If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30856 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.923478,"lon":-79.385014,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Mahoning Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 147430 | |
Farm/Lease Name: ROBERT E PATRICK JR | |
License Status: Plugged and Abandoned | |
Spud Date: 2012-03-22 | |
Permit Date: 2011-07-05 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.923478 | |
Longitude: -79.385014 |
Date | Event |
---|---|
2011-07-05 | New Permit Application |
2012-03-22 | Performed Spud Operation |
2012-08-02 | Drilling Completion |
2012-09-07 | Perforation |
2012-09-11 | Performed Stage 1 of Stimulation |
2012-09-12 | Perforation |
2012-09-12 | Performed Stage 2 of Stimulation |
2018-08-17 | Begin Plugging |
2018-09-28 | Finished Plugging |
2019-03-21 | Fully Plugged |
2019-03-21 | Newly Drilled |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-09-12 | 2012-09-12 | 7,008 | 159,578 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WFR-3B | Superior Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | |
Ethoxylated C12-16 alcohols | 68551-12-2 | 4.00 | 0.00313860 | |||||
1,2-Propylene glycol | 57-55-6 | 25.00 | 0.01 | |||||
Stoddard solvent | 8052-41-3 | 10.00 | 0.00784650 | |||||
Hydrochloric Acid | Superior Well Services | Cement/Formation Breakdown | Water | 7732-18-5 | 92.50 | 0.21 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.01 | |||||
ICP-1000 | Superior Well Services | Iron Control Additive | ANIONIC COPOLYMER | 50.00 | 0.00350290 | |||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00350290 | |||||
Super 100NE | Superior Well Services | Surfactant/Foamer | Isopropanol | 67-63-0 | 30.00 | 0.03 | ||
2-Butoxyethanol | 111-76-2 | 7.00 | 0.00751960 | |||||
CLAY TREAT LT | Superior Well Services | Clay Control | Choline chloride | 67-48-1 | 80.00 | 0.00037360 | ||
ACID INHIBITOR 2 | Superior Well Services | Acid Corrosion Inhibitor | Isopropanol | 67-63-0 | 0.00021020 | |||
2-Butoxyethanol | 111-76-2 | 0.00021020 | ||||||
PROPRIETARY | 0.00004900 | |||||||
Propargyl alcohol | 107-19-7 | 0.00021020 | ||||||
NO FOAM | Superior Well Services | Antifoam | Distillates, petroleum, hydrotreated heavy paraffinic | 64742-54-7 | 0.00050000 | 0.00000000 | ||
SUPER TSC | Superior Well Services | Scale Control | ANIONIC POLYMER | 10.00 | 0.00035030 | |||
ANIONIC COPOLYMER | 10.00 | 0.00035030 | ||||||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00175140 | |||||
1,2,4-Butanetricarboxylic acid, 2-phosphono- | 37971-36-1 | 10.00 | 0.00035030 | |||||
SUPER TSC | Superior Well Services | Paraffin & Scale Additive | ||||||
KR-153SL | Superior Well Services | Biocide | Polyethylene glycol | 25322-68-3 | 50.00 | 0.00175140 | ||
Ethylene glycol | 107-21-1 | 1.00 | 0.00003500 | |||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00070060 | |||||
Diethylene glycol | 111-46-6 | 3.50 | 0.00012260 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2012-09-11 | 1 | SAND | 159,578 | 5,687 | 5,986 |
2012-09-12 | 2 | SAND | 159,578 | 5,348 | 6,029 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SNYDER BROS INC | 18,290.00 | 71 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 40,196.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 27,317.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 16,248.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 14,370.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 9,128.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 4,552.00 | 243 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SNYDER BROS INC | Drill Cuttings | 109.00 Tons | ON SITE ENCAPSULATION | |
2012 | SNYDER BROS INC | Produced Fluid | 160.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 2,520.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012 | SNYDER BROS INC | Produced Fluid | 85.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012 | SNYDER BROS INC | Produced Fluid | 160.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2013 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
2013 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2016 | SNYDER BROS INC | Produced Fluid | 10.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2018 | SNYDER BROS INC | Produced Fluid | 120.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2018 | SNYDER BROS INC | Produced Fluid | 295.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2052840 | Primary Facility | 2012-03-22 | Routine/Complete Inspection | No Violations Noted | Site construction had been completed, drilling had not commenced. Drill pit located onsite and it was properly lined. The drill pit contained precipiation and it had more than the required two feet of lined freeboard. Erosion controls had been properly installed as outlined in the E&S plan located onsite. There was no observed acelerated erosion or sedimentation in relation to the access road or well-site. |
2054336 | Primary Facility | 2012-03-27 | Drilling/Alteration | No Violations Noted | WOC: repairing rig |
2056678 | Primary Facility | 2012-04-04 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed at the time of the inspection. Drill pit located onsite and it contained minimal fluids and more than the required two feet of lined freeboard. There was no accelerated erosion or sedimentation observed in relation to the access road or well-site. |
2080350 | Primary Facility | 2012-06-22 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed, well was not equipped for production. Drill pit located onsite and it had more than te required two feet of lined freeboard. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. All site and access road erosion controls had been implemented as outlined in the E&S plan. |
2108019 | Primary Facility | 2012-10-12 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed, well appeared to be equipped for production. There was no observed accelerated erosion or sedimenation in relation to the access road or well-site. Drill pit located onsite and the majority of the fluids had been removed leaving the drill cuttings. |
2142906 | Primary Facility | 2013-02-26 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Site had been regared and temporarily stabilized. The was no observed accelerated erosion or sedimentation in relation to the access road or well-site. The operator should continue to monitor the site to insure that the vegetative cover attains the minimum 70% uniform coverage. |
2360266 | Primary Facility | 2015-04-10 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. Site had been effectively restored and it was noted tha the was surrounded by cut cultivated crop fields. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2476468 | Primary Facility | 2016-04-19 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tank located onsite and it appeared to be in sound condition. It was noted that the well was located on an operating farm. |
2676522 | Primary Facility | 2018-01-02 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The annulus is open. The well head casing, production set equipment and 2 grounded 100 bbl fiberglass tanks look ok. |
2819938 | Primary Facility | 2018-12-27 | Site Restoration | No Violations Noted | Inspection conducted in response to a Post Plugging Site Restoration Report submitted by operator.
At time of inspection well, located in an ag field, appears to be plugged. No E and S issues observed. No temporary BMP's on site. Site appears to be returned to near original contours. No monument present. According to operator, a plate is buried below plow depth. This Restoration Report is approved. |
2829157 | Primary Facility | 2019-01-17 | Routine/Complete Inspection | No Violations Noted | On 1/17/19 at 1132 hrs., I conducted a routine inspection of Snyder Brothers, Inc.'s Robert E Patrick Jr 12M-197 well (API 005-30856) in. Mahoning Twp., Armstrong Co. This well has been plugged and the site has been restored for agricultural use. The well status is still listed as "Active" in eFacts. I requested that NWRO Oil & Gas staff change the well's status on 1/18/19. There are no violations noted for this inspection. |
For data sources see[9]