If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30878 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.764533,"lon":-79.513014,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Manor Township | |
Operator Name: MDS ENERGY DEV LLC | |
Well Pad ID: 146603 | |
Farm/Lease Name: JAMES A HELD ETUX 1M-25 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-09-16 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.764533 | |
Longitude: -79.513014 |
Date | Event |
---|---|
2011-09-16 | New Permit Application |
2012-09-12 | Performed Spud Operation |
2012-10-02 | Drilling Completion |
2012-10-09 | Perforation |
2013-05-28 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-10-09 | 2012-10-09 | 7,046 | 814,731 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Super TSC | Scale Control | 1,2,4-Butanetricarboxylic acid, 2-phosphono- | 37971-36-1 | ||||
Anionic Copolymer (proprietary) | ||||||||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00473000 | |||||
Acid Inhibitor-2 | Nabors Industries | Acid Corrosion Inhibitor | 2-Butoxyethanol | 111-76-2 | 30.00 | 0.00007000 | ||
Sand | Proppant | Quartz | 14808-60-7 | 99.90 | 7.96 | |||
Supermax | Surfactant/Foamer | 2-Butoxyethanol | 111-76-2 | 7.00 | 0.00070000 | |||
2-Ethylhexanol | 104-76-7 | 40.00 | 0.00400000 | |||||
Isopropanol | 67-63-0 | 30.00 | 0.00300000 | |||||
Proprietary | 7.00 | 0.00070000 | ||||||
Hydrochloric Acid 7.5 | Bulk Acid | Hydrochloric acid | 7647-01-0 | 7.50 | 0.00447000 | |||
Hydrochloric Acid 12.5-18 | Bulk Acid | Hydrochloric acid | 7647-01-0 | 16.00 | 0.02 | |||
ICP-1000 | Low Freeze Point Dispersant | 1,2-Propylene glycol | 57-55-6 | 50.00 | 0.01 | |||
Anionic Copolymer (proprietary) | 50.00 | 0.01 | ||||||
KR-153SL | Biocide | Diethylene glycol | 111-46-6 | 3.50 | 0.00053000 | |||
Polyethylene glycol | 25322-68-3 | 50.00 | 0.00753000 | |||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00301000 | |||||
Ethylene glycol | 107-21-1 | 1.00 | 0.00015000 | |||||
WFR-3B | Friction Reducer | 1,2-Propylene glycol | 57-55-6 | 25.00 | 0.01 | |||
Ethoxylated C12-16 alcohols | 68551-12-2 | 4.00 | 0.00275000 | |||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | |||||
Stoddard solvent | 8052-41-3 | 10.00 | 0.00688000 | |||||
Acid Inhibitor-2 | Acid Corrosion Inhibitor | Isopropanol | 67-63-0 | 30.00 | 0.00007000 | |||
Proprietary | 7.00 | 0.00002000 | ||||||
Propargyl alcohol | 107-19-7 | 30.00 | 0.00007000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | MDS ENERGY LTD | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | MDS ENERGY LTD | 2,840.00 | 14 | 0.00 | 0 | 0.00 | 0 |
2013 | MDS ENERGY LTD | 47,129.00 | 351 | 0.00 | 0 | 0.00 | 0 |
2014 | MDS ENERGY LTD | 29,291.00 | 354 | 0.00 | 0 | 0.00 | 0 |
2015 | MDS ENERGY DEV LLC | 21,189.00 | 348 | 0.00 | 0 | 0.00 | 0 |
2016 | MDS ENERGY DEV LLC | 18,005.00 | 351 | 0.00 | 0 | 0.00 | 0 |
2017 | MDS ENERGY DEV LLC | 15,948.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2018 | MDS ENERGY DEV LLC | 13,933.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2019 | MDS ENERGY DEV LLC | 12,266.00 | 360 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | MDS ENERGY LTD | Fracing Fluid Waste | 9,494.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012 | MDS ENERGY LTD | Produced Fluid | 84.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012 | MDS ENERGY LTD | Drilling Fluid Waste | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012 | MDS ENERGY LTD | Drilling Fluid Waste | 160.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2012 | MDS ENERGY LTD | Drilling Fluid Waste | 80.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 525-1 |
2012 | MDS ENERGY LTD | Drilling Fluid Waste | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2013 | MDS ENERGY LTD | Produced Fluid | 92.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23759 |
2013 | MDS ENERGY LTD | Produced Fluid | 160.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2013 | MDS ENERGY LTD | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2013 | MDS ENERGY LTD | Produced Fluid | 332.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2015 | MDS ENERGY DEV LLC | Produced Fluid | 120.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW009 |
2019 | MDS ENERGY DEV LLC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2019 | MDS ENERGY DEV LLC | Produced Fluid | 65.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2098710 | Primary Facility | 2012-09-11 | Routine/Complete Inspection | No Violations Noted | Site construction had been completed. All access road and site erosion controls had been properly implemented as outlined in the E&S plan and there was no evidence of accelerated erosion or sedimentation.. Well stimulation impoundment was still under construction and permiter controls for the area had been properly implemented. |
2104102 | Primary Facility | 2012-10-01 | Routine/Complete Inspection | No Violations Noted | Site construction had been completed, drilling was ongoing at the time of the inspection. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. After a phone conversation with the operator it was determined that the E&S plan for the well stimulation impoundment would be moved from near the impoundment to adjacent to the well pad E&S plan and site ID sign. |
2111745 | Primary Facility | 2012-10-26 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed, well appeared to be equipped for production. Final site grading was underway on the well pad. Freshwater impoundment located onsite and it contained minimal water. The access road, well pad and freshwater impoundment E&S controls appeared to be functioning properly and there was no observed evidence of accelerated erosion and/or sedimentation. |
2142883 | Primary Facility | 2013-02-26 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Well-site had been regraded and temporarily stabilized. No accelerated erosion or sedimentation was observed in relation to the site or access road. It was noted that a freshwater impoundment associated with this well was located onsite. The liner appeared to be intact and the impoundment contained miminal fluids. |
2201405 | Primary Facility | 2013-09-03 | Site Restoration | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Well-site had been regraded and stabilized. No accelerated erosion or sedimentation was observed in relation to the site or access road and the vegetative cover met the 70% uniform coverage criteria. |
2342836 | Primary Facility | 2015-02-10 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tanks located onsite and they appeared to be in sound condition. |
2511153 | Primary Facility | 2016-08-04 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tanks located onsite and they appeared to be in sound condition. |
2559045 | Primary Facility | 2017-02-02 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Annulus open. Well head casing-production set equipment-2 grounded 100 bbl fiberglass tanks looked ok. |
2705485 | Primary Facility | 2018-03-14 | Routine/Complete Inspection | No Violations Noted | At time of inspection, well is drilled and appears equipped for production. |
For data sources see[8]