrac Well Services Iron Control Citric acid 77-92-9 60.00 0.00283000
DAP-923 Calfrac Well Services Corrosion Inhibitor Fatty acids, tall-oil 61790-12-3 30.00 0.00034000
Propargyl alcohol 107-19-7 10.00 0.00011000
Alkenes, C>10 .alpha.- 64743-02-8 5.00 0.00006000
Methanol 67-56-1 60.00 0.00068000
Thiourea polymer 68527-49-1 30.00 0.00034000
Ethoxylated C14-15 alcohols 68951-67-7 30.00 0.00034000
DWP-944 Calfrac Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Polyethylene glycol 25322-68-3 70.00 0.02
3 HCl Acid Calfrac Well Services Perforation Breakdown Hydrochloric acid 7647-01-0 100.00 0.64
DAP-901 Calfrac Well Services Scale Inhibitor Oxyalkylated polyamine 5.00 0.00096000
Amine salt 5.00 0.00096000
Organic phosphonate 30.00 0.00574000
Ammonium chloride 12125-02-9 10.00 0.00191000
Phosphoric acid ammonium salt 5.00 0.00096000
Methanol 67-56-1 30.00 0.00574000
DWP-612 Calfrac Well Services Friction Reducer No Hazardous Materials 100.00 0.07
Water Base Fluid Water 100.00 86.91

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 386,096.00 124 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 731,736.00 365 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 520,029.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 402,673.00 365 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 348,768.00 360 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 292,627.00 362 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 240,904.00 364 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 214,445.00 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 3,145.72 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 125.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 EXCO RESOURCES PA LLC Fracing Fluid Waste 9,183.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Produced Fluid 2,052.70 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2012 EXCO RESOURCES PA LLC Drilling Fluid Waste 1,007.62 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2012 EXCO RESOURCES PA LLC Produced Fluid 217.89 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Drill Cuttings 733.35 Tons LANDFILL 100434
2012 EXCO RESOURCES PA LLC Fracturing Fluid Waste 24.81 Tons LANDFILL 100585
2012 EXCO RESOURCES PA LLC Produced Fluid 106.88 Bbl INJECTION DISPOSAL WELL 34-119-27350
2012 EXCO RESOURCES PA LLC Drill Cuttings 83.12 Tons LANDFILL 100585
2012 EXCO RESOURCES PA LLC Produced Fluid 534.73 Bbl STORAGE PENDING DISPOSAL OR REUSE
2012 EXCO RESOURCES PA LLC Produced Fluid 2,619.87 Bbl INJECTION DISPOSAL WELL 34-013-20611
2012 EXCO RESOURCES PA LLC Fracing Fluid Waste 4,610.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Produced Fluid 440.24 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Produced Fluid 3,511.74 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 2,631.48 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2015 EXCO RESOURCES PA LLC Produced Fluid 1,692.40 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 1,103.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 208.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EXCO RESOURCES PA LLC Produced Fluid 796.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC 517.60 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 103.50 Bbl REUSE (AT WELL PAD)
2017 EXCO RESOURCES PA LLC 103.50 Bbl REUSE (AT WELL PAD)
2018 EXCO RESOURCES PA LLC Produced Fluid 102.50 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018 EXCO RESOURCES PA LLC Produced Fluid 532.70 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 533.80 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1988153 Primary Facility 2011-07-12 Drilling/Alteration No Violations Noted Tripping in w/ 17 1/2"
1988158 Primary Facility 2011-06-29 Drilling/Alteration No Violations Noted Drlg @ 180'
1988228 Primary Facility 2011-07-15 Drilling/Alteration No Violations Noted WOC
1988391 Primary Facility 2011-07-06 Drilling/Alteration No Violations Noted Reaming Hole; spoke with M. Jackson & D. Stivanson
1988986 Primary Facility 2011-07-19 Drilling/Alteration No Violations Noted Dusting at 1360'
1991850 Primary Facility 2011-07-27 Drilling/Alteration No Violations Noted HWD moving in
1994072 Primary Facility 2011-08-02 Drilling/Alteration No Violations Noted Rig to test BOPs
1994301 Primary Facility 2011-08-04 Drilling/Alteration No Violations Noted Tripping in hole
1995673 Primary Facility 2011-08-12 Drilling/Alteration No Violations Noted @6117" ; Tripping in hole
1997453 Primary Facility 2011-08-17 Drilling/Alteration No Violations Noted Kicking of @ 5787'.
2021867 Primary Facility 2011-11-23 Routine/Complete Inspection No Violations Noted Drilling was not ongoing at the time of the inspection. Erosion controls had been implemented as outlined in the E&S plan contained within ESCGP. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. Frac impoundments located onsite and they were properly lined and had more than the required two feet of lined freeboard.
2030142 Primary Facility 2011-12-28 Routine/Complete Inspection No Violations Noted Shut-in preparing for additional wells to be drilled
2032437 Primary Facility 2012-01-03 Drilling/Alteration No Violations Noted preparing site
2034747 Primary Facility 2012-01-10 Drilling/Alteration No Violations Noted Drilled; shut-in
2056811 Primary Facility 2012-04-03 Routine/Complete Inspection No Violations Noted Shut in
2056984 Primary Facility 2012-04-06 Administrative/File Review Viol(s) Noted & Immediately Corrected
2076807 Primary Facility 2012-06-15 Routine/Complete Inspection No Violations Noted operating thru flow back sysytem.
2077681 Primary Facility 2012-06-20 Routine/Complete Inspection No Violations Noted Drilling was not ongoing at the time of the inspection. Wells were in the process of being equipped for production. Frac flowback and the freshwater impoundment contained fluids and both had more than the required two feet of lined freeboard. Work was underway to equip the wells onsite for production. Brine tanks were installed and appeared to be in sound condition. Six frac tanks were located onsite and there was no visible evidence of any spills or leaks related to the frac tanks. Site and access road erosion controls had been implemented and maintained properly.
2086797 Primary Facility 2012-07-27 Routine/Complete Inspection No Violations Noted Drilling had been completed, well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Erosion controls had been properly implemented and maintained. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site.
2101382 Primary Facility 2012-09-20 Routine/Complete Inspection No Violations Noted Drilling had been completed, well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Erosion controls had been properly implemented and maintained. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site.
2105815 Primary Facility 2012-10-04 Routine/Complete Inspection No Violations Noted operating
2148882 Primary Facility 2013-03-18 Routine/Complete Inspection No Violations Noted Drilling had been completed, well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Erosion controls had been properly implemented and maintained. Site had been temporarily stabilized. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site.
2198176 Primary Facility 2013-08-22 Routine/Complete Inspection No Violations Noted operating w/ proper ID
2198181 Primary Facility 2013-08-22 Routine/Complete Inspection No Violations Noted operating proper ID OK
2230463 Primary Facility 2013-12-09 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Erosion controls had been properly implemented and maintained. Site had been temporarily stabilized. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site.
2244567 Primary Facility 2014-02-11 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Site was snow covered.
2293413 Primary Facility 2014-08-05 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no accelerated erosion or sedimentation observed in relation to the site or access road.
2330936 Primary Facility 2014-12-11 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no accelerated erosion or sedimentation observed in relation to the site or access road.
2359973 Primary Facility 2015-04-08 Routine/Complete Inspection No Violations Noted There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tank located onsite and it appeared to be in sound condition.
2444307 Primary Facility 2016-01-28 Routine/Complete Inspection No Violations Noted There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tank located onsite and it appeared to be in sound condition. Well appeared to be equipped for production.
2506406 Primary Facility 2016-08-01 Routine/Complete Inspection No Violations Noted There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tank located onsite and it appeared to be in sound condition. Well appeared to be equipped for production.
2556666 Primary Facility 2017-01-30 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment looked ok.
2589779 Primary Facility 2017-05-03 Routine/Complete Inspection No Violations Noted All site and access road erosion controls had been properly implemented and maintained as outlined in the ESCGP. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Site had been effectively stabilized with vegetative cover. Waste fluid storage tank located onsite and it appeared to be in sound condition.
2673223 Primary Facility 2017-12-20 Routine/Complete Inspection No Violations Noted At time of inspection, well 3H drilled and appears equipped for production. Wells 1H, 2H, and 5H also drilled and appear equipped for production.
2798957 Primary Facility 2018-11-05 Routine/Complete Inspection No Violations Noted Well appears equipped for production. Well head surrounded by cement barriers. Three brine tanks located in secondary containment on site. One brine tank not located in secondary containment, on site.
2836792 Primary Facility 2019-02-05 Routine/Partial Inspection No Violations Noted At the time of inspection, well was producing. Well integrity appeared to be in good condition, with no signs of any leaks. There was some minor rust. The cellar was filled with gravel. The pressure reading for the tubing was reading 282 psi. The well was properly labeled and the Emergency Response sign was posted at the site entrance. There were 4 tanks on the pad. 3 were contained within a lined, steel dike and 1 was not contained. 3 line heaters were in use, 1 being a dual heater.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2056984 636225 04/06/2012 2012-04-06 212WELLRCD - Failure to submit well record within 30 days of completion of drilling Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
636225 282874 CACP - Consent Assessment of Civil Penalty Comply/Closed 2012-04-20 2012-04-20 $500.00 $500.00

For data sources see[8]

References