If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30855 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.950067,"lon":-79.429158,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Madison Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 147333 | |
Farm/Lease Name: ROBERT MCKAY (MOHNEY) 3M-162 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-07-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.950067 | |
Longitude: -79.429158 |
Date | Event |
---|---|
2011-07-14 | New Permit Application |
2012-03-13 | Performed Spud Operation |
2012-08-10 | Drilling Completion |
2012-10-12 | Perforation |
2013-06-11 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-10-15 | 2012-10-15 | 6,890 | 160,722 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SUPER MAX | Superior Well Services | Surfactant/Foamer | PROPRIETARY | 7.00 | 0.00620960 | ||
2-Butoxyethanol | 111-76-2 | 7.00 | 0.00620960 | |||||
Isopropanol | 67-63-0 | 30.00 | 0.02 | |||||
2-Ethylhexanol | 104-76-7 | 40.00 | 0.03 | |||||
Hydrochloric Acid | Superior Well Services | Cement/Formation Breakdown | Water | 7732-18-5 | 92.50 | 0.22 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.01 | |||||
SUPER TSC | Superior Well Services | Paraffin & Scale Additive | 1,2,4-Butanetricarboxylic acid, 2-phosphono- | 37971-36-1 | 10.00 | 0.00036260 | ||
ICP-1000 | Superior Well Services | Iron Control Additive | ANIONIC COPOLYMER | 50.00 | 0.00362570 | |||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00362570 | |||||
ACID INHIBITOR 2 | Superior Well Services | Acid Corrosion Inhibitor | PROPRIETARY | 0.00005080 | ||||
Propargyl alcohol | 107-19-7 | 0.00021750 | ||||||
Isopropanol | 67-63-0 | 0.00021750 | ||||||
2-Butoxyethanol | 111-76-2 | 0.00021750 | ||||||
WFR-3B | Superior Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
1,2-Propylene glycol | 57-55-6 | 25.00 | 0.01 | |||||
Ethoxylated C12-16 alcohols | 68551-12-2 | 4.00 | 0.00299730 | |||||
Stoddard solvent | 8052-41-3 | 10.00 | 0.00749310 | |||||
SUPER TSC | Superior Well Services | Scale Control | 1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00181290 | ||
ANIONIC COPOLYMER | 10.00 | 0.00036260 | ||||||
ANIONIC POLYMER | 10.00 | 0.00036260 | ||||||
CLAY TREAT LT | Superior Well Services | Clay Control | Choline chloride | 67-48-1 | 80.00 | 0.00038670 | ||
KR-153SL | Superior Well Services | Biocide | Polyethylene glycol | 25322-68-3 | 50.00 | 0.00181290 | ||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00072510 | |||||
Diethylene glycol | 111-46-6 | 3.50 | 0.00012690 | |||||
Ethylene glycol | 107-21-1 | 1.00 | 0.00003630 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SNYDER BROS INC | 15,224.00 | 41 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 38,074.00 | 358 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 19,890.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 12,924.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 9,669.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 7,769.00 | 357 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 6,305.00 | 354 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 5,875.00 | 344 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SNYDER BROS INC | Produced Fluid | 160.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2012 | SNYDER BROS INC | Drill Cuttings | 109.00 Tons | ON SITE ENCAPSULATION | |
2012 | SNYDER BROS INC | Produced Fluid | 324.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23584 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 765.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012 | SNYDER BROS INC | Produced Fluid | 83.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 525-1 |
2012 | SNYDER BROS INC | Produced Fluid | 83.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2013 | SNYDER BROS INC | Produced Fluid | 428.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2013 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2014 | SNYDER BROS INC | Produced Fluid | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW009 |
2015 | SNYDER BROS INC | Produced Fluid | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW009 |
2016 | SNYDER BROS INC | Produced Fluid | 17.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2018 | SNYDER BROS INC | Produced Fluid | 82.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2050578 | Primary Facility | 2012-03-14 | Routine/Complete Inspection | No Violations Noted | Site construction had been completed, drilling had not commenced. Drill pit located onsite and it was properly lined. Erosion controls had been properly as outlined in the E&S plan located onsite. There was no observed acelerated erosion or sedimentation in relation to the access road or well-site. |
2051632 | Primary Facility | 2012-03-13 | Drilling/Alteration | No Violations Noted | rigging up on site |
2058552 | Primary Facility | 2012-04-04 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed, well was not equipped for production. Drill pit locate onsite. Pit contained cuttings and fluids and it had more than the required two feet of lined freeboard. There was no observed accelerated erosion or sedimentation observed in relation to the access road or well-site. |
2070009 | Primary Facility | 2012-05-22 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed, well was not equipped for production. Drill pit located onsite. Pit contained cuttings and fluids and it had more than the required two feet of lined freeboard. There was no observed accelerated erosion or sedimentation observed in relation to the access road or well-site. |
2089195 | Primary Facility | 2012-08-02 | Drilling/Alteration | No Violations Noted | resumption of drilling notification provided |
2090678 | Primary Facility | 2012-08-08 | Drilling/Alteration | No Violations Noted | Tripping in 2 7/8" DP at 5770' |
2101337 | Primary Facility | 2012-09-17 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed. Drill pit located onsite. Drill pit contained drill cuttings and fluids. Pit had more than the required two feet of lined freeboard. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. |
2168113 | Primary Facility | 2013-05-15 | Site Restoration | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and it appeared to be in sound condition. No accelerated erosion or sedimentation was observed in relation to the access road or well-site. Site had been regraded and temporarily stabilized. The operator should continue to monitor the site to insure 70% uniform vegetative cover is achieved. |
2205350 | Primary Facility | 2013-09-18 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and it appeared to be in sound condition. No accelerated erosion or sedimentation was observed in relation to the access road or well-site. Noted that the majority of what had been the well-site had been tilled for use as a cultivated field. |
2491564 | Primary Facility | 2016-06-07 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2828280 | Primary Facility | 2019-01-16 | Routine/Complete Inspection | No Violations Noted | On 1/16/19 at 1024 hrs., I conducted a routine inspection of Snyder Brothers, Inc.'s Robert McKay 3M-162well (API 005-30855) in Madison Twp., Armstrong Co. The well pad is restored and permanently stabilized. The well is equipped for production. A site ID sign is present at the entrance to the well pad. A well tag is affixed to the well head. There are no violations noted for this inspection. |
For data sources see[8]